 Safety Information 

Thank you for purchasing the product. Before first use, please thoroughly read and 
strictly follow the safety information and precautions listed in the user manual, to 
avoid electric shock or personal injury. 

‹

 The product is used for live working, for the sake of your safety, please follow 

the national safe production regulations and safe operation procedures. 

‹

 Please pay attention to the labeled words and symbols at the front and rear 

panels. 

‹

 Check if the product and its accessories are complete. Do not use if damage, 

exposure or broken wire occurs. It is forbidden to use if rear cover and battery 
cover are not closed in place. Stop use if metal exposure (caused by cracking of 
casing or test lead) occurs during use. 

‹

 Do not measure voltage over 600V. Do not use under strong electromagnetic 

fields. It is forbidden to conduct test in places with inflammable and dangerous 
substances. 

‹

 Be sure that the plug of the lead connects with terminal tightly, and that the 

direction is correct when performing phase test. Remove the test lead from 
measured conductor before disconnecting the test lead with the voltammeter. Do 
not make contact with the terminal by hand, to avoid electric shock. 

‹

 Do not operate the product by wet hand. Avoid rain from dripping on the product. 

It is forbidden to use in damp state. 

‹

 Do not place or keep the product in environments with high temperature, high 

humidity, dew or direct sunlight for a long time. 

‹

 Keep the product surface clean and dry. Do not use clean the product by 

corrosives or coarse materials, please wipe the current clamp mildly by soft cloth 
(i.e. glasses cloth) dipped with rust-proof dehumidifying lubricant. 

‹

 Please refrain the voltammeter and the current clamps from impact and 

dropping. 

‹

 Use the product in specified measurement range and operating environments. 

‹

 Use, disassembly, calibration and maintenance must be performed by 

authorized qualified personnel. 

‹

 The safety warning symbol “

” in the user manual identifies that the operator 

must perform safe operation according to the instructions. 

‹

 The danger symbol “

” in the user manual identifies that the operator must 

strictly perform safe operation according to the instructions. 
 

 

 

 

 

 

 

Содержание UT268B

Страница 1: ...P N 110401111944X UT268B...

Страница 2: ...erating Conditions 4 2 Rated Operating Conditions 4 3 General Specifications 4 4 Performance Specifications 6 VI External Structure 7 VII Operating Instructions 8 1 Power On Off 8 2 Data Hold Cancella...

Страница 3: ...n is correct when performing phase test Remove the test lead from measured conductor before disconnecting the test lead with the voltammeter Do not make contact with the terminal by hand to avoid elec...

Страница 4: ...in electric power petrochemical industry metallurgy railway industrial and mining enterprises scientific and research institute metrology service electric energy charging system relay protection syste...

Страница 5: ...veform of measured signal Sinusoidal wave 0 05 5 Frequency of measured signal 45 65HZ 6 Current amplitude when measuring phase frequency phase sequence power and power factor 20mA 1000A 7 Voltage ampl...

Страница 6: ...er 0 1W Reactive power 0 1VAR Apparent power 0 1VA Power factor 0 001 Current vector sum 1mA Phase sequence If the phase sequence of U1 U2 and U3 or I1 I2 and I3 is positive then the cursor flashes fr...

Страница 7: ...0V 9 99V 0 01V 1 5 rdg 3dgt AC 10 0V 99 9V 0 1V 1 5 rdg 3dgt AC 100V 600V 1V 1 5 rdg 3dgt Current AC 0 0mA 9 9mA 0 1mA 1 5 rdg 3dgt AC 10 0mA 99 9mA 0 1mA 1 5 rdg 3dgt AC 100mA 999mA 1mA 1 5 rdg 3dgt...

Страница 8: ...UT268B...

Страница 9: ...sable data hold When the voltammeter holds data it performs automatic numbering stores the data held currently and displays the numbering of groups i e Save 002 500 groups of data can be stored at mos...

Страница 10: ......

Страница 11: ...sts Single phase testing Connect the measured voltage lines L and N with U1 YELLOW and COM BLACK terminals correspondingly then the current clamp I1 clamps the measured line L U2 GREEN COM BLACK and I...

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ...ely Charger USB cable 1 set User manual 1 pcs The content of this user manual cannot be used as a reason for using the product for special purposes The company is not responsible for other losses caus...

Отзывы: