background image

10

UT361/UT362 OPERATING MANUAL

Number

10

11

12

13

14

15

16

17

18

Meaning

Secondary Data Display

Primary Data Display

Wind Speed Unit - Foot Per Minute

Wind Speed Unit - Meter Per Second

Fahrenheit Temperature Signal / Centigrade Temperature Signal

Cubic Feet Per Second

Cubic Meter Per Minute

Knots Per Hour

Miles Per Hour

Sign

ft/min

m/s

/

CFM

CMM

KNOTS

MPH

Содержание UT361

Страница 1: ...rview Unpacking Inspection Rules For Safety Operation The Anemoscope Structure Display Symbols Setting Up The Anemoscopes Using The Anemoscopes Measuring Wind Speed Computer Connectivity For UT362 only Maintenance Technical Specification 2 3 4 7 8 14 16 21 23 24 27 ...

Страница 2: ...including m s km h ft min MPH KNOT CFM CMM as measuring units In addition it can provide maximum value minimum value average value record Centigrade temperature and Fahrenheit temperature For data storage record the maximum is 2 044 records capability In sync it can provide auto switch down and continuity use functions Model UT362 can work with the computer to conduct the real time wind speed data...

Страница 3: ...362 only 9 V Battery Software Qty 1 piece 1 piece 1 piece 1 piece Warning To avoid electric shock or personal injury read the Rules for Safe Operation carefully before using the Anemoscope Unpacking Inspection Open the package case and take out the Meter Check the following items carefully to see any missing or damaged part ...

Страница 4: ... the user or may damage the anemoscopes or the equipment under test A Note identifies the information that user should pay attention to Rules For Safety Operation Warning Before using the anemoscopes inspect the case do not use the anemoscopes if it is damaged or the case or part of the case is removed Look for cracks or missing plastic Pay attentions to the insulation around the connections ...

Страница 5: ...ttery indicator appears If anemoscopes is in abnormal function stage please stop to use it and sent it your nearby service center for the further investigation Before using the anemoscopes inspects the case do not use the anemoscopes if it is damaged or the case or part of the case is removed Look for cracks or missing plastic Pay attentions to the insulation around the connections Do not use the ...

Страница 6: ...and pole when battery insert Followings are the condition which cause anemoscopes damages Please carefully use it to avoid any unit damage Select the appropriate wind speed before use it may avoid to load wind speed 0 30 m s under the unknown scenarios Select the temperature meaning in 0 to 40 in order to avoid any fan damage caused by the high temperature Do not try to recharge the battery ...

Страница 7: ...UT361 UT362 OPERATING MANUAL The Anemoscope Structure see figure 1 Fan Wind Speed Indicator Handle Secondary Display Primary Display Power Button Operational Button Main Unit 1 2 3 4 5 7 6 8 Figure 1 7 ...

Страница 8: ...8 UT361 UT362 OPERATING MANUAL Display Symbols see figure 2 Figure 2 ...

Страница 9: ...al sign operations Number 1 2 3 4 5 6 7 8 9 Sign MAX MIN AVE READ REC NO USB VEL Meaning Display of Maximum Reading Display of Minimum Reading Data Hold is on Display of Average Reading Display of Data Storage Measurement Reading Display of Data Storage USB is on Wind Speed Measurement The battery is Low ...

Страница 10: ...econdary Data Display Primary Data Display Wind Speed Unit Foot Per Minute Wind Speed Unit Meter Per Second Fahrenheit Temperature Signal Centigrade Temperature Signal Cubic Feet Per Second Cubic Meter Per Minute Knots Per Hour Miles Per Hour Sign ft min m s CFM CMM KNOTS MPH ...

Страница 11: ...iption Power on Power off Button Button 1 This button function key switch is for wind speed measurement and wind count measurement During wind speed measurement press UNIT button m s ft min KNOTS Km h MPH and vice versa During wind count measurement press UNIT button CMM CFM and vice versa ...

Страница 12: ...lue and instant measurement units exchange It can add together in the setup stage Button 3 Press once to enter the Hold mode Press it again to exit Hold mode Continually press to open backlight display Button 4 Press this button to read 100 pieces of data records and function switch on between wind speed measurement mode and wind count measurement mode Button 6 This button function key switch is f...

Страница 13: ...n shows on the database as well Button 9 It is a functional menu button Press and Hold it to conduct wind speed setting Button Start Next Press Start to mean the first decimal point input Press Next to mean next decimal point during area input and wind count measurement Button Sample Area Measurement in area setting Button Enter Confirmation key See User Setting Stuff Note Under the button 1 9 it ...

Страница 14: ... is as the opening default B Auto Switch Down Press button 8 from AP00 AP01 and store in after power off The default keep it and need to reset when power on C Auto Record REC display on the LCD with the auto recording time between 0 5 255 seconds Press button 2 to extend auto recording time at the bottom of the LCD Press button 8 to reduce auto recording time Press and hold button to store in afte...

