background image

Unibor E100 Manual 

                   Original instructions 

               Apr 2020 

 

 

 

1) INTENDED USE 

 
The intended use of this magnetic drill is to drill holes in ferrous metals. The magnet is used to hold the drill in 
place whilst the drill is functioning. It is designed for use in fabrication, construction, railways, petrochemical 
and any other applications when drilling ferrous metal.  
Any deviation from its intended use will not be covered by warranty. 

 

 

2) GENERAL SAFETY RULES

 

 

 

WARNING!

 Read and understand all instructions. Failure to follow all instructions listed below, may result 

in electric shock, fire and/or serious personal injury. 

 

SAVE THESE INSTRUCTIONS. 
 
Work area 

1.

Keep your work area clean and well lit

. Cluttered benches and dark areas invite accidents. 

2.

Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases 

or dust.

 Power tools create sparks which may ignite the dust or fumes. 

3.

Keep bystanders, children and visitors away while operating a power tool. 

Distractions can cause you to 

lose control 
 

Electrical safety  

1.

Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all 

codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any 
adaptor plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly 
grounded. 

If the tools should electrically malfunction or break down, grounding provides a low resistance path 

to carry electricity away from the user. 

2.

Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. 

There is an 

increased risk of electric shock if your body is grounded. 
3.

Do not expose power tools to rain or wet conditions. 

Water entering a power tool will increase the risk of 

electric shock.  
4. 

Do not abuse the cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord 

away from heat, oil, sharp edges or moving parts. Replace damaged cords immediately. 

Damaged cords 

increase the risk of electric shock.  
5. 

When operating a power tool outside, use an outdoor extension cord 

marked” W

-A

” 

or

” W”

These cords 

are rated for outdoor use and reduce the risk of electric shock.  
 

Personal safety  

1. 

Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use 

tool while tired or under the influence of drugs, alcohol, or medication. 

A moment of inattention while 

operating power tools may result in serious personal injury.  
2. 

Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and 

gloves away from moving parts. 

Loose clothes, jewelry, or long hair can be caught in moving parts.  

3. 

Avoid accidental starting. Be sure switch is off before plugging in. 

Carrying tools with your finger on the 

switch or plugging in tools that have the switch on invites accidents.  
4. 

Remove adjusting keys or switches before turning the tool on. 

A wrench or a key that is left attached to a 

rotating part of the tool may result in personal injury.  
5. 

Do not overreach. Keep proper footing and balance at all times. 

Proper footing and balance enable better 

control of the tool in unexpected situations.  
6. 

Use safety equipment. Always wear eye protection. 

Dust mask, non-skid safety shoes, hardhat, or hearing 

protection must be used for appropriate conditions.  

 
 

Содержание E100

Страница 1: ...Unibor E100 Manual Original instructions Apr 2020 1 Magnetic drilling machine Model Number E100 Serial Number Website www unibor com ...

Страница 2: ...l safety procedures Operating instructions Extension cable selection Mounting of cutters Remedies for hole making problems Wiring diagram Exploded view Motor Breakdown Control panel and parts List Maintenance Trouble shooting Cutter selection Warranty 3 3 4 5 6 6 7 7 8 9 10 13 14 15 16 17 18 Part Description Quantity KEY01 Allen key 2 5mm 1 KEY04 Allen key 5mm 1 VISO10 Guard 1 STRAP01 Safety Strap...

Страница 3: ...pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock 4 Do not abuse the cord Never use the cord to carry the tools or pull the plug from an outlet Keep cord away from heat oil sharp edges or moving parts Replace damaged...

Страница 4: ...bind and are easier to control 7 Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the tools operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools 8 Use only accessories that are recommended by the manufacturer or your model Accessories that may be suitable for one tool may become haza...

Страница 5: ...h 11 1 32 Length Overall 13 3 16 Nett Weight 59 5 lbs Vibration total values triax vector sum in accordance with EN50144 Vibration emission value a W 2 47 m s Uncertainty K 1 5m s Level of sound pressure in accordance with EN50144 LpA 86 dB A uncertainty K 3dB A Ear and eye defenders must be worn when operating this machine Wear gloves to protect hands when operating the machine These tools are UK...

Страница 6: ... from the arbor If the machine is accidentally dropped ALWAYS thoroughly examine the machine for signs of damage and check that it functions correctly BEFORE resuming drilling Regularly inspect the machine and check for any damaged or loose parts ALWAYS ensure when using the machine in an inverted position that only the minimum amount of coolant is used and that care is taken to ensure that coolan...

Страница 7: ...ety hazard Assuming a normal AC supply of the correct voltage it is recommended that the following extension lengths shall not be exceeded For 120v supply 11 feet of 3 core x 16AWG ALWAYS DISCONNECT THE MACHINE FROM THE POWER SOURCE BEFORE CHANGING CUTTERS 8 MOUNTING OF CUTTERS The machine has been made to accept cutters having dia Weldon shanks The following procedure is to be used when mounting ...

