5
MANUAL - UG110 SERIES GUN CLEANERS
REVISED 2020-06
vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with
automatic spray guns cleaners.
SOLVENT PAIL SETUP
• Close the Drain Valve under the unit (handle in horizontal position) if it is not already closed.
• Place a 5-Gal (19 L) pail of solvent under the unit and insert the Suction Tube and the Drain Tube.
• Open the Drain Valve (handle in vertical position).
OPERATION
PRE - CLEAN
• Disconnect the spray gun from the air hose. Pour paint from the cup (when present) into a 5 gallon
pail (not supplied).
• Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling.
CLEANING SPRAY GUNS AND CUPS
• Loosen the air cap of the spray gun two full turns.
• Lock the trigger in the open position with the Trigger Lock Spring.
• Plug air inlet of spray gun with cap to prevent solvent from entering passage. Caps are supplied in the
accessory kit.
• Place spray guns facing corner jets. Placement depends on type of spray gun (see below). Place cups
onto the low spray jets and cup holders.
• Close the lid and turn the “Auto Wash Timer” knob clockwise to start cleaning. The cleaning cycle
takes about 60 seconds
WASH TANK
Nozzle
Extension
Placing Spray Gun on
Nozzle Extension
Location for cap of
conventional cup
Cap points to
the corner jets
Location for
conventional cup