CABLE LAYOUT

 

Plan the cable layout for both the power and transducer cables.  All cables should be 
adequately secured, protected from physical damage and excessive vibration.  Route cables 
through conduits for additional protection. 

DO NOT CUT AND RE-JOIN TRANSDUCER CABLE.  

If it is necessary to run a transducer cable 

through a bulkhead, a 20mm drill bit or hole saw should be used to accommodate the plug.  
Always check the other side of the bulkhead before drilling to ensure it is clear and safe 
avoiding damage to other items.  Use a rubber grommet to protect the cable from chaffing 
around the area of the hole. 

DO NOT COIL SURPLUS TRANSDUCER CABLE.  

Coiling up cable can affect the output.  Lay 

excess cable out over its own length and tie together. 

 

___________________________________________________________________________

 

CABLE LAYOUT and ELECTRICAL CONNECTIONS 

 

ELECTRICAL CONNECTIONS  

AC VOLTAGE:   

The AC version is supplied with a fixed cable and plug.  The plug can be 

removed if wiring direct onto an AC power supply panel.

 

NOTE:

  the AC power input must be protected by a fuse or circuit breaker rated to 5 amps 

(250v). 

NOTE:  Removing the AC cable from the internal power supply unit will void the warranty.

 

 

DC VOLTAGE:

  

NOTE: 

 the power supply must be a permanent supply to enable the system 

to operate continuously and when the batteries are isolated.

   

Connect the DC (+) cable directly to the battery source, either to the (+) terminal or live 
terminal of the battery switch.  A permanently live (+) BUS Bar can also be used.  The negative 
(-) cable connects to any common 0 volt terminal or BUS Bar. 

NOTE:

  the positive (+) cable must be protected by a fuse or circuit breaker rated to 10 amps. 

DO NOT REVERSE THE POLARITY ON CONNECTION!  The polarity must be checked. 

 

 

 

 

 

 

Brown (+) positive   24v DC 
Blue     (-) negative  0v 

Содержание UltraSystem PowerPlus

Страница 1: ...MARINE GROWTH PREVENTION SYSTEM MGPS Manual ref 29 01 2019 UltraSystem PowerPlus INSTALLATION MANUAL Control unit...

Страница 2: ...W THESE INSTRUCTIONS CAREFULLY This system must be installed in accordance with the instructions in this handbook Failure to do so could result in poor product performance personal injury or damage WA...

Страница 3: ...length of cable supplied which connect the transducers to the control unit Extension cables are available if required in 4 8 and 10m lengths CONTROL UNIT LOCATION CONTROL UNIT INSTALLATION mounting 1...

Страница 4: ...____________________________________ CABLE LAYOUT and ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS AC VOLTAGE The AC version is supplied with a fixed cable and plug The plug can be removed if wiring...

Страница 5: ...4 DC SYSTEM SYSTEM SCHEMATIC DIAGRAM DC...

Страница 6: ...5 AC SYSTEM SYSTEM SCHEMATIC DIAGRAM AC...

Страница 7: ...ove check 3 Check the transducer tight down and no further turn can be made in good contact SWITCHING ON With the installation checked switch on the power supply to the UltraSystem Switch on the Contr...

Страница 8: ...up to 5 seconds both the green and red LED lights will show Note the LED lights are located at the top of the housing their meaning as follows LED 1 ON system is on Light flashes every one second at t...

Страница 9: ...ting for correct operation and the output delivery of 24vdc to the PCB GREEN flashing two flashes followed by ON for 3 seconds Overload on output Check the plugs and cables of the transducers for poss...

Страница 10: ...Serial number NOTES...

Страница 11: ...Ultrasonic Antifouling Ltd Arena Business Centre Holyrood Close Poole Dorset BH17 7FJ England T 44 0 1202 606 185 E info ultrasonic antifouling com www ultrasonic antifouling com...

Отзывы: