26

25

3. Use of the software

3.1 Long press “Rel”to turn on Bluetooth. The Bluetooth symbol flashes if the 
      mobile APP is not connected after Bluetooth is turned on. Find the installed 
      “iDMM2.0” APP icon on the mobile phone and tap the APP to open it. 
      After the APP is turned on, it enters navigation interface, searches “UT117C” 
      automatically, and displays “UT117C” in the “To be connected” list, then 
      select “UT117C” to connect. Or scan the QR code at the multimeter to 
      connect. After successful connection, the Bluetooth symbol is displayed 
      on the LCD always, the measurement results can be displayed through 
      the communication between “iDMM2.0” APP and UT117C, button control 
      can be performed, etc.                               

3.2 The “iDMM2.0” APP has multiple functions including Bluetooth communication, 
      data recording, device management, report generation, data sharing, 
      data synchronizing, and more. Please refer to the use manual of “iDMM2.0” 
      for use of these functions.

4. Uninstallation of the software

Uninstall the software through the uninstallation function of mobile phone.

XV. Use of magnetic hanger (UT-B23)

1. Overview and features

Magnetic hanger, composed of magnet and hanging strap, can be used to 
hang onto power distribution cabinet, photovoltaic combiner box, automobile 
engine hood, and others, allowing for hand-free measurement and helping 
in positioning of meter. The magnetic hanger is suitable for use with UT117C, 
UT15B MAX, UT17B MAX, UT18B MAX, etc.

Magnet

Hanging strap

2. Installation

Select appropriate installation way (install from right or left side, as shown 
below), grip the magnet by hand, put the magnet into plastic housing, and 
rotate the magnet in a suitable direction. The magnet is held tightly due to 
the housing structure and the magnet structure.

Install from right side:

 

 

Install from left side:

Installed with hanging strap form right side

UT117C User Manual

UT117C User Manual

Содержание UT117C

Страница 1: ...UT117C P N 110401111679X High Precision True RMS Digital Multimeter User Manual...

Страница 2: ...end guarantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damages caused by accident negligence misuse...

Страница 3: ...d auto power off and Bluetooth II Features True RMS to ensure accurate measurement of non linearity load The ability to measure 20A 10 seconds of transient measurement LoZ function Low impedance to pr...

Страница 4: ...asured devices and discharge all capacitors completely Before measuring current please check if the fuse of the multimeter is good and switch off the measured current before connecting the multimeter...

Страница 5: ...IEC 61010 1 CAT 600V VII External Structure 1 NCV sensing end 2 LCD display 3 Functional buttons Used to select measurement functions 4 Rotary switch 5 A terminal 6 COM terminal 7 V terminal 8 Holder...

Страница 6: ...our times at a frequency of 2Hz and the auto off function is disabled To restore auto range and auto off function please exit MAX MIN mode If the auto off function is disabled manually the multimeter...

Страница 7: ...ction Composite sinusoidal signal generated by inverter or variable frequency motor can be measured through the LPF function as shown in Figure 6 below Long press SELECT again to exit LPF function 5 W...

Страница 8: ...ent Do not input voltage over 30V DC AC to avoid personal injury Disconnect the test lead with measured circuit after all measurement operations are completed 5 Resistance measurement Figure 6 1 Set t...

Страница 9: ...asurement under ACA mode of current probe the input current amplitude shall be greater than 10 of full range The frequency response is 45Hz 400Hz For range at 600 0A 1mV 1A AC DC The current probe mea...

Страница 10: ...V AC please observe if the conductor of measured electric field is insulated so as to avoid personal injury Even the displayed result is that voltage is not present it does not mean voltage is present...

Страница 11: ...ution Accuracy a of reading b digit Overload protection Input impedance About 10M Range to ensure accuracy 1 100 of range Least significant digit under short circuit 2 digits 600 00mV 0 01mV 1 30 600V...

Страница 12: ...racy 1 100 of range The least significant digit at current range under open circuit is allowed to be 2 Note 10 20 A Perform measurement continuously for 10 seconds at most then stop for 15 minutes at...

Страница 13: ...allowed to be about 5 under short circuit 12 Current probe measurement ACA DCA 600 0A 0 1A 1 8 3 600V AC DC 600 0A 0 1A 0 8 2 ACA DCA Range Resolution Accuracy a of reading b digit Overload protectio...

Страница 14: ...a synchronizing and more Please refer to the use manual of iDMM2 0 for use of these functions 4 Uninstallation of the software Uninstall the software through the uninstallation function of mobile phon...

Страница 15: ...o not keep in environments with high humidity high temperature and strong electromagnetic fields 2 Replace battery or fuse Figure 11 Warning 1 When the symbol shows on the LCD please replace the batte...

Отзывы: