background image

Unic International (UK)

Health & Safety Data Sheet

Information supplied in accordance with section 6 of the health and safety at work etc. Act 1974

PRODUCT NAME

UNIC POWERCLEAN SPRAY GUN CLEANING UNIT.

USES

Removal of paint from Spray guns, cups and hoses.

GENERAL

Before operating Powerclean Spray Gun Cleaning System, operators must be

PRECAUTIONS

familiar with the correct operating procedures as detailed in the manufacturer’s
Operating Manual.

Do not tamper with the safety lid switch, which prevents the unit operating in the
cleaning mode when the lid is open.

Close drain valve and close lid when the unit is not in use. All solvent should be
drained from the cleaning tank before closing the drain valve.

Inspect solvent storage compartment daily to ensure there is no leaks from the
solvent containers.

Replace solvent filter pad frequently (bimonthly replacement of the filter pad is
recommended)

Always disconnect the air source before performing maintenance tasks.

FIRE HAZARDS

Do not smoke or use other ignition sources near the cabinet.
E.g. no hot work, such as welding.

HEALTH HAZARDS

The cleaning solvent used will contain substances hazardous to health, typically
acetone, methanol, white spirit, xylene and toluene. Air monitoring carried out
with a recommended cleaning thinner has shown that concentrations do not
exceed exposure limits published by the Health and Safety Executive. Levels
were less than 50% of the mixed short-term exposure limit when the lid was
open for removal of the spray gun, cups and hoses and just 6% of the limit
during the cleaning cycle. Substances in the solvent however can be absorbed
through the skin, see personal protection equipment.

VENTILATION

A local exhaust ventilation system as supplied with the machines, should be
installed so that vapours are safely vented to atmosphere away from windows
and other air inlets. In accordance with the Control of Substances Hazardous to
Health regulations 1988 the system should be maintained and undergo a
thorough examination.

PERSONAL

Suitable gloves must be worn when replacing and removing spray guns from the

PROTECTION

cleaning machine. Most glove manufacturers recommend Nitrile gloves for the

EQUIPMENT

solvent xylene and toluene, which can be absorbed through the skin.

WASTE DISPOSAL

Waste solvent must be removed by a registered carrier to a disposal or recovery
facility licensed to receive waste solvent.

EMERGENCY

FIRE

ACTION

In case of fire, use a form of dry powder extinguishing agent. Cool solvent drums
exposed to fire with water spray.

FIRST AID
Eye contact with solvent- irrigate with clean water. Skin contact with solvent-
remove contaminated clothing, wash skin thoroughly with soap and water.

Excess inhalation of solvent vapours – Remove to fresh air, seek medical
attention

Accidental Ingestion – Do not induce vomiting, seek medical attention.

SPILLAGE OF SOLVENT
Contain and collect with non-combustible materials E.g. sand and earth. Do not
allow to enter drains. Exclude sources of ignition. Ventilate area.

SUPPLIER

Unic International (UK)

INFORMATION

Colwick Road, Nottingham NG2 4BG
Tel +44 (0) 115 947 4000
Fax +44 (0) 115 950 6666

Содержание UGC2006M

Страница 1: ...ngs We also recommend I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Solvent Based Spray Gun Cleaner Operating Instructions UGC2006M UGC2006 UGC4006 UGC5006 786 Air Dirt Water t...

Страница 2: ...re Hose and a range of adaptors are available direct from Unic International Connect the machine to the air supply All air connections are located on the right hand side of the machine when viewed fro...

Страница 3: ...f solvent and enter drain tube Push solvent container s under machine aligning filler neck with male part of quick release coupling Reconnect quick release coupling UGC4006 UGC5006 ONLY Place the full...

Страница 4: ...y 4 minutes Upon completion open the lid and remove the spray guns from the machine We advise that you DO NOT store the spray guns in the machine MANUAL WASH CLEAN RINSE UGC4006 and UGC5006 For UGC200...

Страница 5: ...e lid was open for removal of the spray gun cups and hoses and just 6 of the limit during the cleaning cycle Substances in the solvent however can be absorbed through the skin see personal protection...

Страница 6: ...ppm 10 min TWA detection Propan 2 OL 500 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Propyl Acetate 250 ppm Less than limit of Less than limit of Not measured...

Страница 7: ...nized standards Certified to Atex standards Certificate number SIRA 03ATEX5252 EC Notified Body not applicable Approved By Date Director Signed Date Director Printed I N T E R N A T I O N A L T h e p...

Страница 8: ...turing 2013 14 Height 1525mm Width 526mm Depth 400mm Weight 47kg Directive 94 9 EC Marking Ex II 2G T6 Certificate Number SIRA 03ATEX5252 Model UGC4006 Air Input 40 90 PSI 2 75 6 Bar Air Consumption 1...

Страница 9: ...A L T h e p r o f e s s i o n a l s c h o i c e Information Request Form FAX BACK 44 0 115 950 6666 Please send information on please tick appropriate box Mini Spray Gun Cleaners Can Crushers Paint Ca...

Страница 10: ...s as to the storage installation commissioning use or maintenance of the Machine or if there are none good trade practice or d the Buyer alters or repairs the Machine other than by replacing consumabl...

Отзывы: