background image

Installation:

Select a location that affords good access to the ballast box. Preferably the ballast box should be placed in a cool, dry and well

ventilated area. Attach the ballast box to a fixed wall or similar secure structure using appropriate M6 fasteners. Note: Whereas,

the ballast box can be placed in any orientation, it is recommended that the cable strain relief connectors face down.

Using marine grade cable, run a VAC input line into the ballast box and secure by way of one cable strain relief connector.

Using a high temperature 18/3 shielded silicone cable, run a line from the ballast box to the underwater light and secure each end

by way of a strain relief connector. Caution! Avoid making tight bends and/or passing cable over sharp edges/surfaces.

Connect cable leads at both the ballast box and underwater light as shown in the wiring diagram below.

Serviceable Parts:

Upon opening the ballast box by unscrewing four captive lid fasteners, replacement of the HID ballast and/or terminal block with

fuse is accomplished by removal and replacement of three phillips pan head screws and associated wiring. Further, a 10 Amp fuse

located in the fused terminal block may be pulled out and replaced as required. Caution! Ensure that VAC power is disconnected

and locked out before servicing ballast box.

SV18 Ballast Box

120VAC/150W

240VAC/150W

Underwater Lights Europe Sarl

16, rue Rouaze

06400 Cannes, France

Phone: 33-(0)-4-97-21-02-96

Fax: 33-(0)-4-97-21-10-96

Internet: www.seavision.com

Underwater Lights USA, LLC

 

3406 SW 26th Terrace, C-6/7 

Fort Lauderdale, FL 3331

2

 USA

 

Phone: 1-954-760-4447

Fax: 1-954-525-3261

 

Internet: 

www.seavision.com

 

Email: 

[email protected]

DOC:092005-11

Email: [email protected]

FAST BLOW FUSE

18013

M3.5 x 0.6 x 12LG PPHS

18011

M4 x 0.7 x 8LG SST PPHS

18010

M6 x 1.0 x 8LG SST PPHS

18009

FUSED TERMINAL BLOCK

18008

240VAC BALLAST, MODEL 11A16B

18007

120VAC BALLAST, MODEL 10A16B

18006

BLANKING PLUG

18005

CABLE STRAIN RELIEF

18004

TERMINAL BLOCK MOUNT

18003

MOUNTING PLATE

18002

ENCLOSURE, PLASTIC

ENCLOSURE, ALUMINUM

18001
18020

DESCRIPTION

PART

120VAC BALLAST, MODEL 10A19B

18017

240VAC BALLAST, MODEL 11A19B

18018

16/3 HIGH TEMP SHIELDED SILICONE ELEC CABLE

18019

MODELS 10A16B & 10A19B, 120VAC/150W
MODELS 11A16B & 11A19B, 240VAC/150W

8-18 x 6LG THREAD FORMING SST PPHS

18021

GROUND WIRE ASSEMBLY

18022

Содержание Sea Vision SV14

Страница 1: ...or specific requirements please contact us Note Please specify voltage when ordering All information is subject to change without prior notice please confirm details prior to ordering aluminum weld in...

Страница 2: ...ng and ballast box should be visually inspected for proper operating condition every six months Marine growth should be removed from the glass using a soft brush to allow both heat and illumination to...

Страница 3: ...tightened to 2 Nm 1 5 ft bs Note Upon completing light installation it is highly recommended that the Front Flange 18 be coated with antifouling paint Serviceable Parts Lamp replacement is done by rem...

Страница 4: ...0VAC 150W Underwater Lights USA LLC Underwater Lights Europe Sarl 3406 S W 26th Terrace C 6 7 16 rue Rouaze Fort Lauderdale FL 33312 USA 06400 Cannes France Phone 1 954 760 4447 Phone 33 0 4 97 21 02...

Страница 5: ...20VAC 150W 240VAC 150W Underwater Lights USA LLC Underwater Lights Europe Sarl 3406 S W 26th Terrace C 6 7 16 rue Rouaze Fort Lauderdale FL 33312 USA 06400 Cannes France Phone 1 954 760 4447 Phone 33...

Страница 6: ...r coated diecast aluminum alloy with integral silicone rubber gasket IP66 NEMA 4X rated Ballast 120 VAC 50 60 Hz 1 38 Ampere input 150 Watt output Minimum operating temperature 30 C 22 F OR Ballast 24...

Страница 7: ...e phillips pan head screws and associated wiring Further a 10 Amp fuse located in the fused terminal block may be pulled out and replaced as required Caution Ensure that VAC power is disconnected and...

Страница 8: ...ssono essere utilizzati esclusivamente per il lavoro contratto o mediante espressa autorizzazione scritta della Underwater Lights USA LLC Ci vale sia per la prima utilizzazione sia per il materiale in...

Отзывы: