background image

5

MANUAL -  UG110 SERIES GUN CLEANERS    

 

 

 

REVISED 2020-06

vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with 
automatic spray guns cleaners. 

SOLVENT PAIL SETUP

•  Close the Drain Valve under the unit (handle in horizontal position) if it is not already closed. 
•  Place a 5-Gal (19 L) pail of solvent under the unit and insert the Suction Tube and the Drain Tube.
•  Open the Drain Valve (handle in vertical position).

OPERATION
PRE - CLEAN

 

•   Disconnect the spray gun from the air hose. Pour paint from the cup (when present) into a 5 gallon 

pail (not supplied). 

•  Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling.

CLEANING SPRAY GUNS AND CUPS

•  Loosen the air cap of the spray gun two full turns.
•  Lock the trigger in the open position with the Trigger Lock Spring.
•  Plug air inlet of spray gun with cap to prevent solvent from entering passage. Caps are supplied in the 

accessory kit.

•  Place spray guns facing corner jets. Placement depends on type of spray gun (see below). Place cups 

onto the low spray jets and cup holders.

•  Close the lid and turn the “Auto Wash Timer” knob clockwise to start cleaning. The cleaning cycle 

takes about 60 seconds 

WASH TANK 

Nozzle 
Extension

Placing Spray Gun on 
Nozzle Extension
 

Location for cap of 
conventional cup

Cap points to
 the corner jets

Location for  
conventional cup

Содержание UG110

Страница 1: ...Revised 2020 06 USER MANUAL UG110 UG110V UG110VP SPRAY GUN CLEANERS UG110 WWW UNIRAM COM CORPORATION 381 Bentley Street Markham ON L3R 9T2 Tel 1 800 417 9133 sales uniram com...

Страница 2: ...4 LOCATION 4 LEVELING MOISTURE FILTER AND AIR SUPPLY 4 SOLVENT SELECTION 5 SOLVENT PAIL SETUP 5 OPERATION 5 PRE CLEAN 5 CLEANING SPRAY GUNS AND CUPS 5 AFTER CLEANING 6 UG110VP ONLY 6 DAILY MAINTENANCE...

Страница 3: ...3 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 UG110 Drain Hose rear Suction Hose Diaphragm Pump Drain Valve inside Timer Comercial Pail of solvent provided by the User Wash Tank inside...

Страница 4: ...cover on the Air Input right side of machine and to ensure that the air supply is clean and dry attach an Airline Filter not supplied Attach an air supply adapter not supplied to the Airline Filter Th...

Страница 5: ...lied Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling CLEANING SPRAY GUNS AND CUPS Loosen the air cap of the spray gun two full turns Lock the trigger in the...

Страница 6: ...bottom of the tank and clean when necessary Drain and flush the Moisture Filter allowing air under pressure to flow through it REPLACING SOLVENT Close the Drain Valve under the unit Remove the Suction...

Страница 7: ...ERATOR MAIN TAINS TANK Solvent lacks cleaning strength Replace solvent with solvent that is for mulated for type of paint used and for use with automatic spray gun cleaning GUNS NOT CLEAN PUMP WORKING...

Страница 8: ...issing sound and the pump is not cycling the spool valve has stalled due to a blocked air passage Follow the pro cedure below to clear the blockage Connect a blow gun to an 60 PSI source Locate the bl...

Страница 9: ...9 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 FLOW DIAGRAMS Use to trace the flow of compressed air and water...

Страница 10: ...Holder 100 413F Mechanical Timer Assembly 5 minutes 115 200 K Trigger Clamp and Plug Kit 140 2341 Rotating Spray Jet 140 340S Ground Wire 18G Green 4 FT 100 835 Ground Wire Suction Tube 100 8335 Lid s...

Страница 11: ...free of charge and arrange for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stor...

Отзывы: