background image

MANUAL -  UG110 SERIES GUN CLEANERS    

 

 

 

REVISED 2020-06

4

SETUP

INSPECTION AND ASSEMBLY

 

Report any transport damage immediately to the carrier and your vendor. Initiate a freight claim with 
the carrier. The manufacturer is not responsible for freight damage.

•  Remove the machine from the carton by opening the bottom flaps and sliding the carton up over the 

machine. 

•  Make sure the bag of accessories contains the following:
•  Manual
•  Kit-Plug, Guns w. Trigger Lock Springs, 2 pieces (Part No. 140-2340)
•  Nozzle Adapters:
 

110-430 

Push-on, conventional systems only

 

110-430PPS Push-on, disposable cup or conventional systems

Note: Adapter #780-3530 is installed for use with disposable cup system only 
If any item is missing, contact your supplier.     
GROUND WIRE INSTALLATION
•  For safety, two ground wires are provided to discharge static electricity. One is already installed be-

tween the the body and the Suction Pipe.The other must be attached at one end to the outside of the 
body (the screw near the Air Input is recommended) and, at the other end, to an external grounded 
object (see page 4).

DO NOT OPERATE THE UNIT UNLESS BOTH GROUND WIRES ARE SECURELY CONNECTED

LOCATION

Position in a well-ventilated area away from sparks, heat and open flames.

LEVELING, MOISTURE FILTER AND AIR SUPPLY

•  Level the machine using the adjustable feet.
•  Remove the cover on the "Air Input" (right side of machine) and, to ensure that the air supply is clean 

and dry, attach an Airline Filter (not supplied).

•  Attach an air supply adapter (not supplied) to the Airline Filter.
The air supply pressure must be at least 85 PSI and
the air must be free from contaminants such as water, dust, rust, tar, grease etc.

T

o prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been installed to 

limit the air pressure to precisely  85 PSI. Do not install a second air pressure regulator or use a  pres-
sure set below 85 PSI.
See the section, Daily Maintenance, for proper maintenance of the Air Filter Assembly.

SOLVENT SELECTION

The adhesion quality of automotive paint has dramatically improved in recent years. The choice of sol-

INTRODUCTION

Uni-ram holds many patents on designs used in its innovative products. Every machine is tested 
for compliance with Quality Assurance standards. Follow the directions in this manual under Setup, 
Operation and Maintenance in order to operate this machine safely and effectively. Not following these 
instruction can lead to malfunction or damage to the machine. Follow directions under the section 
below, Cautions and Warnings and on labels attached to the machine. Ensure that the manual is read-
ily available to the operator at all times. If you have any questions about the operation of this machine, 
call your distributor or a Uni-ram Service Engineer: 

North America: Uni-ram Technical Service 1-800-417- 9133

Other Continents: Contact Your Supplier

Содержание UG110

Страница 1: ...Revised 2020 06 USER MANUAL UG110 UG110V UG110VP SPRAY GUN CLEANERS UG110 WWW UNIRAM COM CORPORATION 381 Bentley Street Markham ON L3R 9T2 Tel 1 800 417 9133 sales uniram com...

Страница 2: ...4 LOCATION 4 LEVELING MOISTURE FILTER AND AIR SUPPLY 4 SOLVENT SELECTION 5 SOLVENT PAIL SETUP 5 OPERATION 5 PRE CLEAN 5 CLEANING SPRAY GUNS AND CUPS 5 AFTER CLEANING 6 UG110VP ONLY 6 DAILY MAINTENANCE...

Страница 3: ...3 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 UG110 Drain Hose rear Suction Hose Diaphragm Pump Drain Valve inside Timer Comercial Pail of solvent provided by the User Wash Tank inside...

Страница 4: ...cover on the Air Input right side of machine and to ensure that the air supply is clean and dry attach an Airline Filter not supplied Attach an air supply adapter not supplied to the Airline Filter Th...

Страница 5: ...lied Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling CLEANING SPRAY GUNS AND CUPS Loosen the air cap of the spray gun two full turns Lock the trigger in the...

Страница 6: ...bottom of the tank and clean when necessary Drain and flush the Moisture Filter allowing air under pressure to flow through it REPLACING SOLVENT Close the Drain Valve under the unit Remove the Suction...

Страница 7: ...ERATOR MAIN TAINS TANK Solvent lacks cleaning strength Replace solvent with solvent that is for mulated for type of paint used and for use with automatic spray gun cleaning GUNS NOT CLEAN PUMP WORKING...

Страница 8: ...issing sound and the pump is not cycling the spool valve has stalled due to a blocked air passage Follow the pro cedure below to clear the blockage Connect a blow gun to an 60 PSI source Locate the bl...

Страница 9: ...9 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 FLOW DIAGRAMS Use to trace the flow of compressed air and water...

Страница 10: ...Holder 100 413F Mechanical Timer Assembly 5 minutes 115 200 K Trigger Clamp and Plug Kit 140 2341 Rotating Spray Jet 140 340S Ground Wire 18G Green 4 FT 100 835 Ground Wire Suction Tube 100 8335 Lid s...

Страница 11: ...free of charge and arrange for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stor...

Отзывы: