Installation Instructions
3.12.1 - COMBUSTION ADJUSTMENT FUNCTION ACTIVATION
1
ACTIVATION
Press the keys (
B- and B+
) at the same time for
at least 10 seconds, SErvice APPEARS.
CO ...scrolls on the display
MAXIMUM OUTPUT
When the display alternates CO - 100
This function allows a partial adjustment of the
CO
2
value on the following modulation points:
Maximum output
100 %
Start-up output
xx %
Minimum output
0 %
EDITING THE VALUE
When the flame flashes, correct the value with
keys
C-
or
C+
VALUES
FROM
TO
DEFAULT
-3 *
+3 *
0
(*) corresponds to about ± 0.5 points of CO
2
SELECTION
Select the modulation point on which to perform
the adjustment, (max output / start-up output / min
output) with key
B+
Press key
S
3
2
DISABLING
Press the keys (
B- and B+
) at the same time for
at least 10 seconds, SErvice DISAPPEARS.
5
START-UP OUTPUT
When the display alternates CO - with value XX.
MINIMUM OUTPUT
When the display alternates CO - 0
4 CONFIRM VALUE
Press key
D
The flame is fixed
again.
4