User’s operating instructions

Cause:

Insufficient water pressure in the central heating system.

Elimination of the fault:

Restore the correct pressure value by regulating the boiler’s

filling valve (for correct boiler operation the pressure should

be between 0,8 and 1 bar).

When the correct pressure value has been reached the led

will switch off automatically and normal boiler operation will

be restored.

DANGER!

If the system has to be frequently restored

please contact an authorized Unical After

Sales Service Centre.

6.5 - ELIMINATING THE FAULTS

If the boiler goes into lock-out the user can reset the boiler

only in the following cases:

Lock-out led illuminated and flashing

WARNING:

If the boiler goes into lock-out and/or the

leds continue to flash repeatedly or remain

illuminated do not try to reset the boiler your-

self. Contact your nearest Unical authorized

Afters Sales Service Centre.

Burner lock-out  led constantly illuminated

Open

Filling

cock

Close

Cause:

IThe burner’s lock-out device has intervened due to:

- no  gas supply (in this case check that the gas service cock

is open

- presence of air in the piping (if it is a new system or after a

long inactivity of the boiler).

Elimination of the fault:

Check that the gas service cock is in the On position and that

the air  present in the piping has been vented.

Press the reset key to restore correct boiler operation.

If the cut-off device operates repeatedly  (a

maximum of 3 times), causing boiler shu-

tdown, do not try to relight the boiler your-

self. Contact your nearest Unical authorized

After Sales Service Centre.

Содержание ALKON 35S C

Страница 1: ...00333170 2nd edition 09 2012 USER SOPERATING INSTRUCTIONS English ALKON 35S R 35S C Adjusted for 28 kW 35S R 35S C 35S R Adjusted for 25 kW...

Страница 2: ...to carefully follow the instructions indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water a...

Страница 3: ...held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must b...

Страница 4: ...hea ting temperature control When the switch is in the Summer position the central heating mode is exclu ded However the frost protection mode remains enabled With the knob in the position indicated...

Страница 5: ...en it will be necessary to restore the cor rect pressure by operating the filling valve when the system is cold and the boiler not operating Power On indicator led This led will illuminate when the bo...

Страница 6: ...tomatically when the system temperature falls be low6 C the burner is automatically fired and the pump is ener gized until the system s water temperature has risen to 16 C If the temperature detected...

Страница 7: ...If the boiler goes into lock out and or the leds continue to flash repeatedly or remain illuminated do not try to reset the boiler your self Contact your nearest Unical authorized Afters Sales Servic...

Страница 8: ...transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics AG S P A 46033 casteldar...

Отзывы: