14 SERVICING AND MAINTENANCE
56
Basic trouble shooting
If the truck does not work after action has been taken in
accordance with the following table, contact an authorised
service technician. Further action should only be carried out by
specially assigned and trained servicing technicians. If an error
code is shown on the diver's display, this must be reported to an
authorised service technician.
Truck condition
Possible cause
Procedure
The truck does not
start
The battery plug has
not been inserted
Insert the battery plug
The emergency stop
switch/battery
connector is not
connected
Connect the
emergency stop
switch/battery
connector
The battery capacity
is too low
Charge the battery
Fuse defective
Change the defective
fuse
The key switch is set
to "0" or the truck is
not logged on
Turn the key switch to
position "I" or enter
the appropriate
Operator ID and
password
Truck condition
Possible cause
Procedure
The truck cannot be
driven
The truck is not ready
for use
Carry out all the
actions under the
heading "The truck
does not work"
The driving seat
switch is not activated
Sit in the driving seat
P**/TS: Pull down the
tiller arm and stand
on the platform
Drive fuse defective
Change the defective
drive fuse
The truck will not lift
the load
The truck is not ready
for use
Carry out all the
actions under the
heading "The truck
will not start"
The driving seat
switch is not activated
PLP/TS: Stand on the
platform
The hydraulic oil level
is too low
Check the level and
top up the hydraulic
oil
The battery capacity
is below 20%
Charge the battery
Pump fuse defective
Change the defective
pump fuse
The load is too heavy Reduce the load
Refer to the maximum
permitted weight on
the machine plate