3
MANUAL - SOLVENT RECYCLERS - URS1600 SERIES, URS2000 SERIES & RI 80 Rev 2019-05
FEATURES AND SPECIFICATIONS
All Uni-ram Solvent Recyclers feature
rapid-start
direct electric heating of solvent and a
short cool-
down time
due to high-effi ciency condensers and air cooling with a motor driven fan.
MODEL
URS2000SS
URS2000PW
URS2000SS-TE
RI80
URS1600SS
VOLTAGE (V) SINGLE
PHASE
220/240*
220/240*
220/240*
220/240*
220/240*
BRANCH CIRCUIT
AMPS
30
30
30
30
30
MAX TEMPERATURE
SET POINT
200°C
240°C**
200°C**
240°C**
200°C
TIME TO RECYCLE
8-10 HOURS
8-10 HOURS
8-10 HOURS
8-10 HOURS
8-10 HOURS
TANK CAPACITY
20 US GAL
(80L)
20 US GAL
(80L)
20 US GAL (80L)
20 US GAL
(80L)
16 US GAL
(60L)
LID GASKET
NEOPRENE
NEOPRENE
TEFLON
VITON
NEOPRENE
LINER BAGS
YES
YES
YES
NO
YES
SHIPPING DIMEN-
SIONS (WDH”)
47 X 27 X 50
47 X 27 X 50
47 X 27 X 50
47 X 27 X 50
43 X 27 X 50
WEIGHT (LB/KG)
450/205
450/205
450/205
450/205
420/145
Safety Features:
•
Certifi ed
to UL standards U2208 and CSA standards C22.2 No. 30 and No. 88 by ETL. Approved
for use in non hazardous locations as well as approved for use in hazardous locations Class 1,
Division 1, Group D and Class 1, Division 2, Group D.
•
Explosion proof construction
and intrinsically safe electric circuitry.
•
Computer controlled
with many built-in safety programs including temperature control of all criti-
cal points including tank, condenser and fan motor. Power is cut when the temperature at any of
these points rises above a pre-set level. Operation also terminates when other abnormal conditions
exist (eg: boiling does not start on time or the distillation process takes too long).
•
Automatic pressure relief
lid system prevents pressure in the Distillation Tank from exceeding 0.5
to 1.0 psi. (0.035 to 0.070 kglcm2).
•
Self Diagnostic
error messages are displayed on the Display Panel.
•
Dual lid
cover system.
•
Compact, enclosed cabinet
for safe storage of the Solvent Receiving Container inside the cabinet.
*Note on VOLTAGE:
Operating the unit at VOLTAGE lower than 220V
(eg: 208V) may result in reduced performance.
**Note on MAX TEMPERATURE SET POINT:
If a Liner Bag is used, do not use a SET POINT
greater than 205 °C.