![UNI-T UT39E Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/uni-t/ut39e/ut39e_operating-manual_838927016.webp)
For testing the capacitor with polarity, connect the red
test lead to anode & black test lead to cathode
When the tested capacitor is shorted or the value is
overloaded, the LCD display
“1”
.
To minimize the measurement error caused by the
distributed capacitor, the connection should be as short
as possible.
It is normal to take a while for zeroing when changing
over the measurement range. This process will not
affect the accuracy of the final readings obtained.
l
l
l
l
Note
I. Measuring Transistor
(see figure 8)
( figure 8)
To measure transistor, connect the Meter as follows:
1. Set the rotary switch to hFE.
2. Insert the NPN or PNP type transistor to be tested
into the transistor jack
3. The measured nearest transistor value shows on the
display
When transistor measeurement has been completed,
remove the transistor from the transistor jack.
l
Note
16
Model UT39E: OPERATING MANUAL