2.2.15 - ELECTICAL CONNECTIONS
The electrical connections of Logamax are
shown in the clause ‘’WIRING DIAGRAMS’’
(par. 2.3 - pag. 24)
The boiler must be connected to
the mains supply at
230 V - 50 Hz
. This connection is
to be perfectly done, as foreseen
by the IEC and local rules and must be ear-
thed.
This fundamental requirement for safety pur-
poses must be checked; in case of doubt,
ask for a professionally qualified technician
to check the electrical system.
UNICAL
disclaims all liability for damage or
injury caused by failure to earth the system
properly.
Gas, domestic water and central heating
pipes are not suitable for earthing purpo-
ses.
The boiler is supplied with 1.5 m long
3x0,75mm² cord.
A double pole switch with a distance between
the contacts higher than 3 mm, must be in-
stalled upstream the boiler to enable all main-
tenance operations to be carried out safely.
Access to the electrical terminal strip
-
WARNING! Switch off the electrical sup-
ply
-
Remove the casing.
-
Remove the four screws
(A)
and the cover
(B)
in order to get access to the connec-
tions area.
Replacement of the feeding cord
Should the feeding cord be replaced, you have
to use the original cable code
00610308.
-
Approach the feeding connector Y2.
-
Introduce the feeding cord through the ex-
tractable cable clamp.
-
Extract the connector Y2 and proceed with
the connections according to the positions
and to the colours. The female faston of
the earth wire must be introduced in the
male faston GND1.
Connection of the ON/OFF room thermo-
stat (RT)
-
Approach the connector Y1.
-
Remove the existing jumper and connect,
on its place the room thermostat cable,
passing it through one of the cable clam-
ps avaible.
Connection of the room modulating ther-
mostat (OT)
-
Approach the connector Y1.
-
Connect the room thermostat cable, pas-
sing it through one of the cable clamps
avaible.
-
The modulating chronothermostat is to be
connected exactly to the same terminal of
the ON/OFF room thermostat; in this case
the jumper JP2 has to be changed of posi-
tion (see. par 2.3.2).
For a multi-zones temperature control it is not
possible to install the modulating chronother-
most.
Example:
At 25°C, the nominal resistance is 10067 Ohm
At 90°C, the nominal resistance is 920 Ohm
Relation between the temperature (°C) and nominal resistance (Ohm)
of the heating sensor SR and D.H.W. sensor SS
TABLE OF RESISTANCE VALUES AS A FUNCTION OF THE TEMPERATURE
OF THE HEATING SENSOR (SR) AND D.H.W. SENSOR (SS)
T°C
0
1
2
3
4
5
6
7
8
9
0
32755
31137
29607
28161
26795
25502
24278
23121
22025
20987
10
20003
19072
18189
17351
16557
15803
15088
14410
13765
13153
20
12571
12019
11493
10994
10519
10067
9636
9227
8837
8466
30
8112
7775
7454
7147
6855
6577
6311
6057
5815
5584
40
5363
5152
4951
4758
4574
4398
4230
4069
3915
3768
50
3627
3491
3362
3238
3119
3006
2897
2792
2692
2596
60
2504
2415
2330
2249
2171
2096
2023
1954
1888
1824
70
1762
1703
1646
1592
1539
1488
1440
1393
1348
1304
80
1263
1222
1183
1146
1110
1075
1042
1010
979
949
90
920
892
865
839
814
790
766
744
722
701