Full Product Warranty

These Uni-ram products have been engineered and manufactured to high performance standards. 
Each unit has been subjected to detailed factory testing before shipment.

This product comes with a one-year full warranty from the date of purchase. Uni-ram Corporation 
reserves the right to repair or replace the unit, free of charge, to the original purchaser if a part is found 
to be defective in material or workmanship as determined by factory service personnel. The items 
listed below under "Conditions of Warranty" as consumables are not covered.

Uni-ram reserves the right to direct the customer to ship the unit collect to the Uni-ram factory or to an 
approved Service Center for repair using the Uni-ram Return Goods Procedure or to repair the unit on-
site. To prevent damage in transport, the purchaser must ship the unit in the original packaging or use 
alternate adequate packaging. All units must be 

shipped clean and free of liquid. 

Diaphragm Pump:

We are pleased to advise that the warranty on the diaphragm pump, the heart of the spray gun 
cleaner, comes with a 2 year replacement warranty. If, in the unlikely event your diaphragm pump fails 
during the first two years of service, call Uni-ram Service at 1-800-417-9133. We will send you a new 
pump free of charge and arrange for the return of your original pump.    

Conditions of Warranty:

As Uni-ram Corporation has no control over the working conditions or circumstances under which the 
purchaser stores, handles or uses the product, Uni-ram makes no warranty or claim, either expressed 
or implied with respect to this product's fitness for any purpose or the result to be obtained from its 
use. This condition applies to the sale of all products and no representative or distributor of Uni-ram 
Corporation has the authority to waive or change these conditions.

This warranty applies only to the original purchaser and does not apply if the unit has been misused, 
overloaded, neglected, altered or used for any purpose other than those specified in the operating and 
installation instructions. Deterioration due to normal wear is not covered by this warranty. Damage due 
to accident, transportation, fire, floods or acts of God is also not covered. Units whose serial numbers 
have been altered or removed are not covered. The warranty is invalid if unauthorized chemicals as 
noted in the manual or liquids with acid content are used in this unit. Unauthorized attempts at self-
repair or alterations by the owner also invalidate this warranty. Interior or exterior finishes are not cov-
ered by this warranty. 

Consumable Items are not covered by this warranty (eg: gaskets, screens, bags, filters, nozzles and 
air jets).

This warranty replaces all other warranties expressed or implied by statute or otherwise.

To make a claim, call Uni-ram Service at 1-800-417-9133 and quote the serial number of the unit.

Содержание UG400 Series

Страница 1: ...USER MANUAL UG400S UG400W AUTOMATIC SPRAY GUN CLEANERS REV 2023 02 22 WWW UNIRAM COM CORPORATION 381 Bentley Street Markham ON L3R 9T2 Tel 1 800 417 9133 sales uniram com ...

Страница 2: ...and the flexible spigot Activate the Flow through brush by stepping on the foot pedal Activate the flexible spigot by stepping on a second foot pedal Clean liquid flows through the cleaning tools and returns to wash pail CAUTIONS AND WARNINGS Always disconnect this machine from power sources before performing maintenance Do not smoke or use near open flames sparks or heat Make sure all ground wire...

Страница 3: ...3 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 Timer Automatic Tank UG400S Manual Tank Foot pedals for Manual Tank ...

Страница 4: ...building Note The pump and metal tube that inserts into each pail are grounded SOLVENT SELECTION The adhesion quality of automotive paint has dramatically improved in recent years The choice of sol vent is critical Only use good quality solvent that formulated for your paint and intended for use with automatic spray guns cleaners DO NOT USE CHLORINATED SOLVENT PAIL SETUP FOR AUTOMATIC TANK See the...

Страница 5: ...IZONTAL POSITION PRE CLEAN Disconnect the spray gun from the air hose The method for the disposable cup is described first followed by Suction Hose Pail for ManualTank Pail for Automatic Tank Foot pedals for Manual Tank Drain Hose Drain Vavle Inside DRAIN VALVE IS OPEN HANDLE IN VERTICAL POSITION ...

Страница 6: ...ht Pull the gun s trigger to flush the solvent through the fluid channel and into the paint waste container not supplied for later disposal PRE CLEAN CONVENTIONAL CUP Disconnect the cap and pour the paint waste into a paint waste container not supplied CLEANING SPRAY GUNS AND CUPS Remove digital air gauge if so equipped Loosen the air cap of the spray gun two full turns Lock the trigger in the open ...

Страница 7: ...STALLING SPRAY GUNS IN TANK Place the spray gun on the nozzle with the cap facing the corner Nozzle Extension for disposable cups Location for Push On Nozzle Extension Caps points to the corner jets Plastic Plug Location for Conventional Cup Automatic Tank Manual Tank Plastic Spigot Brush ...

Страница 8: ...8 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 ...

Страница 9: ...p Close the lid of the spray tank and turn the Auto Wash Timer clockwise as in photo below to initiate cleaning The wash cycle takes about 60 seconds CLEANING COMPONENTS IN THE MANUAL CLEANING TANK Disassemble the spray gun and clean the components in the manual tank using the cleaning tools The cleaning tools include the brushes in the cleaning kit the Flow through brush and the flexible spigot A...

Страница 10: ...its cleaning effectiveness or after approximately 100 cleanings Close the drain valve see photo below Move the large pail out of the cabinet Remove the drain hoses and suction pipe Pour wash liquid from the wash pail into a waste drum for later disposal Rinse out the pail Remove the small pail and add solvent such that the small pail has 2 gallons of liquid Return the small pail with suction tube i...

Страница 11: ...11 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 TROUBLE SHOOTING ...

Страница 12: ...12 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 ...

Страница 13: ...there is a steady hissing sound and the pump is not cycling the spool valve has stalled due to a blocked air pas sage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the diaphragm pump Use a blow gun to blow air into the open end of this hose Turn timer If the procedure is successful the pump wil...

Страница 14: ...14 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 UG4000E FLOW DIAGRAM Use the diagram to trace the flow of compressed air and solvent ...

Страница 15: ...15 MANUAL UG400 SERIES SPRAY GUN CLEANERS REVISED 2023 02 22 ...

Страница 16: ... for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the product Uni ram makes no warranty or claim either expressed or implied with respect to this product s fitness for any purpose or the result to be obtained from its use This condition applies to the sale ...

Отзывы: