Maintenance
19
Fig 9
Fig 10
8. Standard Divider Seal
Using a suitable tool, push the divider seal up into
the groove until the bottom can be pulled or pushed
out and removed.
The groove in the body is machined so that it
is deeper towards the top of the pump.
Fig 11
9. Snap Fit Divider Seal
The divider seal may be pushed out with a suitable
blunt tool whilst taking care not to damage the face
of the body.
Fig 12
10. Unscrew the two bolts and remove the delivery
manifold.
11. Remove the two delivery balls.
www.unibloctech.co