THE “BUBBLE MIST” STOPS COMING BACK INTO THE POOL:
Note:
Our suction side installation method requires a portion of the pump‘s power. Anything
affecting the pump‘s performance affects our air draw.
Under normal running conditions, back washing/cleaning the filter restores the “bubble mist”.
Increase the air draw by either adjusting the Dial Flowmeter (on equipped models) counter clock-
wise or resetting the Threaded Rod.
Replacing a worn out pump may be necessary.
Note:
When the outside temperature falls below 50˚F (10˚C), the ultraviolet lamp(s) in your
UltraPure
™
Automatic Water Cleaner
™
may have difficulty starting. The quartz ozone pro-
ducing lamp have mercury vapor inside and the cold temperature causes the mercury to
condense and make the lamp(s) more difficult to start. This occurs in all Ultra Violet Ozone
generators.
Note:
A small amount of condensation may become apparent inside the Dial Flowmeter. This is
normal and does not indicate any malfunction of the Flowmeter or the Ozone generator.
The flowmeter will not read correctly until the condensation has evaporated and the inside
of the flowmeter is dry.