background image

9

A.5

Installation and assembly

• The installation must be carried out by a specialised personnel.
• Follow the installation instruction supplied with the appliance.
• Do not install a damaged appliance. Any missing or faulty parts must be replaced with

original parts.

• Do not make any modifications to the parts supplied with the appliance.
• Disconnect the appliance from the power supply before carrying out any installation

procedure. Connect the appliance to the power supply only at the end of the installation.

• The appliance is not suitable for installation outdoors and/or in places exposed to

atmospheric agents (rain, direct sunlight, freeze, humid and dusty location, etc.).

• Make sure that the floor where you install the appliance is flat, stable, heat resistant and

clean.

• Access to the service area is limited to persons with the necessary knowledge of safety

and hygiene as well as practical experience of the device.

• Leave enough free space around the appliance to facilitate its use and to preform any

maintenance operations.

A.6

Water connection

• The plumbing connections must be carried out by a specialised personnel.
• The machine is to be connected to the water mains using the new supplied hose-sets.

Do not use old hose sets.

• Always use a new set of joints if you remove and re-install the water inlet pipe to the

machine.

Before connection to new pipes, pipes not used for a long time, where repair work has

been carried out or new devices fitted (water meters, etc.), let the water flow until it is
clean and clear.

• The operating water pressure (minimum and maximum) must be between:

– 1 bar [0.1 MPa] and 8 bar [0.8 MPa];

• Make sure that there are no visible water leaks during and after the first use of the

machine.

• Install an approved dual check valve upstream according to the regulation of the

installation country.

A.7

Electrical connection

• Work on the electrical systems must only be carried out by a specialised personnel.
• Make sure that the electrical information on the rating plate agrees with the power supply.
• Make sure to install the appliance in accordance with the safety regulations and local

laws of the country where used.

• If the power cable is damaged it must be replaced by the Customer Care Service or in

any case by specialised personnel, in order to prevent any risk.

• The appliance must be correctly earthed. The manufacturer is not responsible for the

consequences of an inadequate earthing system.

• To protect the power supply of the appliance against short circuits and/or overloads,

install a thermal fuse or a suitable automatic thermal magnetic circuit breaker, ADS
(Automatic Disconnection of Supply).

• To protect the power supply of the appliance against current leakages, install a high-

sensitivity manual reset RCD (Residual Current Device), suitable for overvoltage
category III.
For protection against indirect contacts, refer to point 6.3.3 of EN 60204-1 (IEC 60204-1)
with the use of protection devices that ensure automatic cut-off of the supply in case of

Содержание AURA 2

Страница 1: ...AURA EN User manual Original instructions AU9920 2020 06 ...

Страница 2: ...2 Installation diagram AURA 2 594 311 90 265 374 360 794 700 481 50 min DO EI EQ CW I 666 488 50 890 min 794 81 592 374 ...

Страница 3: ...3 installation diagram AURA 3 594 984 1080 min 265 984 340 50min DO EI CW I EQ 856 678 700 481 50 min 592 374 ...

Страница 4: ...4 DO Drain outlet EI Electricity inlet EQ Equipotential screw CWI Cold water inlet G 3 8 ...

Страница 5: ...hine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding machine use do not hesitate to contact the Manufacturer or the au thorised Service Centre to receive prompt and precise assistance for better operation and maximum efficiency of the machine During all stages of machine use always respect th...

Страница 6: ...Copyright 14 D 7 Keeping the manual 14 D 8 Recipients of the manual 14 E NORMAL USE 14 E 1 Characteristics of personnel enabled to operate on the machine 14 E 2 Characteristics of personnel trained for normal machine use 14 E 3 Operator qualified for normal machine use 14 F TECHNICAL CHARACTERISTICS 15 F 1 Data table 15 G OPERATING 15 G 1 Switching on 15 G 2 Keyboards 15 G 2 1 4 doses box 15 G 2 2...

