background image

Tracker

2

 Assembly & Operating Instructions 

Introduction  

Congratulations on your purchase of Underhill’s newest generation of portable irrigation machine 

Tracker

2

.  Now more streamlined with the following unique features: 

 

328 ft. (100m) of galvanized steel pull cable, 

 

Simplified gear drive assembly for longer life and consistent performance, 

 

Nearly fully assembled in the box, simply install the included part-circle impact sprinkler, 

 

Connect a 1” minimum sized hose, 

 

Spool out the cable wire and place the included ground stake of where irrigation is to finish, 

 

Turn on your water supply and step-back.   

 

Please take a few moments and read the following Assembly and Operating Instructions to 

familiarize yourself with this product.   

Applications  

The Underhill Tracker

2

 is a self-propelled, portable irrigation machine that can be used for a wide 

variety of supplemental irrigation when required.    

 

The Tracker

2

 can pull itself up to 328’ in length from point A to point B.  It comes supplied with 

galvanized steel pull cable and ground stake.  A minimum of 1” supply hose should be about 10% 

longer than the length of area to be irrigated depending on the water source.   

 

The Tracker

2

 comes standard with a part-circle impact sprinkler with a radius of 62 feet (18,9m) 

depending on the delivery pressure to the inlet end of the Tracker

2

.  The part circle sprinkler can be 

converted to a full-circle model by sliding the trip pin upwards while the sprinkler is set to the 

forward mode and not the reverse mode.   
 

Warning:  The Tracker

2

 requires a minimum of 50 Psi water pressure at the inlet end 

of the machine. 

General Instructions for Safety and Accident Prevention  

Develop early and safe habits each time operating the Tracker

2

 Portable Irrigation Machine, please 

check the machine and supply hose.  In general: 

 

Please take a moment and read through these Assembly and Operating instructions prior to 

operating this machine.  

 

Before starting, check the immediate visually check the surroundings for children and/or site 

features that might obstruct the Tracker

2

’s path. 

 

Working in close proximity to areas to be irrigated is not recommended, 

 

The sprinkler nozzle while operating should not be pointed directly at anyone.   

 

Standard safety measures are to be observed when any low overhead or on-grade wires might 

exist within the Tracker

2

’s sphere of irrigation spray.  Contact your local electric or power 

company to obtain advice about safe operating distances if any potential danger exists.  

Содержание Tracker 2 T-400-2

Страница 1: ...T 400 2 Portable Irrigation Machine Assembly and Operating Instructions Underhill International Corporation Irvine CA USA 866 863 3744 www underhill us ...

Страница 2: ...RODUCTION 3 APPLICATIONS 3 GENERAL INSTRUCTIONS FOR SAFETY AND ACCIDENT PREVENTION 3 BEFORE USE 4 RECOMMENDED TOOLS FOR ASSEMBLY 4 GETTING STARTED 4 WINTERIZATION 7 SPECIFICATIONS 7 PRODUCT DIMENSIONS 7 IMPACT SPRINKLER PERFORMANCE CHART 8 HOSE FRICTION LOSS CHART 8 ...

Страница 3: ...g on the water source The Tracker2 comes standard with a part circle impact sprinkler with a radius of 62 feet 18 9m depending on the delivery pressure to the inlet end of the Tracker2 The part circle sprinkler can be converted to a full circle model by sliding the trip pin upwards while the sprinkler is set to the forward mode and not the reverse mode Warning The Tracker2 requires a minimum of 50...

Страница 4: ...t sprinkler which is included in the shipping carton but not assembled Getting Started The following are set up instructions of the machine initial and periodic use 1 Locate the sprinkler inlet at the top of the Tracker2 machine see Figure 4 1 Wrap the male end of the impact sprinkler with two full turns of Teflon tape Initially hand thread and tighten the sprinkler into the sprinkler inlet Use an...

Страница 5: ...ed and nearest the water supply Consider the radius of the impact sprinkler and delivery pressure to determine the Tracker s final position particularly considering prevailing winds 5 Layout the hose parallel to the travel direction of the Tracker see Figure 5 2 below Now make the hose connection to your water supply Verify the hose is free of dirt debris and sand by flushing the hose from the wat...

Страница 6: ...t be OFF while the Quick Closing Valve is opened 9 Open the water supply Verify the working or delivery water pressure and water flow is sufficient The Tracker2 will start to pull itself along the pull cable by the on board turbine and gear box 10 Located at the end of the pull cable is a Stopper see Figure 7 1 This presses the switch off lever to close the quick closing valve once all of the pull...

Страница 7: ...have collected within the machine using compressed air This can be accomplished by temporarily removing the impact sprinkler and blowing air back through the hose inlet port Then clean and lubricate wheel axles cable drum pull cable locking mechanism and winder handle connection into the main body of the machine Specifications Product Dimensions Length 32 1 2 0 83m Width 18 0 46m Overall Height w ...

Страница 8: ...approx 60 meters 260 approx 80 meters 325 approx 100 meters 1 4 6 4mm 51 Psi 6 0 Psi Loss 15 6 Psi Loss 19 5 Psi Loss 65 Psi 6 2 Psi Loss 16 0 Psi Loss 20 Psi Loss 67 Psi 6 5 Psi Loss 16 5 Psi Loss 21 Psi Loss Notes 1 The Tracker2 requires a minimum of 50 Psi to the inlet end of the machine after all losses calculated through the length of hose to be used 2 diameter 6 4mm nozzle is the standard no...