![Ultravation UVMATRIX SI Seris Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ultravation/uvmatrix-si-seris/uvmatrix-si-seris_owners-manual_3518837004.webp)
www.ultravation.com
4
Models
Replacement Lamp
Part Number
UVMatrix
TM
SI-4/G36-HO
LP-PP-0024
UVMatrix
TM
SI-6/G36-HO
LP-PP-0024
UVMatrix
TM
SI-8/G36-HO
LP-PP-0024
UVMatrix
TM
SI-4/G64-HO
LP-PP-0112
UVMatrix
TM
SI-6/G64-HO
LP-PP-0112
UVMatrix
TM
SI-8/G64-HO
LP-PP-0112
Troubleshooting:
The Ultravation air disinfection equipment is designed to
provide many years of trouble free operation. In the unlikely
event of a problem, please contact your local dealer or
Ultravation directly. Before calling for service, please be
sure that:
1. Unit has 120V or 277V power
2. Power disconnect is in the ON position
3. Lamps are securely plugged into their sockets
Please contact your local dealer or Ultravation directly for
replacement lamps.
Refer servicing to qualified service personnel.
Maintenance:
Maintenance typically consists of replacing of the ultraviolet
lamps every one year. Lamps should be kept clean; time
intervals required to accomplish this is dependent on the
application and environment.
UV lamps undergo a photochemical process during
operation. This slowly reduces the amount of UV light
generated to disinfect against airborne pathogens. At the
end of one year, the UV lamps will emit 40% less energy
than when the lamp was 100 hours old.
When installing new lamps, ensure that the lamp glass is
free from any fingerprints or debris, as this may alter the
path of the UV energy. Use rubbing alcohol and a dry cloth
to remove any surface contaminants.