Страница 7: ...chine Keep all packaging and detergents away from children Cleaning and user maintenance shall not be made by children without supervision For suitable personal protection equipment refer to chapter A 3 Personal protection equipment Several illustrations in the manual show the machine or parts of it without guards or with guards removed This is purely for explanatory purposes Do not install the ma...

Страница 8: ... required PPE Failure to use the personal protection equipment by operators specialized personnel or users can involve exposure to chemical risk and cause possible damage to health depending on the model A 4 Transport handling and storage Due to their size the machines cannot be stacked on top of each other during transport handling and storage this eliminates any risks of loads tipping over due t...

Страница 9: ...me where repair work has been carried out or new devices fitted water meters etc let the water flow until it is clean and clear The operating water pressure minimum and maximum must be between 1 bar 0 1 MPa and 8 bar 0 8 MPa Make sure that there are no visible water leaks during and after the first use of the machine Install an approved dual check valve upstream according to the regulation of the ...

Страница 10: ...ment Put the appliance in safe conditions before starting any maintenance operation Disconnect the appliance from the power supply and carefully unplug the power supply cable if present Depending on the model and type of electric connection during maintenance operations the cable and plug must be kept in a visible position by the operator carrying out the work Do not touch the appliance with wet h...

Страница 11: ...r consumable cleaning products that are not approved by the manufacturer customer s negligence misuse abuse and or non com pliance with the use and care instructions detailed within the appropriate equipment documentation improper or poor installation repair maintenance including tampering modifications and repairs carried out by third parties not authorized and modification of safety systems Use ...

Страница 12: ...intenance personnel failure to use suitable accessories e g use of unsuitable equipment or ladders keeping combustible or flammable materials or in any case materials not compatible with or pertinent to the work near the machine wrong machine installation placing in the machine any objects or things not compatible with its use or that can damage the machine cause injury or pollute the environment ...

Страница 13: ...rations to be carried out on the machine and recognise and prevent any risks His professionalism covers the mechanical electrotechnical and elec tronics fields etc Danger source of possible injury or harm to health Hazardous situation any situation where an operator is exposed to one or more hazards Risk a combination of probabilities and risks of injury or harm to health in a hazardous situation ...

Страница 14: ...er receives from the Manufacturer will form an integral part of the manual and therefore must be kept together with it D 6 Copyright This manual is intended solely for consultation by the operator and can only be given to third parties with the permission of ELECTROLUX D 7 Keeping the manual The manual must be carefully kept for the entire life of the machine until scrapping The manual must stay w...

Страница 15: ...E When the machine has been installed and the hydraulic electrical connections have been carried out by a qualified installer WARNING Do not forget to open the water tap supplying the machine G 1 Switching on Fig 1 Main switch 1 Heating 2 power turn ON and filling boiler s 3 appliance OFF Turn ON the appliance Put the main On Off switch on position 1 do not put it on position 2 until the boiler is...

Страница 16: ...s a 3rd dose by default the continuous cycle has a security stop at 180 s Procedure Press desired touch to lunch a coffee cycle When the dose is reached press the same touch again to stop the cycle and memorize the dose Repeat the same procedure for the other touchs Validate the settings stay pressed 3 seconds on the cleaning icon NOTE For the dosamat case the box detects the number of cups when i...

Страница 17: ...ce of dust damp etc therefore precise time intervals cannot be given In any case careful and periodical machine maintenance is advisable in order to minimise service interruptions I 1 1 Preventive Maintenance Preventive Maintenance reduces downtime and maximizes machines efficiency Customer Care Service can provide advice on the best maintenance plan to be purchased based on the intensity of use a...

Страница 18: ...r icon small dose 2 Display 3 Steam icon 4 Steamair icon 5 Continu stop icon 6 Hot water icon large dose J 4 1 Small hot water delay time adjustment Press on the icon let the desired time flow the time in seconds is indicated on the display Press again on the same icon to stop the cycle J 4 2 Large hot water delay time adjustment Press on the icon let the desired time flow the time in seconds is i...

Страница 19: ......

Страница 20: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...

Отзывы: