5-2 SYMPTOMS AND REPAIR

 

         

SYMPTOMS 

REPAIR 

1. The system does not turn ON when Power Switch is 

ON 

  Fuse is out in Input side 

  Power transformer is out   

 

 

  Replace the fuse 

  Replace Power Transformer 

2. The Overload LED is lit when Power Switch is ON   

  Power transistor is out 

  5W/0.1

  resistor connected with power transistor 

emitter is out 

 

  Replace power transistor 

  Replace 5W/0.1

  resistor 

3. The system is normal but the output does not come 

out when Power Switch is ON   

  The SCR of rectifier is out   

 

 

  Replace the SCR of rectifier 

 

  Please contact the factory or local distributor for other repairs.. 

 

 

 

Содержание ACP Series

Страница 1: ...ATION MANUAL AC POWER SOURCE PAM Power Amplitude Modulation Type ACP SERIES ACP 200 200VA ACP 500 500VA ACP 1K 1 000VA ACP 2K 2 000VA ACP 3K 3 000VA ACP 5K 5 000VA ACP 10K 10 000VA UNISOURCE CORPORATI...

Страница 2: ...ND FUNCTION 2 1 PHYSICAL STRUCTURE 2 2 EACH DEVICE S FUNCTION 2 3 OPERATION CONCEPT SECTION 3 OPERATION 3 1 PREPARATIONS BEFORE USE 3 2 ELECTRICAL CHECK 3 3 CAUTION FOR USERS 3 4 FRONT PANEL LAYOUT 3...

Страница 3: ...sed very frequently is set with Frequency Selector Switch Any frequency from 40 to 999Hz is to be selected using Push Wheel Digital Switch The cooling system for this model is a compulsory air cooling...

Страница 4: ...e 0 300V Option 0 500V 1Phase or 3Phase Load Regulator Less than 0 5 Current Limit L 1 3A H 0 66A L 3 33A H 1 66A L 6 67A H 3 33A L 13 3A H 6 67A L 20A H 10A L 33 3A H 16 6A L 66 6A H 33 3A Output Wav...

Страница 5: ...vice converts alternating electric current AC into direct current DC and provides it to the Inverter section The direct current DC converted by rectifier circuit may include some ripple voltage The ri...

Страница 6: ...rror and makes control circuit be controlled in safety free from overload voltage and noise input outside the device Digital Display Panel This device consists of display and operation switch and digi...

Страница 7: ...les in the base and side of the machine so that the air flow goes on smoothly without closing air ventilation holes Do not place the machine to be exposed direct to the sun or eroded gas Do not place...

Страница 8: ...this Technical and Operation Manual thoroughly and operate the machine according to the procedures in the manual The input power should be single phase AC 220V 60Hz The GROUND of the power line should...

Страница 9: ...Switch should be at LOW up to 150V then the position should be at HI up to 300 over 150V The dual transformer is being used with this system since the frequency bandwidth is wide It should be at DOWN...

Страница 10: ...LED displays the desired frequency then turn the Output Switch ON And then check if Output LED is lit If Output LED is lit please turn the Voltage Adjust MINE VR in clockwise by looking at Output Volt...

Страница 11: ...on Resistance and Insulation Internal Pressure PCB and control circuit Semi conductor elements Filter and surge elements Condenser elements Temperature Rise Transformer and reactor elements less than...

Страница 12: ...r Power TR PAM control type Input Rated voltage single phase 220V Voltage variation tolerance field 10 Frequency 60Hz Frequency variation tolerance field 5 Output Rated voltage single phase 0 300V Vol...

Страница 13: ...SECTION 5 SERVICE 5 1 SCHEMATIC DIAGRAM...

Страница 14: ...2 The Overload LED is lit when Power Switch is ON Power transistor is out 5W 0 1 resistor connected with power transistor emitter is out Replace power transistor Replace 5W 0 1 resistor 3 The system i...