Introduction

Structure

 

Thermocouple channel T1, T2, T3, T4 input

USB interface

Display screen

Buttons

Tripod nut

Battery cover

Figure 1

LCD Indicators/Icons

The LCD indicators/icons are shown in Figure 2.

1. Settings
2. Bluetooth communication
3. USB communication
4. Data record
5. Timing measurement mode
6. Auto power off
7. Battery status
8. Primary display of four-channel value
9. Temperature units
10. Time
11. Delete the saved data
12. Offset value compensation
13. Recording interval
14. Thermocouple type
15. Temperature difference between channels
16. Data hold

Short press

Difference between channels/Return

Start/Stop recording the data

Turn on/off the backlight

Data hold/Confirm the setting

Enter the timing measurement 
mode/Up or add the value

Unit switching/Down or 
subtract the value

Long press

Enter/Exit the setting interface

/

Power on/off

/

Exit the timing measurement mode/
Turn on or off the Bluetooth

/

Button

EN

Figure 2

UT325F
4-Channel Thermometer User Manual

Overview

UT325F 4-Channel Thermometer ("Thermometer") is a high- accuracy digital thermometer that uses a 
thermocouple as the temperature probe and comes with a microprocessor.

Features:
    It can work with type K, J, T, E, R, S and N thermocouples.
    With four-channel temperature measurement, the temperature difference can be displayed.
    It can set the time interval to automatically record data.
    72,000 groups of data can be stored.
    Offset value compensation can be set.
    It can connect to a smartphone (Android or iOS) via Bluetooth and edit or view the recorded data and 
    save and export charts in the smartphone APP.
    It can connect to a computer via the USB cable to edit or view the recorded data and save and export 
    charts in the PC software.

Use the thermometer according to the steps in this user manual. Otherwise, the protection provided by 
the product may be impaired.

Safety Instructions

  Warning

A Warning identifies conditions and actions that pose hazards to users. To avoid electric shock or personal 
injury, please follow these instructions.
    Check the housing for broken or missing plastic parts, especially insulation around joints before using 

the thermometer. Do not use the thermometer if it is damaged.

    Disconnect the thermocouple from the thermometer before opening the housing.
    When         is displayed on the screen, replace the batteries as soon as possible.
    If the thermometer is not operating properly, do not continue to use it because the protection provided 

by the product may have been impaired. If in doubt, the thermometer should be sent to a designated 
place for repair.

    Do not use the thermometer near explosive gases, vapors or dust.
    Do not apply voltage between thermocouples or between the thermocouple and the ground terminal.
    When potential difference between thermocouples may occur, an insulating thermocouple should be used.
    Use the specified replacement parts when repairing the thermometer.
    Do not use the thermometer with its housing or cover open.

  Cautions

A Caution identifies conditions and procedures that could cause thermometer damage or equipment 
under test damage. Please use the thermometer carefully.
    Select the appropriate thermocouple, function scale or range scale when using the thermometer.
    When taking multi-channel measurement, it is necessary to ensure that there is no potential difference 

between the two channels.

    Please do not try to charge the batteries.
    Pay attention to the battery polarity when installing.

Setting Interface

In the main interface, long press      to enter the setting interface. The symbol       will show at the top left 
of the screen. Press       or        to step through the setting options. The sequence is: Interval of auto 

recording 

→ 

Saved data and deletion → Thermocouple type → Offset value compensation → Auto 

power off→ Power frequency anti-interference → Time → Restore factory settings.
Long press       to exit the setting interface.

Interface Description

     Interval of auto recording (INTERVAL)

Short press       in this interface, and the second of the time in the lower right corner will blink. Press   
or       to add or subtract the blinking value. Press       to set the value of hour, minute and second in 
sequence.  After setting, short press       to save and return to the INTERVAL interface (If there is no 
operation for a period of time, it automatically exits the modified state). Press       to enter the next setting 
interface.

Note: When the interval is 00: 00: 00, the auto recording function will be disabled and turn into manual 
recording. Press      to record the data once and stop recording.

     Saved data and deletion (MEMORY)

In this interface, only the number of the saved data can be displayed. The information such as the recording 
time and temperature can be viewed in the smartphone APP or PC software. Press      to choose whether 
to delete the saved data or not. The symbol “no” will flash by default. Press       or       to switch between 
“yes” and “no”. When “yes” is flashing, press       to turn into the “doing” interface (deleting). The data will 
be deleted after one minute, and then it will return to the MEMOR Y interface (If there is no operation for 
a period of time, it automatically exits the modified state). In the modified state, press       to return. Press
      to enter the next setting interface.

Note: When “doing” is displayed, it means that it takes a period of time to delete the historical data.

     Thermocouple type (TYPE)

In this interface, short press      , and the thermocouple type of the channel T1 will flash. At this time, 
pressing      or      can switch the thermocouple type. Press       to confirm the selection and to set the 
thermocouple type of the channel T2. Repeat the preceding steps until the channel T4 is set up, and 
press       to save the settings and return to the TYPE interface (If there is no operation for a period of 
time, it automatically exits the modified state). In the modified state, press       to return. Press       to enter 
the next setting interface.

     Offset value compensation (OFFSET)

In this interface, short press       to display the temperature and the ambient temperature (E) of the channel 
T1. The default compensation value “0.0” will flash. At this time, pressing       or       can adjust the 
compensation value of the channel T1. Press       to complete the T1 setting and enter the T2 setting. 
Repeat the preceding steps until the channel  T4 is set up, and press       to save the settings and return 
to the OFFSET interface (If there is no operation for a period of time, it automatically exits the modified 
state). In the modified state, press       to return. Press       to enter the next setting interface.

1.1 Adjust the error of the temperature probe with the offset value
     The reading of the thermometer can be adjusted and the error of a thermocouple can be compensated 
    in the OFFSET interface.
1. Insert the thermocouple into the input jack.
2. Place the thermocouple in a known and stable temperature environment such as an ice bath or dry 
    well calibrator.
3. Let the temperature readings settle down.
4. Change the offset compensation value according to the interface instructions until the temperature 
    reading is the same as the calibrated temperature.

     Auto power off (SLP)

In this interface, short press      to turn on/off the auto power off function. Press       to enter the next setting
interface.

     Power frequency anti-interference (Line)

In this interface, short press      to switch between the power frequency anti- interference type 50Hz/60Hz. 
Press       to enter the next setting interface.

     Time (Y M D h:m:s)

In this interface, short press      to make the value of year/month/day/hour/ minute/second flash. Press   
       or       to adjust the value. When the value of second is flashing, press       , and “SAvE” will show on 
the screen. Press       again to confirm the adjustment, and “donE” will be displayed (If there is no operation 
for a period of time, it automatically exits the modified state). Press        to enter the next setting interface.

     Restore factory settings (Sfr)

In this interface, short press       to choose whether to restore factory settings or not. The symbol “no” will 
flash by default. Press       or        to switch between “yes” and “no”. When “yes” is flashing, press        to 
restore factory settings and return to the main interface (If there is no operation for a period of time, it 
automatically exits the modified state).

See the buttons detail as following