Ultravation UVMATRIX SI Seris Скачать руководство пользователя страница 4

 

 

www.ultravation.com 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Models 

Replacement Lamp 

Part Number 

UVMatrix

TM

 SI-4/G36-HO 

LP-PP-0024 

UVMatrix

TM

 SI-6/G36-HO 

LP-PP-0024 

UVMatrix

TM

 SI-8/G36-HO 

LP-PP-0024 

UVMatrix

TM

 SI-4/G64-HO 

LP-PP-0112 

UVMatrix

TM

 SI-6/G64-HO 

LP-PP-0112 

UVMatrix

TM

 SI-8/G64-HO 

LP-PP-0112 

Troubleshooting: 

 

The Ultravation air disinfection equipment is designed to 
provide many years of trouble free operation. In the unlikely 
event of a problem, please contact your local dealer or 
Ultravation directly. Before calling for service, please be 
sure that: 
 

1.  Unit has 120V or  277V power 
2.  Power disconnect is in the ON position 
3.  Lamps are securely plugged into their sockets

 

 

Please contact your local dealer or Ultravation directly for 
replacement lamps. 
Refer servicing to qualified service personnel. 

Maintenance: 
 

Maintenance typically consists of replacing of the ultraviolet 
lamps every one year. Lamps should be kept clean; time 
intervals required to accomplish this is dependent on the 
application and environment.   
 
UV lamps undergo a photochemical process during 
operation. This slowly reduces the amount of UV light 
generated to disinfect against airborne pathogens. At the 
end of one year, the UV lamps will emit 40% less energy 
than when the lamp was 100 hours old. 
 
When installing new lamps, ensure that the lamp glass is 
free from any fingerprints or debris, as this may alter the 
path of the UV energy. Use rubbing alcohol and a dry cloth 
to remove any surface contaminants. 
 
 
 

 

 

 

                                 

 