Ultravation 92-019 650 CFM Скачать руководство пользователя страница 4

 

4

Installation steps:     

            

 

 
1.

 Determine a suitable location to install the UV-C 

Lamps.  

 
2.

 Select a location for the remote

 

UV lamp module 

assembly. Drill a 1” diameter hole for each lamp 
assembly. Attach lamp module assembly with 2 screws 
at the chosen location, or an optional lamp mounting 
plate, which has been supplied to mount the lamp 
assembly. 

 
Note: The T3 UV lamp assembly can be removed 
independently, simply by removing the 2 screws in 
the lamp holder.

  

 
3.

 Plug the rubber lamp connector fully

 

onto the

 

installed

 

UV lamp assembly. Be sure the 4 pinholes are 

orientated properly to the 4 mating pins of the lamp.  

 
Note: the pins are in a rectangular patent and can 
only be mated in 2 positions.  Pulling the lamp boot 
back will help with the visual alignment of the pins 
and connections.  After making the connection, be 
sure to push lamp boot over lamp base. 
 
See the illustration of the T3 lamp 4-pin connector. 

 

UV-C Germicidal Lamp, Stage 3, Installation 
steps for Models with UVC option. 
           

UV-C Germicidal Stage 3 is designed for installation in 
the HVAC (heating, ventilation, and air conditioning) 
system.  
 
The optimum installation location for UV-C Germicidal 
Stage 3 lamp is in the supply side ductwork exiting the 
HVAC system before the ductwork branches.   
 
The electronics housing should already be installed in the 
previous step; the UVC lamps should be centrally located 
within the air handler and positioned to achieve maximum 
reduction of airborne pathogens.

  

 

Note: 
 

This Photronic System and the UV-C lamps are 
designed to operate constantly and should not cycle 
on and off with a blower motor. Installation in a 
return air duct is acceptable but not recommended in 
a high dust environment. 
 
Do not allow the UVC light to shine on the MERV 11 
filter.  The UVC energy will decompose the filter 
within 120 days.  
 
It is recommended a trained technician install this 
unit. Never look at the UV lights without proper eye 
protection.

 

 
 

Содержание 92-019 650 CFM

Страница 1: ...ication Safety Precautions Power Consumption Installation Requirements Page 3 Installation Filter Housing Cabinet Installation of Electric Power Supply Page 4 Germicidal Lamp Installation Page 5 Maintenance Replacing Filter Page 6 Replacing Photocatalytic Lamps Replacing Germicidal Lamps Page 7 Troubleshooting Warranty Replacement Part Numbers LEAVE FOR HOMEOWNER DC IH 0202 ...

Страница 2: ...rculated through it For maximum filtration effect set your blower to operate continuously Lower speeds allow for higher efficiency Safety Precautions It is recommended that this unit be installed and maintained by a trained technician WARNING UV Hazard Always protect eyes from ultraviolet light NEVER look at UV lamps in operation Unplug or disconnect power before re lamping or servicing WARNING Se...

Страница 3: ...e kept clean This increases air handler component life improves system efficiency and reduces maintenance costs The Ultravation Photronic HEPA Air Cleaner has been designed for use in conjunction with virtually any HVAC system Do not install this unit in the supply duct Be sure to plan adequate space for filter replacement Before installation is complete seal all joints and seams with duct tape or...

Страница 4: ...e illustration of the T3 lamp 4 pin connector UV C Germicidal Lamp Stage 3 Installation steps for Models with UVC option UV C Germicidal Stage 3 is designed for installation in the HVAC heating ventilation and air conditioning system The optimum installation location for UV C Germicidal Stage 3 lamp is in the supply side ductwork exiting the HVAC system before the ductwork branches The electronics...

Страница 5: ...is product It is recommended that this product be serviced and maintained by an HVAC professional MERV or Minimum efficiency rating value is a number assigned to filters indicating their ability to capture particles and dust the higher the number the better the filter A MERV 11 filter is 40 more effective than a MERV 8 Be sure that an Ultravation MERV 11 filter is requested for replacements in thi...

Страница 6: ...mp assembly from the mounting location 5 Reverse the process with new lamps New lamps should be cleaned with a damp cloth or with rubbing alcohol to remove any fingerprints and debris prior to installation TAMPER RESISTANT MOUNTING SCREW 4 REQ D SELF TAPPING MOUNTING SCREWS T3 UV LAMP 2 REQ D LAMP SOCKET T3 LAMP CELL BASE Be sure to recycle the used lamps in accordance with your local codes for fl...

Страница 7: ...is product This warranty gives you specific legal rights and you may also have other rights which vary from state to state All returns must be accompanied by a return authorization number which may be obtained by contacting Ultravation Inc Ultravation Inc P O Box 165 212 Ideal Way Poultney Vermont 05764 Phone 802 287 9735 Fax 802 287 9203 www ultravation com Troubleshooting Important information I...

Отзывы: