Tel: 888-994-0895
Tel: 888-994-0895
Installation, Operation & Service Instructions
Installation, Operation & Service Instructions
Uni-P Pro 120X Dehumidifier
Uni-P Pro 120X Dehumidifier
Remote Control Instructions
Unipdry Dehumidifiers can be controlled using an optional remote accessory. The remote
connects to your dehumidifier via a 25’ CAT 5 cable, with the integrated sensor giving you
multiple options for monitoring surrounding conditions.
Example #1- Install the dehumidifier in the laundry room and duct it into the living room.
Mount the remote in the living room and use the remote sensor.
Example #2- Install the dehumidifier in your crawl space with the remote mounted in
your garage.
NOTE: The symbols indicated below only
show when the remote is powered on.
1
.
On/Off (Power) Button
Press the on/off button and the machine
will start running. Press the button again
to turn the machine off.
2.Up Button/ Down Button
Use the up and down arrows to
adjust the humidity level.
3.Mode
Use the mode button to switch between dehumidifier and a ducted
application.
• The symbol on the display indicates the sensor on the remote
control is being utilized.
• The symbol on the display indicates the sensor on the dehumidifier
is being utilized.
4. Temperature
The T button changes the temperature reading on your remote. The
remote comes from the
factory in Celsius. Press this button once to
switch to Fahrenheit.
5. Continuous
Press this button to switch the unit into continuous mode. “CONT.” will
appear on the
display screen.
6. Drain Pump
Use this button if the unit will not be used for an extended period of time.This button will
remove water from the pump reservoir.
Remote Control Instructions
1
.
Start the machine
•
Press the power key to turn the dehumidifier on.
2
.
Adjust the settings
• Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%)
3
.
Stop the machine
• Press the power button again and the dehumidifier will stop. Note that the fan will continue to
operate for 1 minute after the unit has shut off. DO NOT DISCONNECT THE POWER CORD
TO FORCE THE UNIT TO STOP.
4. Water Drainage
• The Unip Pro 120X has an integrated condensate pump.During normal operation, the
Pro 120X will automatically drain as required.
• If you would like to store or move your unit, press the drain button to drain water from the
pump reservoir. The drain will operate for 15 seconds each time the button is pushed. It may
be necessary to push the button more than once.
6
7