Ultravation 92-019 650 CFM Скачать руководство пользователя страница 2

 

2

 

Shipping and Packaging List:                              

 

Filter Housing including Access Door 

 

Merv 11 Media Air Filter  

 HEPA 

Filter 

 

1- Door Handle w/ hardware 

 PCO 

Filter 

 Electrical 

Enclosure 

 

2- 12” T3 UVC Lamps  

 

*2- UVC Lamps Part: 

           12” T3 UVC lamp option 
   

     OR 

                    17” T3 UVC lamp option 

 

*4- 1 inch UVC lamp mounting screws 

 

*8- 1/2 inch 5/16 self tapping screws 

 

*2- UVC Lamp Mounting Plates 

        
* Included when Remote UVC option is purchased 

                                 
Introduction and Applications: 
 

This Ultravation Photronic HEPA Media Air Cleaner is a 
complete whole house air cleaning system.  This high 
efficiency air filtration unit is designed to remove dirt, 
dust, pollen, and microscopic particles: reduce 
unpleasant odors, VOC gases and the microbial 
population from the air that circulates through it. By 
adding this device to your HVAC system, you are 
helping to create a cleaner indoor living environment for 
your whole household. 
 
The system works in 2-3 steps (depending on model 
purchased, some models do not include the germicidal 
protection in step 3)  
 
STEP 1: Trapping particles in the pleats of the MERV 11 
media filter. With an extra large surface area, the filter 
allows for maximum dirt holding capacity and a long, 
useful filter life with minimum air flow restriction. 
 
STEP 2: VOC’s and gases such as the fumes from new 
carpets, paints, nail polish, cigar and cigarette smoke 
are drastically reduced photo chemically via a patented 
process known as photo catalytic conversion or photo 
catalytic oxidation. 
 
(Option)STEP 3: Germicidal UVC light is applied to the 
Air to drastically reduce or eliminate unwanted virus, 
bacteria and mold. 
 
This air cleaner is to be installed in a forced air heating, 
cooling and ventilation system.  It should be installed so 
that all the system’s air is circulated through the filter first 
and VOC Section second. The air cleaner will only filter 
the air that is circulated through it. For maximum filtration 
effect, set your blower to operate continuously. (Lower 
speeds allow for higher efficiency) 

Safety Precautions:                                         

It is recommended that this unit be installed and 
maintained by a trained technician: 

 

WARNING: UV Hazard. Always protect eyes from 
ultraviolet light. NEVER look at UV lamps in 
operation. Unplug or disconnect power before re-
lamping or servicing. 
 
WARNING: Severe eye damage or temporary 
blinding may occur. 
 
WARNING: DO NOT operate UVC lamps outside of 
Air Handler. Mount lamp base to duct first. 
 
WARNING: No openings in duct are allowed which 
would give direct line-of-sight to the UV light. 

 
In the event of accidental breakage or replacement of 
the ultraviolet lamp, please ensure that the lamp is 
disposed of in accordance with local and state 
environmental laws regarding fluorescent lamps 
containing mercury. 

Notice: 

All wiring inside of the duct or air handling system in 
direct line of site of the UV lamp must be shielded with 
aluminum foil tape or equivalent non-combustible 
material. When installing this unit, select a mounting 
location that prevents ultraviolet light exposure to 
plastic flexible duct liner or other plastic components 
with unknown resistance to ultraviolet light. Ultraviolet 
light may cause color shift or structural degradation of 
plastic HVAC components 
 

Power Consumption UV-A, UV-C lamps

 

 

Lamp Type  

Quantity 

Required 

12-inch UVC lamp is 12 watts each   

12-inch UVC lamp is 12 watts each    

17-inch UVC lamp is 22

 

watts each     

 

Installation requirements:

   

 
This unit is designed to be powered up constantly 
and should not cycle on and off with a blower 
motor. 
 

Unit must be installed either within 6 feet of a 120 
power outlet, or hardwired per local and state electrical 
code.   

 

There must be minimum 26 inches in front of the door 
for filter and lamp replacement. 

 
Note:

 Handle fits either door. A Phillips screw driver 

will be required to install the handle. Handle holes are 
behind the label on either door, depending on the 
orientation of the installation.  
 

Содержание 92-019 650 CFM

Страница 1: ...ication Safety Precautions Power Consumption Installation Requirements Page 3 Installation Filter Housing Cabinet Installation of Electric Power Supply Page 4 Germicidal Lamp Installation Page 5 Maintenance Replacing Filter Page 6 Replacing Photocatalytic Lamps Replacing Germicidal Lamps Page 7 Troubleshooting Warranty Replacement Part Numbers LEAVE FOR HOMEOWNER DC IH 0202 ...

Страница 2: ...rculated through it For maximum filtration effect set your blower to operate continuously Lower speeds allow for higher efficiency Safety Precautions It is recommended that this unit be installed and maintained by a trained technician WARNING UV Hazard Always protect eyes from ultraviolet light NEVER look at UV lamps in operation Unplug or disconnect power before re lamping or servicing WARNING Se...

Страница 3: ...e kept clean This increases air handler component life improves system efficiency and reduces maintenance costs The Ultravation Photronic HEPA Air Cleaner has been designed for use in conjunction with virtually any HVAC system Do not install this unit in the supply duct Be sure to plan adequate space for filter replacement Before installation is complete seal all joints and seams with duct tape or...

Страница 4: ...e illustration of the T3 lamp 4 pin connector UV C Germicidal Lamp Stage 3 Installation steps for Models with UVC option UV C Germicidal Stage 3 is designed for installation in the HVAC heating ventilation and air conditioning system The optimum installation location for UV C Germicidal Stage 3 lamp is in the supply side ductwork exiting the HVAC system before the ductwork branches The electronics...

Страница 5: ...is product It is recommended that this product be serviced and maintained by an HVAC professional MERV or Minimum efficiency rating value is a number assigned to filters indicating their ability to capture particles and dust the higher the number the better the filter A MERV 11 filter is 40 more effective than a MERV 8 Be sure that an Ultravation MERV 11 filter is requested for replacements in thi...

Страница 6: ...mp assembly from the mounting location 5 Reverse the process with new lamps New lamps should be cleaned with a damp cloth or with rubbing alcohol to remove any fingerprints and debris prior to installation TAMPER RESISTANT MOUNTING SCREW 4 REQ D SELF TAPPING MOUNTING SCREWS T3 UV LAMP 2 REQ D LAMP SOCKET T3 LAMP CELL BASE Be sure to recycle the used lamps in accordance with your local codes for fl...

Страница 7: ...is product This warranty gives you specific legal rights and you may also have other rights which vary from state to state All returns must be accompanied by a return authorization number which may be obtained by contacting Ultravation Inc Ultravation Inc P O Box 165 212 Ideal Way Poultney Vermont 05764 Phone 802 287 9735 Fax 802 287 9203 www ultravation com Troubleshooting Important information I...