![UNI ACP Series Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/uni/acp-series/acp-series_technical-and-operational-manual_3658627014.webp)
5-2 SYMPTOMS AND REPAIR
SYMPTOMS
REPAIR
1. The system does not turn ON when Power Switch is
ON
★
Fuse is out in Input side
★
Power transformer is out
★
Replace the fuse
★
Replace Power Transformer
2. The Overload LED is lit when Power Switch is ON
★
Power transistor is out
★
5W/0.1
Ω
resistor connected with power transistor
emitter is out
★
Replace power transistor
★
Replace 5W/0.1
Ω
resistor
3. The system is normal but the output does not come
out when Power Switch is ON
★
The SCR of rectifier is out
★
Replace the SCR of rectifier
☞
Please contact the factory or local distributor for other repairs..