UT 331+

UT 332+

  

Turn on/off Backlight

    Short press backlight button to turn on the backlight, press again to turn it off. 
    Long press backlight button to activate alarm, the alarm icon      appears, long 
    press backlight button again to inactivate alarm, the alarm icon disappears.

    With the alarm function activated, the red backlight will flash every 500ms if 
    Meters alarms due to upper limit, the blue backlight will flash every 500ms if 
    Meters alarms due to lower limit. If Meters alarms due to upper & lower limit, the 
    red/blue backlight will flash every 500ms in turn and the corresponding icon will 
    light up, for example, if Meters alarms due to upper temperature limit, the red 
    backlight, temperature icon and upper icon (HI) will flash at the same time.

  

View Max/Min Reading

1. Short press MAX/MIN button to check Maximum reading, minimum reading and 
    normal test value.
2. Long press MAX/MIN to exit the mode.

  

View dew-point temperature and wet bulb temperature

    Short press ENTER to view dew point temperature, wet bulb temperature and 
    normal temperature. For dew point temperature, “DEW POINT” is displayed on 
    the screen, for wet bulb temperature, “WET BULB” is displayed on the screen.

  

Use offset value to adjust Meters error.

    Users can compensate the error in temperature & humidity offset setting of SETUP.

  

Data Access

Store Data

    Manual storage: time interval is set at 00:00, in test page, short press ST ORE 
    to store data manually, Meters flashes and show the storage area. Take LOG 
    001 as an example, it represents the data is stored at 001. UT331+ can store 
    299 groups of data, UT332+can store 999 groups of data, the record data is the 
    data shown in the main display screen.
    Auto storage: time interval is not set at 00:00, in test page, short press STORE 
    to store data manually, long press STORE to store data automatically, the storage 
    area, i.e. LOG 001, will flash at intervals, Meters will automatically save data in 
    circle at the set interval, the record data is the data shown in the main display 
    screen.

  

Recall Data

   Short press RECALL to check recorded data, press again to exit.

1. Short press RECALL to check recorded data, the screen displays the storage 
    area, i.e. LOG 001, press        to scroll through recorded readings, Meters 
    defaults at the reading saved last time you exit the STORE mode.
2. Short pressing ENTER under RECALL mode can quickly review from 01 to 299
    /999 data and also allow you to transfer data to PC through USB, after quick 
    review, the number stops at 299/999. On data reviewing status, short press 
    RECALL to exit and go back to main display screen.
3. Long press RECALL under RECALL MODE to clear the recorded data, the screen 
    will keep displaying dELE until the data is completely cleared, and then go back 
    to main display screen.
    Note: The data will be completely cleared once the function is enabled. Step-by
    -Step clearing is not allowed. To avoid any data loss, please think it twice before 
    you use the function.

  

Transfer Data

    Meters will transfer data to PC under following two circumstances:
1. Enter into RECALL status, short pressing ENTER button will not only allow you 
    to review the data quickly but also transfer the data automatically to PC.
2. When PC is running the supplied software and has been already connected to 
    Meters, the measured data will be automatically transferred to PC.

  

USB power supply

    Connect USB cable to PC USB interface or 5V DC adaptor, Meters will 
    automatically switch to USB power supply. Disconnect the USB cable to switch 
    to battery power supply.
    Note: The DC voltage of USB power supply is 5V, voltage over 5V may damage 
    Meters.

Maintenance

  Replacing the battery (See Figure 3)

When Meters indicates “       ”, please replace the 
battery timely. Follow the steps as below: 
1.Unscrew the battery cover and remove it from 
   Meters.
2.Replace the batteries with new 4×AAA batteries.
3.Rejoin the battery cover and tight up the screw.

Figure 3

     Cleaning the casing

When it becomes necessary to clean the surface of Meters, clean it with soft 
cloth or sponge dampened with just a little of water, soap water or mild detergent. 
Prohibit washing Meters with water directly, which may damage the circuits inside.

View storage data

°C or °F

Users can turn on/off the alarm (It defaults at 

“turn off”). Backlight alarm (For upper-limit alarm, 

the red light flashes every 500ms. For lower-limit 

alarm, the blue light flashes every 500ms.)

Users can view the real-time data through the 

software of master computer and export the 

storage data.

Users can turn on/off the function of auto power 

off (It defaults at “turn on”) and adjust the auto 

power off time (5min

60min).

Set the real time of system.

Temperature, dew point temperature, wet bulb 

temperature, humidity offset value (-6

6).

Users can turn it on/off (It defaults at “turn off”).

Connect USB and switch to USB power 

supply, USB voltage is 5V.

999 groups

Users can turn on/off auto storage(It defaults 

at “turn off”) and adjust the storage 

interval 0s

60min.

Temperature: 0.1°C, Humidity: 0.1%RH

Measurement temperature/Dew point 

temperature/Wet bulb temperature

10%~90%RH, ±3%RH. 

For others: ±3.5%RH.

10%~80%RH, ±2%RH. 

For others: ±2.5%RH.

Measurement 

accuracy

Measurement 

accuracy

Measurement 

range

-20.0°C~

70.0°C

-78.2°C ~

70.0°C

-21.6°C ~

70.0°C

0~99.9%RH

Function

Temperature

Dew point 
temperature

Wet bulb 
temperature

Humidity

Resolution

Temperature measurement

Manual storage

Auto storage

Storage group number

Data viewing

Unit setting

Alarm setting

Max./Min. value measurement

Data hold

Data export

Auto power off

Real time

Offset setting

Backlight

USB power supply

EMC Standard: 

EN61326-1 2013

Reference Standard:

 

JJG205-2005 Mechanical Hygro-Thermometer

JJF1076-2001 Calibration Specification of Humidity Sensor

Technical Index

1. Please download PC software according to the attached general file, and install 
    step by step.
2. After running the master computer software, connect the USB cable to the 
    computer.
3. Browse and analyze data through the master computer software, for the usage 
    of master computer software, please refer “Software Manual” from the Help 
    Option of Operation Page.

USB Communication