Health & Safety Data Sheet

Information supplied in accordance with section 6 of the health and safety at work etc. Act 1974

PRODUCT NAME

UNIC POWERCLEAN SPRAY GUN CLEANING UNIT.

USES

Removal of paint from Spray guns, cups and hoses.

GENERAL

Before operating Powerclean Spray Gun Cleaning System, operators must be

PRECAUTIONS

familiar with the correct operating procedures as detailed in the manufacturer’s
Operating Manual.

Do not tamper with the safety lid switch, which prevents the unit operating in the
cleaning mode when the lid is open.

Close drain valve and close lid when the unit is not in use. All solvent should be
drained from the cleaning tank before closing the drain valve.

Inspect solvent storage compartment daily to ensure there is no leaks from the
solvent containers.

Replace solvent filter pad frequently (bimonthly replacement of the filter pad is
recommended)

Always disconnect the air source before performing maintenance tasks.

FIRE HAZARDS

Do not smoke or use other ignition sources near the cabinet.
E.g. no hot work, such as welding.

HEALTH HAZARDS

The cleaning solvent used will contain substances hazardous to health, typically
acetone, methanol, white spirit, xylene and toluene. Air monitoring carried out
with a recommended cleaning thinner has shown that concentrations do not
exceed exposure limits published by the Health and Safety Executive. Levels
were less than 50% of the mixed short-term exposure limit when the lid was
open for removal of the spray gun, cups and hoses and just 6% of the limit
during the cleaning cycle. Substances in the solvent however can be absorbed
through the skin, see personal protection equipment.

VENTILATION

A local exhaust ventilation system as supplied with the machines, should be
installed so that vapours are safely vented to atmosphere away from windows
and other air inlets. In accordance with the Control of Substances Hazardous to
Health regulations 1988 the system should be maintained and undergo a
thorough examination.

PERSONAL

Suitable gloves must be worn when replacing and removing spray guns from the

PROTECTION

cleaning machine. Most glove manufacturers recommend Nitrile gloves for the

EQUIPMENT

solvent xylene and toluene, which can be absorbed through the skin.

WASTE DISPOSAL

Waste solvent must be removed by a registered carrier to a disposal or recovery
facility licensed to receive waste solvent.

EMERGENCY

FIRE

ACTION

In case of fire, use a form of dry powder extinguishing agent. Cool solvent drums
exposed to fire with water spray.

FIRST AID
Eye contact with solvent- irrigate with clean water. Skin contact with solvent-
remove contaminated clothing, wash skin thoroughly with soap and water.

Excess inhalation of solvent vapours – Remove to fresh air, seek medical
attention

Accidental Ingestion – Do not induce vomiting, seek medical attention.

SPILLAGE OF SOLVENT
Contain and collect with non-combustible materials E.g. sand and earth. Do not
allow to enter drains. Exclude sources of ignition. Ventilate area.

SUPPLIER

Unic International (UK)

INFORMATION

Colwick Road, Nottingham NG2 4BG
Tel +44 (0) 115 947 4000
Fax +44 (0) 115 950 6666

Содержание UGC2005

Страница 1: ...hould come with Also available Installation fittings We also recommend I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Solvent Based Spray Gun Cleaner Operating Instructions UGC2005 UGC2005M UGC3005 UGC4005 UGC5005 786 Air Dirt Water trap 783 Nipple FRA3 3 Angle Flange FR3 3 Angle Flange Flat F6R5 6 to 5 Reducer FF3 3 Flange Flat F5R3 5 to 3 Reducer FD3 3 Flexi Ducting Gate V...

Страница 2: ...ted area The extraction outlet will accept 3 75mm hose and should be connected to an existing system or taken to the external part of a building and vented via the atmosphere Hose and a range of adaptors are available direct from Unic International The machine will take 20 25 or 30 litre solvent containers When installing 25 30 litre containers we advise that you raise the adjustable corner legs C...

Страница 3: ...6mm nylon tube with wire clip in to the full 5 litre container Repeat this step for UGC5005 Turn drain valve lever to vertical position see diagram 2 Underneath the machine at the rear are the earthing wire s the crocodile clip s must be attached to any metal solvent container s if used these are not supplied by Unic international 1 2 3 4 5 6 7 MAINTENANCE CHECK Grid Filter It is recommended that ...

Страница 4: ...ion 1 Close lid UGC4005 and UGC5005 ONLY Ensure mode valve control lever is in the automatic position horizontal Turn timer knob clockwise The machine will run automatically for approximately 4 minutes Upon completion open the lid and remove the spray guns from the machine We advise that you DO NOT store the spray guns in the machine MANUAL WASH CLEAN RINSE UGC4005 UGC5005 and UGC2005M For UGC2005...

Страница 5: ...he lid was open for removal of the spray gun cups and hoses and just 6 of the limit during the cleaning cycle Substances in the solvent however can be absorbed through the skin see personal protection equipment VENTILATION A local exhaust ventilation system as supplied with the machines should be installed so that vapours are safely vented to atmosphere away from windows and other air inlets In ac...

Страница 6: ...0ppm 10 min TWA detection Propan 2 OL 500 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Propyl Acetate 250 ppm Less than limit of Less than limit of Not measured 10 min TWA detection detection Butyl Acetate 200 ppm Less than limit of 30ppm 10ppm 10 min TWA detection Xylene 150 ppm Less than limit of 20ppm 150ppm 10 min TWA detection Toluene 150 ppm 3ppm 10pp...

Страница 7: ...ized standards Certified to Atex standards Certificate number SIRA 03ATEX5252 EC Notified Body not applicable Approved By Date Director Signed Date Director Printed I N T E R N A T I O N A L T h e p r o f e s s i o n a l s c h o i c e Unic International Colwick Road Nottingham NG2 4BG England Tel 44 0 115 947 4000 Fax 44 0 115 950 6666 Email info unic co uk Web www unic co uk Declaration of Confor...

Страница 8: ...CFM 28 56 L min Air Input Connection 1 4 B S P Year of manufacturing 2013 14 Height 1020mm Width 555mm Depth 350mm Weight 31kg Directive 94 9 EC Marking Ex II 2G T6 Certificate Number SIRA 03ATEX5252 Model UGC4005 Air Input 40 90 PSI 2 75 6 Bar Air Consumption 1 2 CFM 28 56 L min Air Input Connection 1 4 B S P Year of manufacturing 2013 14 Height 1020mm Width 710mm Depth 350mm Weight 47kg Directiv...

Страница 9: ... A L T h e p r o f e s s i o n a l s c h o i c e Information Request Form FAX BACK 44 0 115 950 6666 Please send information on please tick appropriate box Mini Spray Gun Cleaners Can Crushers Paint Can Washers Paint Can Shakers Brake Washer Parts Washer Solvent Recycler Spares Service Information Other Comments Please send this information to Name Address Email Telephone Fax ...

Страница 10: ...ctions as to the storage installation commissioning use or maintenance of the Machine or if there are none good trade practice or d the Buyer alters or repairs the Machine other than by replacing consumable items such as filters jets and flow through brush or such units as are intended to be replaced by the user as specified in the manual without the written consent of the Company or f any parts n...

Отзывы: