background image

Owner’s Manual and 

Installation Instructions

FOR INGROUND AND 
ABOVE GROUND MODELS

WATER QUALITY INC.

Part

 #

 3704700

UltraPureManual12pg34072.indd   1

UltraPureManual12pg34072.indd   1

24.03.16   15:09

24.03.16   15:09

Содержание Automatic Water Cleaner UPP15

Страница 1: ...ner s Manual and Installation Instructions FOR INGROUND AND ABOVE GROUND MODELS WATER QUALITY INC Part 3704700 UltraPureManual12pg34072 indd 1 UltraPureManual12pg34072 indd 1 24 03 16 15 09 24 03 16 15 09 ...

Страница 2: ...ntee 2 Specifications 3 Installation Location Mounting the UltraPure Water Cleaner Electrical 4 Plumbing Builder Standpipe Install Retrofit Install 5 Installation Instructions 6 External Safety Air Bleed Kit 7 8 Trouble Shooting Repair 9 Terms and Conditions of Warranty UltraPureManual12pg34072 indd 2 UltraPureManual12pg34072 indd 2 24 03 16 15 09 24 03 16 15 09 ...

Страница 3: ...r death The UltraPure Automatic Water Cleaner must be installed in an outdoor location or indoors in a forced air ventilated room Warning Short term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects DO NOT inhale ozone gas produced by this device Ozone is considered toxic above certain concentrations a...

Страница 4: ... free soft to the touch water Easy to manage pool water chemistry and balancing Compatibility with any chlorine source algaecides and minerals The lowest chemical use of any system While Ozone is not a disinfectant to kill algae and bacteria and does not provide a measurable residual it is the best Oxidizer for bather waste removal An UltraPure UV Ozone generator pays for itself while delivering a...

Страница 5: ...nnect the UltraPure Automatic Water Cleaner to the pool timing clock so that the UltraPure operates simultaneously with the pool pump or plug your 120V unit into a grounded receptacle Above ground units come complete with a 120V Piggy back cord The circuit must be protected by a ground fault circuit interrupter G F C I installed in accordance to electrical code Operating your UltraPure Automatic W...

Страница 6: ...e for pressure testing the plumbing When you are ready to install the UltraPure Automatic Water Cleaner cut the cap from the 3 4 standpipe and glue on our 3 4 FSL x 1 4 FPT reducing coupling Apply Teflon tape and screw in the 1 4 MPT x 3 8 straight compression fitting into the reducing coupling The 1 1 2 lb compression check valve is not required and should NOT be used with the method Connect the ...

Страница 7: ...h the metal grippers PRESSURE SIDE VENTURI INSTRUCTIONS kit sold separately See instructions included with the Pool Venturi Conversion Kit Part 1008079 For some applications a pressure side installation may be desired This kit is available for purchase separately ABOVE GROUND INSTALLATION The above ground installation is very similar to the above retrofit installation All above ground units come c...

Страница 8: ...pump or on newer filters which will not evacuate the air See parts package included with your UltraPure Automatic Water Cleaner OPERATION To achieve optimal performance from the UltraPure Automatic Water Cleaner the pool must be as clean as possible to start with Back wash or clean the filters before starting the UltraPure Automatic Water Cleaner Test the pool water and adjust as stated in the cha...

Страница 9: ... the internal air bleed line inside the filter By ensuring this internal air bleed line is as close to the top of the filter as possible air readily escapes as the pump runs Where the External Safety Air Bleed Kit ESABK is installed ensure that it is actually releasing the air being introduced into the filter The pressure gauge port or the manual air bleed port will work well on most filters In so...

Страница 10: ...t lamp s in your UltraPure Automatic Water Cleaner may have difficulty starting The quartz ozone pro ducing lamp have mercury vapor inside and the cold temperature causes the mercury to condense and make the lamp s more difficult to start This occurs in all Ultra Violet Ozone generators Note A small amount of condensation may become apparent inside the Dial Flowmeter This is normal and does not in...

Страница 11: ...e areas c If no ASD is in the area the manufactured goods in need of service should be shipped with RGA to the address on the RGA form freight prepaid Any returned item deemed faulty due to manufacturer defect will be repaired or replaced and shipped back to the customer at no charge to the customer d The owner of the goods may be responsible for all expenses if the field serviced or returned item...

Страница 12: ...1155 Appleby Line Unit E7 Burlington Ontario L7L 5H9 Canada Toll Free 877 281 7603 www waterquality net WATER QUALITY INC Part 3704700 UltraPureManual12pg34072 indd 12 UltraPureManual12pg34072 indd 12 24 03 16 15 09 24 03 16 15 09 ...

Отзывы: