Press “
▶
” to view data, and to display the stored data of “0001” group automatically. Press
“
◀
” and “
▶
” to move the cursor, press “
” to confirm and return. The tester is designed
with fast viewing function (“+1, -1, +10, -10”), press “
” once to view data by
increment/decrement, move the cursor to “+10, -10” and hold down “
” to view data
by increment/decrement at 100. To exit data viewing mode and return to testing mode,
please move the cursor to “Return” and then press “
”.
6. Battery Replacement
If the battery voltage of the tester is lower than 4.8V, the low battery symbol “
”
is displayed to indicate replacing battery. Loosen the two screws at the battery
cover, open the battery cover, replace with new battery (Note the battery
specification and polarity), rejoin the battery cover, and then tighten the screws.
VIII.
Precautions
1. Do not place or keep the tester in environments with high temperature, high
humidity, dews and direct sunlight for a long time.
2. Remove the battery when not used for a long time.
3. Leave the clamp jaws away from dirt and dust, make sure the clamp jaws open and
close in place.
4. Avoid impact on the clamp jaws, perform regular maintenance on the tester.
Wipe the tester through soft cloth (i.e. cloth for glasses) dipped with anti-rust
dehumidifying lubricant (i.e. WD-40), do not use corrosive agent or coarse material!
5. Avoid interference of electromagnetic field during testing.
IX.
Packing List
Tester
1 pc
Primary current transformer (CT1)
1 pc
Secondary current transformer (CT2)
1 pc
Tool bag
1 pc
Strap
1 pc
Battery (AAA 1.5V alkaline dry batter)
4 pcs
Battery (6F22 9V)
1 pc