1. Select the desired DMX address on the digital display for the hazer.
Note:
The hazer occupies two sequential DMX addresses. The maximum DMX address of 511 must
be set if using the last two DMX addresses in the chain.
Note:
The display goes to sleep when not in use. Touching any key once wakens it.
The selected address is the Haze rate and the selected a 1 is the fan speed. Control is from
0 - 100% with “0‘’ turning the haze output off and reducing the fan to its minimum default speed. The Versa
Fan Power Port output will also be adjusted.
2. Insert the DMX line into “DMX in”connector.
3. Plug the unit into a suitable power source. Turn the main power switch on and it will illuminate if
power is present. The valid DMX light will be solid when DMX signal is present. The heat up time is
approximately 8 minutes before haze can be produced. The Green LED on the back of the unit
indicates heating when flashing and ready when solid. A three-flash pattern with the fan turning ON
to full speed, indicates an over temperature error.
The fan has a minimum setting and should always run when the power is applied. The fan speed can
only be changed when haze is being produced.
4. 15 Minutes prior to shutting down your Radiance Hazer, adjust your output setting to “0” Doing this
will consume any haze fluid that is still in your distribution feed tubes and processing block. Failure to
do so will result in raw fluid being discharged from your output nozzle when you operate it next start-
up and will help reduce (not stop) the residue buildup
Note: DMX Operation overrides hand held held remote operation controls.
DMX Operation
RDM features will allow remote identify by flashing the DMX display, DMX address changing and machine
temperature monitoring. As well the machine’s group and manufacturer identification data are available.
RDM Functions
www.ultratecfx.com