Страница 8: ...prove centre punch and or replace worn parts Replace part or parts 3 Excessive drilling pressure required Incorrectly re sharpened worn or chipped cutter Coming down on swarf lying on surface of workpiece Swarf accumulated packed inside cutter Re sharpen or replace Take care not to start a cut on swarf Clear cutter 4 Excessive cutter breakage Steel swarf or dirt under cutter Incorrectly re sharpen...

Страница 9: ...Unibor E100 Manual Original instructions Apr 2020 9 10 WIRING DIAGRAM Standard Wiring Diagram MLC Wiring Diagram ...

Страница 10: ...Unibor E100 Manual Original instructions Apr 2020 10 11 EXPLODED VIEW OF MACHINE ...

Страница 11: ...0076 OIL CUP RET CLIP 83250 BP PLASTIC COATED CLIP 1 16 30046 1 LARGE PLASTIC OIL CUP COMPLETE WITH TAP 1 17 40026 M16 PUSH FIT GLAND PMA BVND M160GT 1 18 50015C 1 8 BSP 6MM MSC PCO6 01 6MM BLACK PUSH FIT 1 19 10085A M5X25 KNURLED POINT GRUB SCREW 6 20 BD029 U 06040 30MC 6MM X 4MM CLEAR POLYURETHANE TUBE 1 21 10085B M5 NYLOC 6 22 M0071 PINION END CAP 1 23 M0081 BUSH PINION 33 X 28 X 20 OILITE BUSH...

Страница 12: ...Unibor E100 Manual Original instructions Apr 2020 12 12 MOTOR BREAKDOWN ...

Страница 13: ...8 EIB156 SUPRESSOR 1 19 EIB157 SCREW HC4 8 X 50 4 20 EIB045B SPEED CONTROL KNOB 1 21 EIB158 SCREW HC 4 8 X 45 2 22 EIB159 LOCATING DOWEL 1 23 EIB082 GEAR PLATE SHEILD 1 25 EIB160 SCREW 6 X 20 4 26 EIB161 WASHER A6 4 27 EIB032 GEAR PLATE 1 28 EIB043 CIRCLIP 1 29 UDC012 BEARING 6201 1 30 EIB143 CIRCLIP 1 31 UDC020 BEARING HK0810 3 33 EIB031 GEARBOX HOUSING 1 34 UDC001 BEARING 6000 2 35 UDC021 BEARIN...

Страница 14: ...SHER 28X 12 2 52 EIB148 WASHER 12 18 X 0 05 1 53 EIB150 THRUST WASHER 1 54 EIB149 CLUTCH COUPLING 1 55 EIB144 THUST WASHER 12 1 X 18 1 56 EIB012 GEAR SHAFT 1 57 EIB034 KEY 5 X 5 X 28 1 58 EIB009 DOUBLE GEAR 1 59 EIB013 GEAR SHAFT 1 60 EIB010 SPUR GEAR 1 61 EIB195 GEAR LEVER 1 62 EIB017 GEAR LEVER ASSEMBLY 1 63 EIB201 CLUTCH GEAR ASSEMBLY 1 ...

Страница 15: ...iginal instructions Apr 2020 15 13 CONTROL PANEL AND PARTS LIST No Part Number Description Quantity 1 NCP035 Control Panel Plate 1 2 NCP001 Motor Stop Start Switch 120V 1 3 NCP006 Magnet Switch 1 4 M0401 Bridge Rectifier 1 ...

Страница 16: ...must be checked to ensure that all components are working correctly Machine Brushes should be checked to make sure there is no abnormal wear present this should be checked at least once a week if used frequently If the brush has worn more than 2 3 the original length the brushes should be changed Failure to do so may cause damage to the machine Magnetic base before every operation the magnetic bas...

Страница 17: ... sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged Field burned Carbon brushes worn out Motor does not start or fails Damaged or defective wiring Damage to armature or field coil Damaged or defective brushes Insufficient magnetic force Damaged or defective wiring Bottom of magnet not clean and dry ...

Страница 18: ... Steel angle and joists 700N mm M2 Steel angle and joists 850N mm M42 Plate and sheet steel 700N mm M2 Plate and sheet steel 850N mm M42 Aluminium 750Nmm M2 Aluminium 850N mm M42 Brass 700N mm M2 Brass 850N mm M42 Cast iron 700N mm M2 Cast iron 850N mm M42 Stainless steel 700N mm M2 Stainless steel 850N mm M42 Stainless steel 850N mm TCT Rail track 850N mm M42 Tool steel 850N mm TCT Die Steel 850N...

Страница 19: ...nditions inappropriate operating conditions overload or insufficient servicing or maintenance 3 Defects caused by using accessories components or spare parts other than original Unibor parts 4 Tools to which changes or additions have been made 5 Electrical components are subject to manufacturer s warranty The warranty claim must be logged within the warranty period This requires the submission or ...

Отзывы: