1. Plug the Hand Remote cable into the rear connector marked remote. 

2.Plug the unit into a suitable power source. 

3.Turn the main power switch on and it will illuminate if power is present.

Note:

 For the Hand Remote to work, a valid DMX address must be set from 001 to 511. 

          The display goes to sleep when not in use.  Touching any key once wakens it. DMX control will 
          override the hand remote settings. DMX control is indicated when the valid DMX light is solid RED.

4. The heat up time is approximately 8 minutes before haze can be produced. The Hand Remote indicates the 
    heating cycle when the haze switch light is flashing. When the unit is ready to haze the light will be solid. A 
    three-flash pattern and the fan turning on to full speed indicates an over temperature error. The rear panel     
    Green LED indicates the same status.

5. The haze rate can be switched on, off and varied by using the Hand Remote controls. Haze output increases 
    as the variflow knob turns clockwise.

6. The assist fan is always on low. Fan speed can be increased by rotating the fan knob clockwise. The fan 
    only speeds up during haze output. The Versa Fan Power Port output will also be adjusted.

5. The interval knob is used to provide cycled output. It must be set fully counterclockwise (off) when 
    continuous haze output is required. The hazer will produce 10 seconds of output at the requested flow, spaced 
    by a 1 - 300 seconds interval dependent upon the dial position.
 
6. 15 Minutes prior to shutting down your Radiance Hazer, adjust your haze output setting to “0” Doing this will 
    consume any haze fluid that is still in your distribution feed tubes and processing block. Failure to do so will 
    result in raw fluid being discharged from your output nozzle when you operate it next start-up and will help 
    reduce (not stop) the residue buildup.

Operation with Hand Remote

Haze Switch/
Heating Status LED

Variflow

Fan

Interval

 Hand Held Remote (optional)

5

www.ultratecfx.com

Remote Connector

Heating Status

Green LED

DMX address must be set from 001 to 511

Versa Fan 
Power Port

Содержание Radiance Hazer

Страница 1: ...Radiance Hazer v 102020 Operators Manual...

Страница 2: ...ions 2 Technical Drawings 2 Radiance Setup 3 Operating Procedure 3 Stand Alone Operation 3 DMX Operation 4 RDM Functions 4 Operation with Hand Remote 5 Maintenance Procedure 6 Troubleshooting 6 Recomm...

Страница 3: ...uses only Ultratec Special E ects Luminous 7 Haze Fluid which is a proven uid that o ers the best in low consumption with superior visual hang time It can accommodate both the 2L or 4L sizes of the U...

Страница 4: ...ter Base Haze Fluid Consumption settings from 27 380 cc hour Even lower output is achieved by using the Interval Timer Features 5 Pin USITT DMX 512 RDM Protocol Truss Mount Angle Floor Stand Power Cor...

Страница 5: ...will consume any haze uid that is still in your distribution feed tubes and processing block Failure to do so will result in raw uid being discharged from your output nozzle when you operate it next...

Страница 6: ...LED on the back of the unit indicates heating when ashing and ready when solid A three ash pattern with the fan turning ON to full speed indicates an over temperature error The fan has a minimum sett...

Страница 7: ...tput increases as the vari ow knob turns clockwise 6 The assist fan is always on low Fan speed can be increased by rotating the fan knob clockwise The fan only speeds up during haze output The Versa F...

Страница 8: ...Contact Ultratec Special E ects for more help with this UNIT DOES NOT PRODUCE HAZE 1 Check that uid pick up hose is su ciently submerged into uid in jug 2 Ensure uid pickup line is fully primed with u...

Страница 9: ...the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this reques...

Страница 10: ...Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue He...

Отзывы: