![Unical R 24 Скачать руководство пользователя страница 15](http://html2.mh-extra.com/html/unical/r-24/r-24_installation-and-servicing-manual_4839011015.webp)
15
Technical Features
ENGLISH
2.6 - DATA ACCORDING TO ErP DIRECTIVE
Description
Symbol
Unit
Model:
X
R24
C24
R32
C32
Nominal Heat Output
Pnominal
kW
23
31
Seasonal space heating energy
efficiency
ƞ
s
%
93
93
Seasonal efficiency class in
heating mode
A
A
For CH only and combination boilers: useful heat output
Useful Heat Output in high-tempera-
ture regime
(Tr 60 °C / Tm 80 °C)
P
4
kW
23,4
31,2
Useful efficiency at nom. heat output
in high-temperature regime
(Tr 60 °C / Tm 80 °C
ƞ
4
%
87,8
87,7
Useful heat output at 30% of nom.
heat output in low-temperature
regime (Tr 30 °C)
P
1
kW
7,8
10,4
Useful efficiency at 30% of nom. heat
output in low-temperature regime
(Tr 30 °C)
ƞ
1
%
97,9
97,8
Range-rated boiler: YES / NO
NO
NO
Auxiliary electricity consumption
At full load
elmax
kW
0,035
0,064
At part load
elmin
kW
0,013
0,012
In stand-by mode
P
SB
kW
0,003
0,003
Other items
Heat loss in stand-by
P
stb
kW
0,118
0,100
Emissions of nitrogen oxides ref. PCS
NOx
mg/kWh
45
49
NOx Class
6
6
Annual electricity consumption
Q
HE
GJ
73
97
Inside sound power level
Lwa
dB (A)
-
-
For CH & DHW production boilers
Declared load profile
-
XL
-
XL
Energy efficiency in DHW production mode
ƞ
wh
%
-
87
-
89
Daily electricity consumption
Qelec
kWh
-
0,10
-
0,09
Daily fuel consumptionl
Qfuel
kWh
-
22,45
-
21,9
Annual electricity consumption
AEC
kWh
-
404
-
403
Annual fuel consumption
AFC
GJ
-
17
-
17
Seasonal efficiency class
in DHW production mode
-
A
-
A