10
Technical features and dimensions
24 C
II
2H3P
1,7
0,5
3
2,2
85
30
6
1
111
2
0,5
6
11,2
12
7,34
8,26
9,44
11,0
13,2
38-60
230/50
4
132
X4D
36
24 R
II
2H3P
1,7
0,5
3
2,2
85
30
6
1
111
-
-
-
-
-
-
-
-
-
-
-
230/50
4
132
X4D
33
18 C
II
2H3P
1,31
0,5
3
2
85
30
6
1
111
2
0,5
6
8,8
12
5,7
6,4
7,3
8,6
10,3
38-60
230/50
4
120
X4D
36
18 R
II
2H3P
1,7
0,5
3
2,2
85
30
6
1
111
-
-
-
-
-
-
-
-
-
-
-
230/50
4
120
X4D
33
l/min
bar
bar
l
°C
°C
l
bar
l
l/min
bar
bar
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
°C
V-Hz
A (F)
W
IP
kg
(*) mixed
MODELLO
kW
kW
kW
kW
%
%
n.
kW
kW
%
%
%
%
%
%
°C
g/s
%
kg/h
%
mg/kWh
mg/kWh
%
%
MODEL
R 24
23,8
4,4
23,0
4,2
96,47
95,19
4
24,0
4,71
100,92
107,13
97,19
98,11
0,7
0,452
58,2
10,43
20,57
3,83
-
20 - 133
38,8
5
2,8
C 18
18,0
4,4
17,4
4,2
96,63
95,19
4
18,4
4,71
102,08
107,13
97,57
98,11
0,9
0,452
50,3
7,89
20,57
2,9
-
20 - 90
35,5
5
2,4
R 18
18,0
4,4
17,4
4,2
96,63
95,19
4
18,4
4,71
102,08
107,13
97,57
98,11
0,9
0,452
50,3
7,89
20,57
2,9
-
20 - 90
35,5
5
2,4
C 24
23,8
4,4
23,0
4,2
96,47
95,19
4
24,0
4,71
100,92
107,13
97,19
98,11
0,7
0,452
58,2
10,43
20,57
3,83
-
20 - 133
38,8
5
2,8
Appliance’s family gas category
Min. water flow rate in CH circuit (
Δ
t 35°C)
Min. pressure in CH circuit
Max. pressure in CH circuit
Water content in primary circuit
Max operating temp. in CH mode
Min operating temp. in CH mode
Total volume CH expansion vessel
Total pre-loading expansion vessel
Max water content CH circuit (calculated for a max temp. of 90°C)
Min flow rate DHW circuit
Min. DHW inlet pressure
Max DHW inlet pressure
DHW specific flow rate (
Δ
t 30°C)
DHW flow restrictor
DHW production in continuous operation with
Δ
t 45 K
DHW production in continuous operation with
Δ
t 40 K
DHW production in continuous operation with
Δ
t 35 K
DHW production in continuous operation with
Δ
t 30 K (
*
)
DHW production in continuous operation with
Δ
t 25 K (
*
)
DHW adjustable temperature
Electrical supply /power consumption
Fuse rating
Maximum absorbed power
Electrical protection
Net weight
2.6 - GENERAL FEATURES
2.5 - PERFORMANCE DATA ACCORDING TO STANDARD UNI 10348
For information regarding the adjustment of: INJECTORS - BURNER PRESSURES – DIAPHRAGMS – OUTPUTS – GAS CONSUMPTIONS please refer to the paragraph
BURNER PRESSURE ADJUSTMENT
.
Max heat input
Min heat input
Nominal heat outpout
80/60
Minimum heat output
80/60
Efficiency at nominal load
80/60
Efficiency at minimal load
80/60
Number of stars (according to CEE 92/42)
Nominal heat output in condensing mode 50/30
Minimal heat output in condensing mode 50/30
Efficiency at nominal load in condensing mode
50/30
Efficiency at minimal load in condensing mode
50/30
Combustion efficiency at full load (100%)
Combustion efficiency at reduced load
Losses with burner in operation
Losses with burner off
(*)
Flue gas temperature tf-ta (max)
Flue gas mass flow rate (min-max)
Air excess
λ
Condensate production max
(**)
CO
2
(min.-max)
CO
at
0% of O
2
(min - max)
N0x (value according to EN 297/A3 and EN 483)
N0x class
Flue losses with burner in operation (max)
Technical data registered with the appliance operating with natural gas (G20)
(*) Room Temperature = 20°C
(**) See Table Injectors - Pressures
Содержание ALKON C 18
Страница 1: ...ALKON 09 R 18 C 18 R 24 C 24 00333176 2nd edition 10 2011 INSTALLATION AND SERVICING MANUAL ...
Страница 46: ......
Страница 47: ......