background image

 

CH0003 Operation Manual 

Newark, New York  |  315-332-7100  |  Fax: 315-331-7800 

©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice 

The information contained herein is for reference only and does not constitute a warrant of performance • 

30 SEP 10 UBI-5156 Rev: G 

 

Page 10 of 16

 

3 OPERATION 

This section provides a basic operational description of the CH0003 battery charger and its 
assemblies/major components. 

3.1  Grounding Connections  

The CH0003 should be grounded to reduce risk of electric shock. The CH0003 is equipped with an 
electric cord having an equipment-grounding conductor and a grounding plug. The plug must be 
plugged into an outlet that is properly installed and grounded in accordance with all local codes and 
ordinances. The CH0003 is also equipped with an external earth ground stud and wing-nut. To 
prevent injury, it is required to use either the AC ground prong or the external ground stud for 
protection. 

3.2 

 AC Power Cord Connections 

If the plug will not fit into the outlet, have a proper outlet installed by a qualified electrician. A 
temporary adapter can be used to connect plug to a two-pole receptacle if a properly grounded 
outlet is not available. (See Specifications chapter for input power capabilities of the CH0003). 

 
WARNING:

 

Never alter AC cord or plug provided. Improper connection can result 

in a risk of an electrical shock. The temporary adapter should only be used until a 
properly grounded outlet can be installed by a qualified electrician. 

 

 

 

WARNING:

 

Before using adapter, ensure the center screw of outlet plate is 

grounded. The green colored rigid ear or lug extending from adapter must be 
connected to a properly grounded outlet.  If necessary, replace original outlet 
cover plate with a longer screw that will secure adapter ear or lug to outlet cover 
plate and make ground connection to outlet.  

 

3.3  Battery Selection, Charging and Charge Cycle 

The CH0003 will charge six batteries at one time (including different battery chemistries or six of the 
same). Each battery’s type will automatically be detected when placed on the charger. The CH0003 
charge module allows the unattended recharge of batteries. The module also assures a safe and 
effective recharge of the battery. The charger has a built-in timer to shut off the CH0003 to prevent 
the battery from being overcharged. The recommended batteries are listed in the table that follows. 

The typical charge cycle for the three types of batteries listed below assumes a fully discharged 
battery for the charge cycle. Note these are average (approximate) times and are listed to show a 
reasonable time frame for the charge cycle. 

 

 

 

 

 

 

Содержание CH0003

Страница 1: ...All specific subject to change without notice The information contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Equivalent to NSN 6130 01...

Страница 2: ...bility Information and descriptions contained in this manual are the property of Ultralife Corporation Distribution and or reproduction in part or in whole are expressly forbidden without written cons...

Страница 3: ...7 2 1 6 Wide Range Input Voltage 7 2 1 7 Conditioning Cycle 7 2 1 8 Product Name Plate 7 2 1 9 Equipment Provided 8 2 2 PHYSICAL DESCRIPTION 8 2 3 FUNCTIONAL DESCRIPTION 8 2 3 1 Charge Supply 9 2 3 2...

Страница 4: ...e before proceeding CAUTION Caution statements denote a hazard They identify practices procedures or conditions that could result in damage to or destruction of this product or other equipment or prop...

Страница 5: ...low been dropped or otherwise damaged in any way take it to a qualified repair technician for servicing Do not expose the unit to wet conditions rain or snow with the lid open Use of an attachment not...

Страница 6: ...phic destruction of a battery While inherently safe if the CH0003 is used incorrectly an accident can occur Misuse of the CH0003 may result in damage to the battery and or the CH0003 battery charger 2...

Страница 7: ...nd waits until the battery cools down before going into fast charge If the battery gets above 65 C while charging the charger will suspend the charge until the battery cools down and then go back into...

Страница 8: ...the CH0003 Charger Conditioner is an AC power cable and this technical manual 2 2 Physical Description The CH0003 is 635mm 25 L x 508mm 20 W x 229mm 9 D and weighs approximately 15kg 33 lbs Figure 2...

Страница 9: ...ed The battery detection circuit discharge switches battery charge indicator LEDS and charge circuitry are all located on these boards Each module provides the necessary voltage current parameters to...

Страница 10: ...cations chapter for input power capabilities of the CH0003 WARNING Never alter AC cord or plug provided Improper connection can result in a risk of an electrical shock The temporary adapter should onl...

Страница 11: ...ltralife 6 hours BB 2590 U Lithium ion Bren Tronics 6140 01 490 4316 6 hours UBBL09 Lithium ion Ultralife 6 hours UBBL02 UBI 2590 Lithium ion Ultralife 6140 01 553 3527 6 hours NOTE If a battery type...

Страница 12: ...on contained herein is for reference only and does not constitute a warrant of performance 30 SEP 10 UBI 5156 Rev G Page 12 of 16 Figure 3 CH0003 Operation Panel Figure 4 LED Indicators 3 6 1 Green LE...

Страница 13: ...wo green LEDs labeled CHARGING indicate the state of charge a section of the battery is in One indicator is for each section of the battery Solid green Indicates the battery is fast charging Extinguis...

Страница 14: ...sections 4 1 1 Dirt and Dust All external components to the CH0003 can be cleaned with a water dampened non abrasive cloth and allowed to air dry or wipe dry with a clean dry non abrasive cloth 4 1 2...

Страница 15: ...any defect failure or damage caused by improper use or inadequate maintenance and care Ultralife shall not be obligated to provide service under this warranty to repair service or modify these product...

Страница 16: ...5 inches Depth 229mm 9 inches Weight without Battery 15kg 33 lbs Table 2 LED Indicators Indicator Meaning Flashing Green Pre charge Condition Steady Green Fast Charge Green LED Off Fast Charge Complet...

Отзывы: