9
MANUAL - UG400 SERIES SPRAY GUN CLEANERS
REVISED 2023-02-22
Prevent Solvent From Entering the Air Passage of Spray Gun:
insert the plastic plug into the air fi tting of the spray gun
as in the photo below. Positive air will fl ow through the
passage way to the cap during cleaning. If the air passage
way has a a male fi tting attach the knurled female nut to
prevent sovlent from entering the air passage way.
This fi tting is located on the chain with the
trigger clamp.
• Close the lid of the spray tank
and turn the "Auto Wash Timer"
clockwise as in photo below
to initiate cleaning. The wash
cycle takes about 60 seconds.
CLEANING COMPONENTS IN THE MANUAL CLEANING TANK
• Disassemble the spray gun and clean the components in the manual tank using the cleaning tools.
The cleaning tools include the brushes in the cleaning kit, the Flow-through brush and the flexible
spigot.
• Activate the Flow-through brush by stepping on the foot pedal.
• Activate the flexible spigot by stepping on a second foot pedal.
• Clean liquid flows through the cleaning tools and returns to wash pail.
Plastic Plug insterted into
the air passage way of the
spray gun