7.  I/O Interfaces 

7.1. Antenna Interfaces 

7.1.1.  Connectors 

The VTX-301 provides two 

50 Ω RF connectors. Receptacle connectors are compatible 

with 

I-PEX  MHF  I  20279-001E-03

  or 

HIROSE  U.FL-R-SMT-1(10)

.  For  more  information 

about  mating  connectors,  visit  the  websit

https://www.i-pex.com/Products/detail/129

  or 

http://www.hirose-connectors.com/

 for more detail. 

 

Figure 3: Antenna connectors 

The antenna connection is one of the most important aspect in the full product design 

as it strongly affects the RF performance. Connecting cables between the module and the 

antenna must have 50 Ω impedance. If the impedance of the module is mismatched, RF 

performance will be reduced significantly. 

Please be careful when extracting the antenna cable from the VTX-301. Extracting the 

connector  by  pulling  the  cable  may  cause  damage  on  the  antenna  plug  assembly.  It  is 

recommended to extract the cable using extraction tool like 

I-PEX 90192-001

 or 

HIROSE 

U.FL-LP-N-2

V2X0 ANT 

MHF I, 

50 Ω 

V2X1 ANT 

MHF I, 

50 Ω 

Содержание VTX-301

Страница 1: ...1 Revision 0 3 Authors Nidor Huang Quick Start Guide for VTX 301 Reviewers Department Name Acceptance Date Note PD Nidor Huang 2020 4 7 RD JY Ou Modification History Revision Date Originator Comment 0...

Страница 2: ...mmission Interference Statement 4 4 4 Modular approval RF Exposure 5 4 5 Labelling Requirements for the Host device 5 5 Product Appearance 6 6 Functional Block Diagram 6 7 I O Interfaces 7 7 1 Antenna...

Страница 3: ...ce Unex VTX 301 datasheet Hirose U FL series catalog I PEX MHF Micro RF coax connector product series catalog 3 Safety Guideline Do not touch the module while power is applied Hold the module by its e...

Страница 4: ...on warming as shown in this manual 4 3 Federal Communications Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant...

Страница 5: ...distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter End users and installers must be provide with antenna installa...

Страница 6: ...1 6 11 A printed version of this document is an uncontrolled copy 2020 Unex Technology Corporation Company Confidential 5 Product Appearance Figure 1 Appearance 6 Functional Block Diagram Figure 2 Fun...

Страница 7: ...connectors com for more detail Figure 3 Antenna connectors The antenna connection is one of the most important aspect in the full product design as it strongly affects the RF performance Connecting c...

Страница 8: ...2 Pinout Please note that the pinout listed here is seen from the VTX 301 side For designing a system board interface the input and output direction must be reversed Typical internal PU PD resistor is...

Страница 9: ...PU 8 Ethernet MAC Interface Tx Clock VDD_3 3V 32 GND G Ground 33 ETH0_TX0 O PU 8 Ethernet MAC Interface Tx Data line 0 VDD_3 3V 34 ETH0_TX1 O PU 8 Ethernet MAC Interface Tx Data line 1 VDD_3 3V 35 ET...

Страница 10: ...5200bps 8N1 VDD_3 3V 69 UART3_RXD I PU 4 UART Interface Receive input console 115200bps 8N1 VDD_3 3V 70 N C Non Connection 71 N C Non Connection 72 N C Non Connection 73 N C Non Connection 74 GND G Gr...

Страница 11: ...fill the air gap between VTX 301 and its system board could help disperse heat generated by the VTX 301 to the system board It is recommended to keep continuous large copper pour area on the system PC...

Отзывы: