1.2  General Safety Instructions  

 
WARNING:

 

Prior to using the CH0003, please read the safety and caution 

instructions located in this section to prevent the mischarge or catastrophic 
destruction of a battery.  
 

While inherently safe, misuse of the CH0003 may result in damage 

to the battery and/or     the CH0003 battery charger. Specifically: 

 

 

Before using the CH0003 battery charger, read all instructions and 
cautionary markings on (1) the battery charger, (2) battery, (3) product 
using the battery. 

 

 

To reduce the risk of injury, charge only batteries this charger is 
designed to charge: BB-390/U / MAI-390 Nickel Metal - Hydride, 
UBI-2590 / BB-2590/U, UBBL09 Lithium Ion and BB-590/U / MAI-590 
NiCad batteries. Attempting to charge other types of batteries may 
cause personal injury and/or equipment damage.
 

 

 

Do not operate the CH0003 if it has received a sharp blow, been 
dropped, or otherwise damaged in any way; take it to a qualified repair 
technician for servicing. 

 

 

Do not expose the unit to wet conditions (rain or snow) with the lid open. 

 

 

Use of an attachment not recommended or sold by the battery charger 
manufacturer may result in risk of fire, electric shock, or personal injury. 

 

 

To reduce risk of damage to electric plug or cord, pull by plug rather 
than cord when disconnecting charger. 

 

 

Make sure cord(s) is located so that it will not be stepped on, tripped 
over, or otherwise subjected to damage or stress. 

 

 

An extension cord should not be used unless absolutely necessary. Use 
of improper extension cord could result in risk of fire and electric shock. 

 

 

Do not operate the charger with damaged cord or plug—replace it immediately.  

 

 

Do not disassemble the CH0003; take it to a qualified repair technician 
when service or repair is required. Incorrect reassembly may result in a 
risk of electric shock or fire. 

 

 

To reduce risk of electric shock, unplug charger from its power source 
before attempting any maintenance or cleaning. Turning off controls will 
not reduce this risk.  

 

 

If there are any questions regarding maintenance or safety-of-use issues 
pertaining to the CH0003, please contact our service department at: 

 

Service Department 
Ultralife Corporation 
(PHONE) (315) 332-7100   (FAX) (315) 331-7800  
(Email) 

[email protected]

 

 

Содержание CH0003

Страница 1: ...All specific subject to change without notice The information contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Equivalent to NSN 6130 01...

Страница 2: ...bility Information and descriptions contained in this manual are the property of Ultralife Corporation Distribution and or reproduction in part or in whole are expressly forbidden without written cons...

Страница 3: ...7 2 1 6 Wide Range Input Voltage 7 2 1 7 Conditioning Cycle 7 2 1 8 Product Name Plate 7 2 1 9 Equipment Provided 8 2 2 PHYSICAL DESCRIPTION 8 2 3 FUNCTIONAL DESCRIPTION 8 2 3 1 Charge Supply 9 2 3 2...

Страница 4: ...e before proceeding CAUTION Caution statements denote a hazard They identify practices procedures or conditions that could result in damage to or destruction of this product or other equipment or prop...

Страница 5: ...low been dropped or otherwise damaged in any way take it to a qualified repair technician for servicing Do not expose the unit to wet conditions rain or snow with the lid open Use of an attachment not...

Страница 6: ...phic destruction of a battery While inherently safe if the CH0003 is used incorrectly an accident can occur Misuse of the CH0003 may result in damage to the battery and or the CH0003 battery charger 2...

Страница 7: ...nd waits until the battery cools down before going into fast charge If the battery gets above 65 C while charging the charger will suspend the charge until the battery cools down and then go back into...

Страница 8: ...the CH0003 Charger Conditioner is an AC power cable and this technical manual 2 2 Physical Description The CH0003 is 635mm 25 L x 508mm 20 W x 229mm 9 D and weighs approximately 15kg 33 lbs Figure 2...

Страница 9: ...ed The battery detection circuit discharge switches battery charge indicator LEDS and charge circuitry are all located on these boards Each module provides the necessary voltage current parameters to...

Страница 10: ...cations chapter for input power capabilities of the CH0003 WARNING Never alter AC cord or plug provided Improper connection can result in a risk of an electrical shock The temporary adapter should onl...

Страница 11: ...ltralife 6 hours BB 2590 U Lithium ion Bren Tronics 6140 01 490 4316 6 hours UBBL09 Lithium ion Ultralife 6 hours UBBL02 UBI 2590 Lithium ion Ultralife 6140 01 553 3527 6 hours NOTE If a battery type...

Страница 12: ...on contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Page 12 of 16 Figure 3 CH0003 Operation Panel Figure 4 LED Indicators 3 6 1 Green LE...

Страница 13: ...wo green LEDs labeled CHARGING indicate the state of charge a section of the battery is in One indicator is for each section of the battery Solid green Indicates the battery is fast charging Extinguis...

Страница 14: ...sections 4 1 1 Dirt and Dust All external components to the CH0003 can be cleaned with a water dampened non abrasive cloth and allowed to air dry or wipe dry with a clean dry non abrasive cloth 4 1 2...

Страница 15: ...any defect failure or damage caused by improper use or inadequate maintenance and care Ultralife shall not be obligated to provide service under this warranty to repair service or modify these product...

Страница 16: ...5 inches Depth 229mm 9 inches Weight without Battery 15kg 33 lbs Table 2 LED Indicators Indicator Meaning Flashing Green Pre charge Condition Steady Green Fast Charge Green LED Off Fast Charge Complet...

Отзывы: