Unical HP_OWER 250N Скачать руководство пользователя страница 7

HP_OWER

 

 

5

 

AVAILABLE VERSIONS, SIZES AND ACCESSORIES 

 

Model 

Description 

Standard configuration code 

HP_OWER 250 

Size 25 kW  

00269135 

HP_OWER 350 

Size 35 kW  

00268661 

HP_OWER 500 

Size 50 kW  

00269137 

Name of factory-fitted accessories: 

 

CODE  

Descrizione 

NAME 

00264032/33 

High efficiency integrated circulator 

CI 

00264035 

Antifreeze kit 

KA 

00264034 

Management plant module 

GI 

00264038 

KIT SLN Super silencing 

SLN 

5.1

 

OPTIONAL ACCESSORIES 

Touch-

screen 

Multifunction touch screen remote control with centralized management, functions of USB port, temperature and 

humidity sensors. It has also an extremely intuitive interface simplifying the use of the controller. 

LN 

Silence kit for compressor 

AG 

Anti-vibration rubber pad to be installed in the chassis of the unit for possible shock absorption. 

 

IMPORTANT NOTE 

ONLY THE OPTIONAL ACCESSORIES CAN BE REQUIRED AFTER THE ORDER OF THE UNIT, 

WHILE THE FACTORY INSTALLED ACCESSORIES CAN NOT BE REQUIRED AFTER THE ORDER OF THE UNIT.

 

6

 

INSTALLATION 

 

WARNING: All the operation described in next chapters MUST BE DONE BY TRAINED PEOPLE ONLY. Before any 

operation on the unit, be sure that the electric supply is disconnected. 

6.1

 

GENERALITY 

When installing or servicing the unit, it is necessary to strictly follow the rules listed in this manual, to conform to all the 

specifications of the labels on the unit, and to take any possible precautions. Not observing the rules reported on this manual can 

create dangerous situations. 

 

After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any eventual 

damage has to be questioned to the carrier and recorded on the Delivery Note before signing it. 

The company has to be informed, within 8 days, of the extent of the damage. The Customer should prepare a written statement of 

any severe damage.  

 

WARNING:  The units are designed for outdoor installation and for places not directly accessible to unqualified 

personnel. The place of installation must be entirely far away from fire risk. All the necessary measures should be 

adopted in order to prevent the fire risk in the place of installation. The outdoor ambient temperature shall not 

exceed 46°C. Above this value, the unit is no longer covered by the directives in force in the area of pressure 

equipment. 

 

WARNING: The unit should be installed so that adequate clearance is available for maintenance and repairation. The 

warranty does not cover costs related to platforms or handling equipment necessary for any maintenance. 

 

All maintenance and testing operations should be carried out only by QUALIFIED PERSONNEL. 

 

Before any operation on the unit, make sure the power supply is disconnected. 

 

WARNING: MOVING PARTS, RISK OF DEATH. 

Disconnect the power supply and ensure that the fan is stopped before opening the front panel. 

 

The top part and discharge pipes of the compressor operates at high temperatures. Be sure to let the unit to become 

cool before beginning any maintenance work. 

 

Be careful when working near condensing coils. 

The aluminum fins are very sharp and can cause serious injuries. 

 

After the maintenance operations, close the panels tightly with the fastening screws. 

Содержание HP_OWER 250N

Страница 1: ...User s and Installer s Manual 250 350 500 N...

Страница 2: ...optional module terminal block CODE 00264034 13 7 START UP 14 7 1 POWER ON OF THE UNIT 14 8 INDICATIONS FOR THE USER 14 9 SHUTDOWNS FOR LONG PERIODS 14 10 MAINTENANCE AND PERIODICAL CONTROLS 15 10 1...

Страница 3: ...unit it refers to It has to be stored in a safe place away from the dust and moisture It has to be accessible to all users who shall consult it any time they are in doubt on how to operate the equipm...

Страница 4: ...well as any applicable local laws and authorized specifications The execution of all works must be performed by skilled and qualified personnel competent in the existing rules in different countries T...

Страница 5: ...ce s health and safety including 89 391 CEE 89 686 CEE 89 655 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such norms and ensure that workers to respect them It...

Страница 6: ...TWA 1000 ml m for each of the two components Respiratory protection For rescue and maintenance operation in storage tanks use self contained respirator The vapors are heavier than air and can cause su...

Страница 7: ...ng the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be questioned to the carrier and recorded on the Delivery Note before signing it T...

Страница 8: ...rubber band between basement and unit base frame It is also possible to install anti vibration supports springs or rubbers to keep vibrations at a very low level An absolute care has to be taken to en...

Страница 9: ...ing water for the plant please refer to UNI 8065 CAUTION The INVERTER control system is able to manage minimum water contents in the plant up to a value of 75 liters for the model HP_OWER 250 of 105 l...

Страница 10: ...R 4WV CYCLE REVERSING VALVE LR LIQUID RECEIVER EEV ELECTRONIC EXPANSION VALVE FL FILTER M AXIAL FAN SE OUTDOOR AIR TEMPERATURE SENSOR P CIRCULATOR ON BOARD UNIT IN WATER INLET TEMPERATURE OUT WATER OU...

Страница 11: ...must be installed in TN S TT power supply grounding systems The electrical installation must be carried out in accordance with norms in force WARNING The supply voltage s fluctuations cannot exceed 5...

Страница 12: ...utral conductor N 6 6 2 User s terminal block L1F1 L1F1 L2F1 L2F1 L3F1 L3F1 N 1 N 2 N 1 N 2 PE 1 PE 1 L3 1 L3 2 L3 1 L3 2 HPS HPS 12AC1 12N1 12AC1 12N1 DO1 DO3 DO5 DO4 DO6 DO7 DO2 DO7N DO6N DO5N DO4N...

Страница 13: ...the unit s front panel For the configuration of the functionalities please check the control manual supplied with the unit DO1E DO3E DO5E DO4E ST5E ST6E DO2E DO1EN DO1EN DO1E DO3E DO5E DO4E ST5E ST6E...

Страница 14: ...hanges of this seasonal operating mode have to be avoided in order to prevent severe damages to compressors WARNING When you first install and start up the unit make sure that the unit is working prop...

Страница 15: ...entering the inner components of the unit be sure that the power supply is disconnected The compressor s heads and discharge pipes are usually at high temperature levels Be very careful when operating...

Страница 16: ...rolled substances and for this reason it has to be subjected to the mentioned norms A particular care is recommended during service operations in order to reduce as much as possible any refrigerant lo...

Страница 17: ...0 27 04 29 1 36 21 38 4 36 36 38 3 Power input 2 kW 6 48 6 35 9 1 8 96 12 49 12 45 EER 2 W W 3 24 3 33 2 96 3 02 2 90 2 92 SEER 5 W W 3 98 4 00 4 03 Heating Heating capacity 3 kW 24 72 27 2 24 57 27 2...

Страница 18: ...70 dB A 74 dB A 77 dB A Precautions for installation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual PRODUCT FICHE HP_OWER f...

Страница 19: ...5 94 Tj bivalent temperature Pdh 16 4 kW Tj bivalent temperature COPd 2 36 Tj operation limit temperature Pdh 13 8 kW Tj operation limit temperature COPd 1 76 For air to water heat pumps Tj 15 C if T...

Страница 20: ...89 Tj bivalent temperature Pdh 20 5 kW Tj bivalent temperature COPd 2 12 Tj operation limit temperature Pdh 17 7 kW Tj operation limit temperature COPd 1 83 For air to water heat pumps Tj 15 C if TOL...

Страница 21: ...5 76 Tj bivalent temperature Pdh 31 4 kW Tj bivalent temperature COPd 2 23 Tj operation limit temperature Pdh 26 6 kW Tj operation limit temperature COPd 1 73 For air to water heat pumps Tj 15 C if TO...

Страница 22: ...W Tj 12 C COPd 3 68 Tj bivalent temperature Pdh 11 6 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 9 8 kW Tj operation limit temperature COPd 1 56 For air to water heat pumps...

Страница 23: ...W Tj 12 C COPd 3 88 Tj bivalent temperature Pdh 20 7 kW Tj bivalent temperature COPd 1 59 Tj operation limit temperature Pdh 17 6 kW Tj operation limit temperature COPd 1 33 For air to water heat pump...

Страница 24: ...W Tj 12 C COPd 3 51 Tj bivalent temperature Pdh 23 0 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 19 6 kW Tj operation limit temperature COPd 1 56 For air to water heat pump...

Страница 25: ...with the UNI EN ISO 9614 2 13 ELECTRIC DATA OF THE UNIT AND AUXILIARIES Power supply of the unit V Hz 400 3 50 Remote control circuit V Hz 12 1 50 Control board circuit V Hz 12 1 50 Fans power supply...

Страница 26: ...ve circulator with the possibility of choice between constant P and variable P 15 2 MODEL HP_OWER 500N Configuration with integrated circulator control via 0 10 volt analogic signal Configuration with...

Страница 27: ...SS CURVES OF THE HYDRONIC CIRCUIT We obtain the pressure head of the circulating pump from the addition of the head losses of the hydronic circuit and the available head pressure For example for the m...

Страница 28: ...rmal insulation which reduces at very low outside temperatures the heat losses of 2 compared to a standard insulation 18 2 SSL Cod 00264038 The super silenced unit with SLN accessory is provided not o...

Страница 29: ...lity study and evaluation of changes to be made according to your requests The maximum temperature that can be maintained at the outlet of the evaporator is 25 C Higher temperatures up to a maximum of...

Страница 30: ...ssure drops correction factor The water flow rate and pressure drop correction factors are to be applied directly to the values given for operation without glycol The water flow rate correction factor...

Страница 31: ...Max Packing height mm Max Packing height with AXITOP Versions SSL mm HP_OWER 250N 350N 1673 1906 1785 2030 HP_OWER 500N 1745 1910 1890 2055 Some units could be shipped with another type of packaging...

Страница 32: ...he units is indicative and useful to present the main components and can therefore vary from the purchased one The front panel is closed The front panel is open at 180 Disconnecting switch with door l...

Страница 33: ...n models there are also other components installed in an additional plate at the bottom left side of the electric box On board terminal block and user s terminal block Support boards Transformer Drive...

Страница 34: ......

Страница 35: ......

Страница 36: ...s It also reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova italia tel 39 0376 57001 fax 39 0376 660556 in...

Отзывы: