background image

10

isolation fault in the TN or TT systems or, for IT systems, the use of isolation controllers
or differential current protection devices to activate automatic power disconnection (an
isolation controller must be provided for indicating a possible first earth fault of a live part,
unless a protection device is supplied for switching off the power in case of a such a fault.
This device must activate an acoustic and/or visual signal which must continue for the
entire duration of the fault). For example: in a TT system, a residual current device with
cut-in current (e.g. 30 mA) coordinated with the earthing system of the building where
the appliance is located must be installed ahead of the supply.

A.8

Use

• The appliance must be used in room with an ambient temperature of 5

to 35

(41

-

95

).

• If it is stored at an ambient temperature below 5

(41

) the water circuit (boiler-piping)

must be drained.

• In case of emergency (fire, surge, abnormal noise, etc. the first thing to do is to cut off the

current and close the water tap.

• Make sure not to obstruct the air inlets of the appliance with towels or other objects.
• Beware of hot surfaces such as cup heaters, the unit heads and the hot water and steam

outputs. Never install containers filled with liquid on the top of the appliance.

A.9

appliance cleaning and maintenance

• Refer to “A.3

Personal protection equipment

“ for suitable personal protection equipment.

• Put the appliance in safe conditions before starting any maintenance operation.

Disconnect the appliance from the power supply and carefully unplug the power supply
cable, if present.

• Depending on the model and type of electric connection, during maintenance operations,

the cable and plug must be kept in a visible position by the operator carrying out the work.

• Do not touch the appliance with wet hands or feet or when barefoot.
• Do not remove the safety guards.
• Respect the requirements for the various routine and extraordinary maintenance

operations. Non compliance with the instructions can create risks for personnel.

• Extraordinary maintenance, checking and overhaul operations must only be carried out

by a specialised personnel or the Customer Care Service, provided with suitable
personal protection equipment (safety shoes and gloves), tools and ancillary means.

• Do not clean the appliance with jets of water.

Repair and extraordinary maintenance

• Repair and extraordinary maintenance have to be carried out by specialised authorised

personnel. The manufacturer declines any liability for any failure or damage caused by
the intervention of an unauthorized technician by the Manufacturer and the original
manufacturer warranty will be invalidated.

• The appliance should be descaled only by a specialised personnel.
• Do not forget to regenerate your water softener periodically.

A.10

Service

• Only original spare parts can ensure the safety standards of the appliance.

A.11

Disposal of packing

• Dispose of each packaging items respecting the current regulation in the country of

installation.

Содержание STELLA EPIC 3

Страница 1: ...STELLA EPIC EN User manual Original instructions SE9020 2021 01...

Страница 2: ...2 Installation diagram EPIC 2 790 730 5 3 mini 790 310 350 410 395 270 300 50 mini 50mini AVANT FRONT EI DO CWI x a m 5 9 1 515 0 0 7 682 50 mini 699 3 1 5 3 0 1...

Страница 3: ...3 Installation diagram EPIC 3 x a m 5 9 1 515 0 0 7 682 50 mini 699 3 1 5 3 0 1 980 920 53 mini 980 310 350 410 300 470 270 50 mini 50 mini AVANT FRONT EI CWI DO...

Страница 4: ...4 DO Drain outlet EI Electricity inlet CWI Cold water inlet G 3 8...

Страница 5: ...ine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding machine use do not hesitate to contact th...

Страница 6: ...opyright 13 C 7 Keeping the manual 13 C 8 Recipients of the manual 13 D NORMAL USE 14 D 1 Characteristics of personnel enabled to operate on the machine 14 D 2 Characteristics of personnel trained for...

Страница 7: ...hine Keep all packaging and detergents away from children Cleaning and user maintenance shall not be made by children without supervision For suitable personal protection equipment refer to chapter A...

Страница 8: ...required PPE Failure to use the personal protection equipment by operators specialized personnel or users can involve exposure to chemical risk and cause possible damage to health depending on the mod...

Страница 9: ...me where repair work has been carried out or new devices fitted water meters etc let the water flow until it is clean and clear The dynamic water pressure minimum and maximum must be between 1 bar 0 1...

Страница 10: ...ent Put the appliance in safe conditions before starting any maintenance operation Disconnect the appliance from the power supply and carefully unplug the power supply cable if present Depending on th...

Страница 11: ...ing do not oil lubricate repair and adjust moving parts do not remove the safety devices do not use water to extinguish fires placed on electrical parts Danger Meaning caution hot surface danger of el...

Страница 12: ...ns carried out with the electrical panel powered Crushing or injury The specialised personnel may not correctly fix the control panel when accessing the technical compartment The panel could close sud...

Страница 13: ...operation and invalidates the original manufacturer warranty operations carried out by non specialised personnel unauthorized modifications or operations missing lack or inadequate maintenance imprope...

Страница 14: ...ck motor breakdowns worn electrical cable sheathing etc the operator for normal machine use must E TECHNICAL CHARACTERISTICS E 1 Data table ELECTRIC SUPPLY POWER Watt I single phase A I three phases n...

Страница 15: ...e containing a summary of the information relating to the whole of the machine in real time Direct controls for a Level 0 user 2 Cleaning icon to access all available operations of cleaning and flushi...

Страница 16: ...G 1 Cleaning groups G 1 1 Before use or after several hours of inactivity Drain for each unit and water outlet 0 5 liter of water for each steam outlet steam for 1 minute IMPORTANT Before preparing a...

Страница 17: ...hol for the stainless steel parts and a nonabrasive cleaning agent for the painted parts Simply take care not to scratch the painted parts Keyboards cleaning IMPORTANT Never clean keyboard with liquid...

Страница 18: ...only I 3 Use I 3 1 Automatic mode To reach the programmed T One impulse on the touch makes the Steamair flow until the liquid reaches the preset temperature You can stop it manually by pushing again...

Страница 19: ......

Страница 20: ...Z I 4e RUE BP 425 06515 CARROS CEDEX 1 FRANCE Tel 33 04 92 08 62 60 Fax 33 04 93 29 24 23 www unic sa com...

Отзывы: