Unical ALKON 35S C Скачать руководство пользователя страница 5

5

User’s operating instructions

Reset key with “Chimneysweeper” mode

WARNING!

This operation can be carried out exclusi-

vely by personnel from authorized After Sa-

les Service centres. The user is NOT autho-

rized to activate the following described

mode.

By pressing this key the “Chimneyswee-

per” mode is activated. This means that

the boiler will be forced to operate at the

maximum (or minimum) output so as to

permit the adjustment operations and the

combustion analysis.

By pressing this key for at least 3 seconds

the boiler will operate at the maximum ou-

tput (led 

D

 = illuminated and flashing and

led 

E

 = constantly illuminated).

By briefly pressing this key again (<3 secs.),

the boiler will operate at the minimum ou-

tput (both the leds 

D

 and 

E

 flashing).

The “chimneysweeper” mode will remain enabled for 15 minu-

tes.

To disenable the 

“CHIMNEYSWEEPER”

 mode before this set

time has elapsed, press the reset/chimneysweeper key 

“G”

for at least 3 seconds.

System temperature control/pressure gauge

This displays:

- on the upper scale the central heating

hot water flow temperature is indicated.

- On the lower scale the water pressure

in the central heating system is indica-

ted.

- If the pressure is lower then 0,7 bar, then

it will be necessary to restore the cor-

rect pressure by operating the filling

valve when the system is cold and the

boiler not operating.

Power On indicator led

This led will illuminate when the boiler is connected to

the electricity supply

Central heating mode indicator led

This led will illuminate when there is a request for cen-

tral heating. If simultaneously there is a request for

domestic hot water production, the led will switch off.

Burner On indicator led

When this led is illuminated it indicates that the burner is

functioning correctly, both in central heating request

mode and in domestic hot water production mode.

“RIRA” pre-heating function

If this function is enabled it will ensure an

immediate supply of domestic hot water.

- This function is enabled if the led (green)

is illuminated.

- This function is 

disenabled

 if the led (gre-

en) is switched off.

To enable/disenable the 

RIRA

 function

press the appropriate key.

Lock-out indicator led

When this led is illuminated it indicates that the burner’s

safety cut-off device has shut-down the boiler.

Reset key

The function of this key is to reset correct boiler ope-

ration after the cut-off device has shutdown the boi-
ler (red   led indicator illuminated)

If the cut-off device operates more than 3

times, causing boiler shutdown, do not try

to reset the boiler yourself. Contact your

nearest Unical authorized After Sales Servi-

ce Centre.

Содержание ALKON 35S C

Страница 1: ...00333170 2nd edition 09 2012 USER SOPERATING INSTRUCTIONS English ALKON 35S R 35S C Adjusted for 28 kW 35S R 35S C 35S R Adjusted for 25 kW...

Страница 2: ...to carefully follow the instructions indicated in this guide 3 WATER TREATMENT The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned In hard water a...

Страница 3: ...held liable for any such injury and or damage 4 INFORMATION TO BE HANDED OVER TO THE USER BY THE INSTALLER 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must b...

Страница 4: ...hea ting temperature control When the switch is in the Summer position the central heating mode is exclu ded However the frost protection mode remains enabled With the knob in the position indicated...

Страница 5: ...en it will be necessary to restore the cor rect pressure by operating the filling valve when the system is cold and the boiler not operating Power On indicator led This led will illuminate when the bo...

Страница 6: ...tomatically when the system temperature falls be low6 C the burner is automatically fired and the pump is ener gized until the system s water temperature has risen to 16 C If the temperature detected...

Страница 7: ...If the boiler goes into lock out and or the leds continue to flash repeatedly or remain illuminated do not try to reset the boiler your self Contact your nearest Unical authorized Afters Sales Servic...

Страница 8: ...transcript or press Also reserves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics AG S P A 46033 casteldar...