background image

       UT-311 vibration meter is a split portable vibration measurer which consists of acceleration 
sensor and digital measurement display circuit. It is mainly used to measure vibration 
displacement, speed (or intensity) and acceleration of mechanical equipment. Current status 
(such as excellence, notice or danger) can be determined for equipment (such as fan, pump, 
compressor and motor, etc) by above measuring data according to enterprise & machine 
standards by comparing with national metrological verification regulations of JJG 676-2000 
working vibration meter. 
       Such instrument has measuring value locking, low-voltage prompt and automatic shutdown 
functions. With advantages such as wide measurement scope, simple operation and convenient 
carrying, it can be used for patrol detection of equipment vibration in power, metallurgic and 
petrochemical industries widely so it is an ideal tally instrument.

I.INTRODUCTION TO UT311 PRODUCT

Working principle:

Acceleration sensor

Wave filter

Integer I

Adjustment I

Integer II

Adjustment II

AC/DC

A/D

LCD

II.UNPACKING INSPECTION

Please unpack and check if following items are deficient or damaged or not. Please contact 
the nearest sales service agent of our company if there is any deficiency or damage.
1.Host------------------------------------------------------------------1 set
2.Stainless steel measurement rod----------------------------1 (standard) wire assembled to host
3.Hanging rope----------------------------------------------------- 1 (standard) wire assembled to host
4.9V battery----------------------------------------------------------1 section
5.Manual--------------------------------------------------------------1 book
6.Certificate----------------------------------------------------------1 sheet

III.SAFETY NOTICES

Warning: Please pay attention to possible danger and conditions for user or damage 
factors for vibration meter!

Please use vibration meter according to steps shown in the manual or it may be damaged. 
Please abide by following guidelines to avoid instrument damage.
To check if shell is ruptured or lacks of plastic pieces or not before using vibration meter. 
Please do not use vibration meter with damaged shell.
Please replace battery as soon as possible to avoid error of measuring data if battery 
symbol of 

       

 appears.

Please do not continue to use vibration meter which operates abnormally. Please send it to 
fixed repair agent of our company for repair.
Please do not use vibration meter in wet environment with combustible and explosive gas.
Please do not detach shell of vibration meter to avoid damage.
Please do not try to charge battery to avoid personal injury due to battery explosion. 

Содержание UT311

Страница 1: ...P N 110401103774X DATE 2018 06 26 REV 2 ...

Страница 2: ...I Introduction to UT311Product 1 II Unpacking Inspection 2 III Safety Notices 2 IV Instrument Structure 3 V Instrument Setup and Operation 4 VI Technical Indicators 5 VII Maintenance 7 CONTENTS ...

Страница 3: ...unpack and check if following items are deficient or damaged or not Please contact the nearest sales service agent of our company if there is any deficiency or damage 1 Host 1 set 2 Stainless steel measurement rod 1 standard wire assembled to host 3 Hanging rope 1 standard wire assembled to host 4 9V battery 1 section 5 Manual 1 book 6 Certificate 1 sheet III SAFETY NOTICES Warning Please pay atte...

Страница 4: ...placement 1 2 3 Vibration acceleration Vibration speed Vibration displacement 3 Key instructions shown in Figure 1 The 5 element shown in Figure 1 Measurement key button th V INSTRUMENT SETUP AND OPERATION 1 Battery installation Please open cell box on the instrument back and then install 6F22 type 9V laminated cell into cell box Please pay attention to polarity then cover it 2 Power Inspection Pl...

Страница 5: ...n hands after measurement It is not allowed to hoist sensor by signal wires to avoid influence to service life of such wires VI TECHNICAL INDICATORS 1 General Specification LCD display 3 1 2 bit display The maximum display 1999 Under voltage display Sensor type Acceleration sensor Power demand 1 6F22 9V carbon or alkali battery Service life To operate for more than 20 hours continuously Outline di...

Страница 6: ...allation Please install cell cover after installation 2 General Maintenance Please clean dirty instrument shell by wet cloth and neutral detergent Please do not use abrasive or solvent Please send damaged vibration meter to fixed repair agent or professional repair personnel of our company if required Please do not try to repair it individually Please do not scratch or contaminate LCD of vibration...

Страница 7: ......

Отзывы: