ELECTRICAL CONNECTIONS

6

Lift the front panel.
Take off the cover as indicated in the figure.
Connect the cable wires to the screw terminals by fol-
lowing the numbering.
Use  wire  size  suitable  to  the  electric  power  input  (see
name  plate  on  the  unit)  and  according  to  all  current
national safety code requirements.

Take the cover away.
Connect the cable wires to the terminal board using the
same numbering as in the indoor unit.
Fasten the cables with a cable-clamp.
Replace the covers again.

OUTDOOR UNIT

1

8

000 - 

24

000 BTU/h

INDOOR UNIT

1

8

000 - 

24

000 BTU/h

screw

Remove

the cover

1.
2.
3.

1.
2.

3.
4.

(1) ATTENTION: In case the outdoor unit has been installed higher than the indoor unit, it is necessary to provide “S” oil traps (or liquid separator)
to both refrigerant pipes, overy 

2

 m of difference in level.

MODEL

Liquid pipe diameter
Gas pipe diameter
Maximum lenght of pipe with standard charge
Maximum distance between indoor and outdoor unit
Additional gas charge
Maximum difference in level between indoor and outdoor unit (1)

Type of refrigerant

24

000 BTU/h

1/4”

5/8

5

 m

25

 m

2

0

 g/m

10

 m

R410A

1

8

000 BTU/h

1/4”

1

/

2

5

 m

25

 m

2

0

 g/m

10

 m

R410A

INFORMATION FOR THE INSTALLER

N.B.:

The unit must be connected to the power supply system through an onnipolar switch (3 mm distance). In case the power sup-

ply cable is damaged, it must be replaced by the manufacturer or qualified staff.

25 m

50

 

g/

m

Содержание MDUN 10H

Страница 1: ...INSTALLATION MANUAL MANUALE DI INSTALLAZIONE MDUN 10H MDUN 13H MDUN 18H MDUN 24H INVERTER SPLIT AIR CONDITIONER CLIMATIZZATORI D ARIA A PARETE INVERTER...

Страница 2: ...ER PIPING MOVING A SPLIT AIR CONDITIONER TO ANOTHER LOCATION REQUIRES SPECIAL TECHNIQUE IF NECESSARY CONSULT WITH THE SELLER wall type air conditioners inverter INSTALLATION MANUAL INSTALLATION ACCESS...

Страница 3: ...SELECTING THE INSTALLATION PLACE 1 insulating covering sleeve condensed water drain pipe electrical connections Do not install the outdoor unit near sources of heat steam or flammable gases Do not in...

Страница 4: ...d horizontally 2 Fix the bracket first with 5 screws 3 Use several more tapping screws to secure the bracket onto the wall with even pressure on the screws 4 Cut a hole in the wall for the piping and...

Страница 5: ...n pipes refrigerant pipe power cable 1 2 3 1 2 INDOOR UNIT CONDENSED WATER DRAINAGE 3 YES NO NO The indoor unit condensed water drainage is fundamental for the success of the installation Install the...

Страница 6: ...g the connection by using a fix wrench and a torque wrench in this case use the following table CONNECTIONS TO THE INDOOR UNIT Shape the connection pipe following the diagram Remove the indoor unit pi...

Страница 7: ...4 1 ATTENTION In case the outdoor unit has been installed higher than the indoor unit it is necessary to provide S oil traps or liquid separator to both refrigerant pipes overy 3 m of difference in l...

Страница 8: ...OOR UNIT TEST Do the ON OFF and FAN keys operate normally Does the MODE key operate normally Do the set point and TIMER keys function properly Does each lamp light normally Do the louvers for air flow...

Страница 9: ...1 ATTENTION In case the outdoor unit has been installed higher than the indoor unit it is necessary to provide S oil traps or liquid separator to both refrigerant pipes overy 2 m of difference in leve...

Страница 10: ...he ON OFF and FAN keys operate normally Does the MODE key operate normally Do the set point and TIMER keys function properly Does each lamp light normally Do the louvers for air flow direction operate...

Страница 11: ...UN CLIMATIZZATORE SPLIT DOPO CHE E STATO INSTALLATO E UN OPERAZIONE CHE RICHIEDE UNA SPECIFICA PREPARAZIONE NEL CASO SIA NECESSARIO CONSULTARE IL VOSTRO RIVENDITORE MANUALE INSTALLAZIONE ACCESSORI PE...

Страница 12: ...tro sia facilmente accessibile UNITA ESTERNA Non installare l unit esterna vicino a fonti di calore vapore o gas infiammabili Non installare l unit in luogo particolarmente ventoso o polveroso Non pos...

Страница 13: ...ti perfettamente in asse sia verticalmente che orizzontalmente 2 Fissare la dima inizialmente con 5 viti 3 Usare poi altre viti per fissare la dima al muro in modo uniforme su tutta la superficie 4 Fo...

Страница 14: ...solamento tubazioni tubazione frigorifera cavo di potenza 1 2 3 1 2 SCARICO DELLA CONDENSA DELL UNIT INTERNA 3 SI NO NO Lo scarico della condensa dell unit interna un punto fondamentale per la buona r...

Страница 15: ...lizzare la seguente tabella CONNESSIONI ALL UNIT INTERNA Sagomare i tubi di collegamento secondo il tracciato Togliere la calottina di chiusura dei tubi dell unit interna verificare che all interno no...

Страница 16: ...na sia stata installata ad un altezza superiore rispetto all unit interna necessario praticare dei sifoni o applicare dei separatori di liquido su entrambe le tubazioni ogni 3 metri di dislivello MODE...

Страница 17: ...TERNA I tasti ON OFF e FAN funzionano regolarmente Il tasto MODE funziona regolarmente I tasti per l impostazione del set point e del TIMER funzionano correttamente Si accendono tutte le spie Le alett...

Страница 18: ...stata installata ad un altezza superiore rispetto all unit interna necessario praticare dei sifoni o applicare dei separatori di liquido su entrambe le tubazioni ogni 2 metri di dislivello MODELLO Dia...

Страница 19: ...ionano regolarmente Il tasto MODE funziona regolarmente I tasti per l impostazione del set point e del TIMER funzionano correttamente Si accendono tutte le spie Le alette per l orientamento dell aria...

Страница 20: ...per le possibili inesattezze se dovute ad errori di trascrizione o di stampa Si riserva altres il diritto di apportare ai propri prodotti quelle modifiche che riterr necessarie o utili senza pregiudi...

Отзывы: