2-3   OPERATION CONCEPT 

 

 

Voltage Variation   

        The output voltage was designed to be linear adjusted variably using volume with power TR 

PAM control type among 0 ~ 300V according to the status of voltage range.   

 

 

Frequency Invert   

        The  output  frequency  was  designed  for  input  60Hz  to  be  inverted  using  PAM  control  type 

and 40 ~ 999Hz frequency is output.   

 

 

SECTION 3 

                                          OPERATION

   

                                     

3-1 PREPARATIONS BEFORE USE 

 

 

The hear generated by AC Power Source is released thru rear panel so please place the 

machine minimum 10cm away from other equipment or wall so that the air flow goes on 

smoothly. 

 

Do not place any articles in the base and side of the machine so that the air flow goes on 

smoothly without closing air ventilation holes.   

 

Do not place the machine to be exposed direct to the sun or eroded gas. 

 

Do not place the machine in the room with vibration or lots of dust. 

 

Do  not  operate  the  machine  if  there  is  some  damage  with  fuse  holder,  panel  meter, 

switches and other mechanical parts.   

   

3-2 ELECTRICAL CHECK 

 

1. Turn both Electric Source Switch and Power Switch OFF. 

2. Place all Voltage Adjust VR at the minimum range. 

3. Adjust Frequency Preset Volume to the range to be desired. 

4. Check  whether  the  input  power  voltage  to  be  used  is  the  same  as  single  phase  AC 

220V/60Hz.   

5. Connect AC input terminal of the machine with power source. 

6. Turn the Power Switch ON and check if the frequency counter is displayed. 

Содержание ACP Series

Страница 1: ...ATION MANUAL AC POWER SOURCE PAM Power Amplitude Modulation Type ACP SERIES ACP 200 200VA ACP 500 500VA ACP 1K 1 000VA ACP 2K 2 000VA ACP 3K 3 000VA ACP 5K 5 000VA ACP 10K 10 000VA UNISOURCE CORPORATI...

Страница 2: ...ND FUNCTION 2 1 PHYSICAL STRUCTURE 2 2 EACH DEVICE S FUNCTION 2 3 OPERATION CONCEPT SECTION 3 OPERATION 3 1 PREPARATIONS BEFORE USE 3 2 ELECTRICAL CHECK 3 3 CAUTION FOR USERS 3 4 FRONT PANEL LAYOUT 3...

Страница 3: ...sed very frequently is set with Frequency Selector Switch Any frequency from 40 to 999Hz is to be selected using Push Wheel Digital Switch The cooling system for this model is a compulsory air cooling...

Страница 4: ...e 0 300V Option 0 500V 1Phase or 3Phase Load Regulator Less than 0 5 Current Limit L 1 3A H 0 66A L 3 33A H 1 66A L 6 67A H 3 33A L 13 3A H 6 67A L 20A H 10A L 33 3A H 16 6A L 66 6A H 33 3A Output Wav...

Страница 5: ...vice converts alternating electric current AC into direct current DC and provides it to the Inverter section The direct current DC converted by rectifier circuit may include some ripple voltage The ri...

Страница 6: ...rror and makes control circuit be controlled in safety free from overload voltage and noise input outside the device Digital Display Panel This device consists of display and operation switch and digi...

Страница 7: ...les in the base and side of the machine so that the air flow goes on smoothly without closing air ventilation holes Do not place the machine to be exposed direct to the sun or eroded gas Do not place...

Страница 8: ...this Technical and Operation Manual thoroughly and operate the machine according to the procedures in the manual The input power should be single phase AC 220V 60Hz The GROUND of the power line should...

Страница 9: ...Switch should be at LOW up to 150V then the position should be at HI up to 300 over 150V The dual transformer is being used with this system since the frequency bandwidth is wide It should be at DOWN...

Страница 10: ...LED displays the desired frequency then turn the Output Switch ON And then check if Output LED is lit If Output LED is lit please turn the Voltage Adjust MINE VR in clockwise by looking at Output Volt...

Страница 11: ...on Resistance and Insulation Internal Pressure PCB and control circuit Semi conductor elements Filter and surge elements Condenser elements Temperature Rise Transformer and reactor elements less than...

Страница 12: ...r Power TR PAM control type Input Rated voltage single phase 220V Voltage variation tolerance field 10 Frequency 60Hz Frequency variation tolerance field 5 Output Rated voltage single phase 0 300V Vol...

Страница 13: ...SECTION 5 SERVICE 5 1 SCHEMATIC DIAGRAM...

Страница 14: ...2 The Overload LED is lit when Power Switch is ON Power transistor is out 5W 0 1 resistor connected with power transistor emitter is out Replace power transistor Replace 5W 0 1 resistor 3 The system i...

Отзывы: