background image

 

QSx Operating Manual 

28 

C6054101 (June 2020)

 

The screen displays: 

“Unit Overheat”

 

“Please Wait”

 

“Switch Off to”

 

“reset”

 

“menu”

 

The  QSx  has  detected  that  the  ultrasonic 
generator on the unit has operated above the 
rated  temperature  and  has  disabled  the 
ultrasonic  function.  This  also  disables  a  cycle 
from  starting.  The  most  likely  cause  is  the 
liquid  evaporating  when  the  level  sensor  is 
switched off. Switch the unit off, allow the unit 
to  cool  for  a  few  minutes,  top  up  the  liquid 
above  the  level  sensor  and  switch  the  unit 
back on. 

The screen displays: 

Over Temp 

The QSxhas detected that the water in the 
bath is above 75ºC and has aborted the cycle. 
Please allow the liquid to cool or drain some 
fluid and replace with cooler liquid. 

 

If your problem persists, it may be possible to rectify any issues over the 
telephone.  Our  dedicated  service  and  product  support  personnel  may  be 
able  to  troubleshoot  your  problem  remotely,  thus  causing  minimal 
disruption. 

Contact our After Sales Department: 

+44 (0) 845 330 4238 

 

+44 (0) 2920 83 7336 

 

[email protected]

  

 

Please  have  to  hand  your  model  and  serial  number  together  with 
information on the problem prior to contacting us. 

If  we  are  unable  to  solve  your  problem  over  the  phone,  we  may  suggest 
returning  your  product  to  the  distributor  where  purchased  or  directly  to 
Ultrawave.  Where  appropriate,  we  operate  a  Return  To  Base  (RTB) 
warranty and repairs policy. 

Содержание QS Series

Страница 1: ...le 14 Cycle abort modes 15 Cycle abort modes 16 Advanced menu 17 Ultrasonic cleaning detergents 23 Technical information 24 Specifications 25 Troubleshooting and Problem Solving 27 Returning equipment...

Страница 2: ...in BS1363 plug Always connect to a fully earthed supply using the moulded plugs provided It can be dangerous to operate an ultrasonic bath without an earth connection The unit is supplied with a remov...

Страница 3: ...emperatures as external surfaces may become hot Never use toxic flammable acidic caustic or corrosive solutions in the bath Do not move the bath when it contains water Before cleaning drain the bath C...

Страница 4: ...rgent sachets 1x power cable How to install Screw the hose connector into the drain valve at the rear of the unit Locate the QSx close to a drain or sink Connect one end of the drain hose to the hose...

Страница 5: ...ower on off switch at the rear of the unit The switch will then illuminate The QSx is operated through a menu driven control system The different keys perform the following functions KEY 1 Starts and...

Страница 6: ...he basket from the bath and rinse the items under clean running water The lid can be inverted and the basket placed on top to catch excess liquid as the items dry REMEMBER Always ensure the liquid is...

Страница 7: ...he temperature set the message Temp OK will display The actual temperature in the bath will vary and will be different to the value shown in the screen above To immediately start the cycle using the a...

Страница 8: ...on page 24 You will need to degas the liquid to ensure good cleaning efficacy By choosing YES your QSx ultrasonic bath will run an automatic de gas cycle The following screen will display The degassin...

Страница 9: ...he various changeable parameters press the MENU key when the following screen is displayed To scroll through the menu press the MENU key To exit the MENU at any time press the key Your QSx remembers t...

Страница 10: ...c bath will only operate when the bath is full of liquid Please note that during normal operation ultrasonic energy will heat the cleaning liquid by up to 15 C per hour Your QSx ultrasonic bath cannot...

Страница 11: ...up to 99 minutes When the desired cycle time has been selected use the MENU key to move to the next screen Screen 3 Setting the power level Your QSx ultrasonic bath allows the power level of the ultr...

Страница 12: ...rst turned on allowing you to run a degas cycle whenever a cleaning cycle is initiated Use the ON and OFF keys to select the required option See page 24 for the importance of degassing If you turn the...

Страница 13: ...a wider frequency range reducing standing waves and improving the cleaning action For different cleaning applications the operator can choose between Frequency LEAP and traditional ultrasonic activit...

Страница 14: ...o begin the cleaning cycle When the QSx is in operation the following screen will display This screen is only an example The actual time and temperature shown will be the time as set by the operator a...

Страница 15: ...vel sensor is set to ON see page 20 and the liquid drops below the required level during operation the cleaning cycle will stop and the following screen will be displayed The QSx will not operate agai...

Страница 16: ...following screen will be displayed If the internal heater exceeds its allowed maximum temperature the following screen will be displayed If the unit overheats due to prolonged use the following messag...

Страница 17: ...press and hold Keys 3 and 4 together The following screen will then appear In order to scroll through the settings available in the Advanced Menu press the MENU key You may exit the Advanced Menu at a...

Страница 18: ...een above shows that the bath has been in use for a total of 2 days 5 hours and 27 minutes Screen 3 Clock The QSx is fitted with a real time clock This is factory set to the correct time and date but...

Страница 19: ...g idle ie when the sonics are not running The QSx can be set to save power when not in use Setting Low Power to ON means that after five minutes of inactivity the QSx ultrasonic bath will enter its SL...

Страница 20: ...sabled for specialist cleaning applications where deionised DI water is used Use the ON and OFF keys to set the Low Level function When the desired option is selected use the MENU key to move to the n...

Страница 21: ...t is therefore the operator s responsibility to ensure that the tank is filled with sufficient water when the liquid level sensor is disabled If the QSx ultrasonic bath operates with insufficient liqu...

Страница 22: ...heater and the ultrasonic generator will turn on irrespective of any other programmed settings You will then be sure that the QSx ultrasonic bath is operating in the mode required for accurate portabl...

Страница 23: ...ass and metals except for aluminium and other soft metals Also suitable for use on medical instruments Ultraclean SA A general purpose cleaning detergent for aluminium and other soft metals Ultraclean...

Страница 24: ...ately useable and will run the cleaning cycle The effect of heat Heating the liquid in the bath will aid the cleaning process Normally a temperature of between 30 to 70 C is sufficient to accelerate t...

Страница 25: ...sing linearly to 50 R H at 40 C Altitude above sea level Up to 2 000 m 6 500 ft Operating Environment Indoor use only Tank External Dimensions mm Tank Internal Dimensions mm Basket Internal Dimensions...

Страница 26: ...egory II Note Mains supply voltage fluctuations are not to exceed 10 of the nominal supply voltage Ultrasonic frequency 32 to 38kHz Heater range 5 to 70 C Working capacity litres Tank capacity max lit...

Страница 27: ...d in the advanced menu see page 19 The screen displays Sonics Low The QSx is fitted with an ultrasonic power detector which monitors the ultrasonic activity in the bath during a cleaning cycle If the...

Страница 28: ...e bath is above 75 C and has aborted the cycle Please allow the liquid to cool or drain some fluid and replace with cooler liquid If your problem persists it may be possible to rectify any issues over...

Страница 29: ...ould be decontaminated packaged in accordance with MHRA guideline document DB2003 5 Management of Medical Devices prior to Repair Service or Investigation This can be found at www mhra gov uk This pol...

Страница 30: ...abrasive causing wear on the metal surface In extreme cases the bath will develop holes and start to leak Portable Appliance Testing should be conducted with water in the bath Service Ultrawave recom...

Страница 31: ...e caused by misuse non observance of maintenance service or connection instructions damage caused by the use of toxic flammable acidic caustic or corrosive chemicals or liquids not recommended by Ultr...

Страница 32: ...nformation and training is now 80 decibels There is also an exposure limit value of 87 decibels taking account of any reduction in exposure provided by hearing protection above which workers must not...

Страница 33: ...ntained by the engineer conducting the service There are no user serviceable parts inside All service and repair should be referred to qualified Ultrawave engineers only Date Cycle count Engineer Deta...

Страница 34: ...ycle count Engineer Details Next service due Date Cycle count Engineer Details Next service due Date Cycle count Engineer Details Next service due Date Cycle count Engineer Details Next service due Da...

Страница 35: ...____ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ ___...

Страница 36: ..._________________________ _______________________________________________ _______________________________________________ _______________________________________________ ______________________________...

Отзывы: