5.3 -
DISPLAY OF ERROR CODES ON E8
HEATING CONTROLLER
E 13
E 14
E 32
E 2
E 15
24
18
12
6
If a fault or error occurs in the heating system a blinking warning
triangle and the related error code will appear on the E8 display.
The boiler’s error codes, relative description and corrective
actions are listed here below.
For the error codes relative to the heating system please refer
to the paragraph “Fault finding” in the “Users guide” supplied
together with the heating controller E8.5064 V1.
Code:
Description:
Alteration of the factory parameters caused by
electromagnetic disturbances
Corrective action:
Restore the factory parameters
Code:
Description:
Flame detected before the start of the ignition
cycle
Corrective action:
emove detection electrode wiring from the control
board; if the error code disappears replace wiring,
otherwise replace the control board
Code:
Description:
Flame detected after burner off
Corrective action:
Remove gas valve wiring from the control board;
if the error code disappears replace the control
board otherwise replace the gas valve
Code:
Description:
Internal failure
Corrective action:
Replace the control board
Ensure that the appliance is serviced and subsequently reset
the counter to zero by selecting the text “Cr” from the parame-
ter menu and entering the relative unblocking code.
The boiler is equipped with an integrated system which, after
10,000 ignitions or 2.000 hours of burner operation, signals
that the boiler has to be serviced.
This request is identified when the code
appears on the
display.
Note:
The code flashing will not impede the boiler
to operate normally
5.2 - SERVICING REQUEST
Description:
DHW sensor failure (SS)
Corrective action:
Check the sensor’s efficiency and/or its wiring
Description:
Mains supply < 190 Vac
Corrective action:
Corrective action: Check that the mains supply is
< 190Vac. If the mains supply is correct replace
the control board.
Description:
Insufficient gas pressure
Corrective action:
Check the pressure, if the pressure is correct
control the gas switch and/or its wiring.
Description:
Difference between the temperature of the CH
sensor (SR) and the temperature of the heating
return sensor (SRR) > 35°C.
Corrective action:
Examine the system.
Description:
Failure of the heating return sensor (SRR)
Corrective action:
Corrective action: Check the efficiency of the
sensor and/or its wiring