12
FAULT
POSSIBLE CAUSES
TROUBLE SHOOTING
The fuses are blown when you press
the table rotation pedal
Short circuit of the motor power cable to
ground. Short circuit in the motor
Check the wires
The table rotation pedal does not return
to the center position
Broken pedal spring
Replace the spring
The bead-breaker pedal and table pedal
do not return to initial position
No oil in the grease gun
Fill the lubricator with HL 32
(hydraulic) oil
Broken pedal spring
Replace the spring
Air escapes at the bead-breaker piston
Worn air seal
Replace the gasket
Difficulties with the table when
dismantling and installing tyres
Belt tension insufficient
Adjust belt tension or replace belt
Pressure gauge indicator does not
return to 0
Defective pressure gauge
Replace the pressure gauge
The wheel does not stay on the table
Low air supply pressure
Adjust (check) the pressure of the
supplied air
Jaws are worn
Replace jaws
The table does not turn in either
direction
No electric power
Check electric supply
Damaged motor
Replace the motor
Broken belt
Replace belt
SERVICE NOTES