Страница 15: ...et when power on D Master Reset LCD shows the DEF with flash You can reset your anemoscopes to the factory settings Press button 2 of to the factory settings for USBO APO1 60S data clearing Press button 9 menu to cancel the factory setting Then enter wind speed measurement ...

Страница 16: ...o FLOW wind count Data Hold Press Hold button to data capture then press again to cancel the data capture feature Wind Speed Measuring Unit Switch Under the wind speed measurement press UNIT button m s ft min KNOTS Km hr MPH in order to random to have the measuring unit switch Wind Count Measuring Unit Switch Under the wind count measurement press UNIT button CMM CFM to have the measuring unit swi...

Страница 17: ...wind count measurement 3 Select the approiate wind count measuring unit The press Sample button to enter area input LCD shows KEYIN blank on the top 4 Enter the data and four digits value then LCD will be manipulated it a new display on the top Example Enter 1 0 0 0 Mean 1000 LCD display 1000 Enter 1 0 0 0 Mean 1 000 LCD display 1 000 Enter 1 ENTET Mean 1 0 LCD display 1 000 ...

Страница 18: ...rent input methods but finally it has one display Data Input Range 0 000 9999 Temperature Measuring Unit Switch Under the wind speed measurement press button and vice versa Maximum Wind Speed Temperature Under the wind speed measurement press MAX MIN button Normal MAX and vice versa Maximum 2 3 Average Wind count Under the wind count measurement press MAX MIN button Normal MAX AVE and vice versa ...

Страница 19: ...tic data storage in LCD also LCD displays REC and around 0 5 seconds to disappear REC signal Then press button 7 the data store in next position 4 Automatic data storage press button 7 LCD display REC and resume it if press button 7 again Fast press button 7 twice Then enter automatic data storage REC signal flash appear Press the setup menu automatic data storage In case of full data storage it e...

Страница 20: ...ly display last data record LCD will be displayed the recording number or recording data LCD display RECNO 1 Press button 2 to increase the reading records Press and Hold to automatically increase the reading records 2 Press button 8 to reduce the reading records Press and Hold to automatically reduce the reading records 3 Press button 4 to increase 100 pieces of records when the database is large...

Страница 21: ...r 10m s under 1 2 minutes duration To carry out anemoscopes follow the following procedure 1 Press on Power button until the anemoscopes on 2 Press VEC FLOW figure 4 to conduct function switch LCD shows either VEL or FLOW 3 Press Button 1 UNIT to conduct measuring unit switch 21 UT361 UT362 OPERATING MANUAL ...

Страница 22: ...ain a more precise reading during the connection between wind speed measurement and wind source 6 Obtain a more precise reading you should move the anemoscope on at least 20 angle degrees in order to get more accuracy 7 When the measurement of wind speed and wind temperature in parallel the secondary display show wind temperature value 8 Press button 6 to conduct temperature unit selection namely ...

Страница 23: ...r Connectivity For UT362 only see figure 5 When use the anemoscopes model UT362 need to connect USB cable with the computer Connect the USB interface cable the anemoscope and the computer as reference to the figure 5 Figure 5 White Computer ...

Страница 24: ...ator appears To replace the battery 1 Turn the anemoscope off and remove all the connections from the input terminals 2 Turn the anemoscope s front case down 3 Remove the screw from the battery compartment and separate the battery compartment from the case bottom 4 Take out the old battery and replace with a new 9V battery 6LF22 Rejoin the case bottom and the battery compartment and reinstall the ...

Страница 25: ...rgent Do not use abrasives or solvents C Service And Repairing This anemoscope is an auto calibration Do not attempt to repair or service your anemoscope unless you are qualified to do so and have the relevant calibration performance test and service information D General Service 1 Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents ...

Страница 26: ... a place of humidity high temperature explosive inflammable and strong magnetic field Environmental Requirements Operating Temperature Range 0 50 32 122 Relative Humidity 0 75 no condensation Storage Temperature 20 65 4 149 Pressure 500mB 2 Bar Safety Compliances Certification EN61326 2006 EN55022 1998 A1 A2 EN55024 1998 A1 A2 ...

Страница 27: ...27 UT361 UT362 OPERATING MANUAL Range 2 10 m s 10 30 m s UT362 3 0 5 3 0 8 UT361 3 0 5 3 0 8 Accuracy Technical Specification Wind Speed Measurement ...

Страница 28: ...28 UT361 UT362 OPERATING MANUAL Temperature Measurement Temperature Main Unit Temperature Sensor Temperature Range 0 40 32 104 0 40 32 104 UT362 3 4 3 4 UT361 3 4 3 4 Accuracy END ...

Страница 29: ...29 UT361 UT362 OPERATING MANUAL This operating manual is subject to change without notice ...

Страница 30: ...30 UT361 UT362 OPERATING MANUAL ...

Отзывы: