5
Perform the following procedure to program a PreShot in the KD6 Z-Series Dome using a
JPD100, JPD100P, or JPD200P Controller.
JPD100, JPD100P, or JPD200P Controller
a.
Adjust the pan, tilt, zoom, and focus of the KD6 Z-Series Dome
using the joysticks on the
controller until the desired scene is displayed on the monitor.
b.
Press the PreShot number(s),
1-64
, on the numeric keypad.
c.
Press
PRGM
on the function keypad.
d.
Press
Enter
.
The PreShot is stored in the KD6 Z-Series Dome.
4.1.1
Editing PreShots
Follow the procedures for programming PreShots.
4.2
PROGRAMMING VECTORSCANS
VectorScans are one or more PreShots, from the same unit, grouped together and saved with a
number. The amount of time (dwell) the scan remains at each PreShot can be programmed and
saved in the VectorScan. A total of three (1-3) VectorScans are programmable per scan. Each
VectorScan File can contain a maximum of 16 PreShots.
Perform the following procedure to program and store a VectorScan (in the control camera
displayed on the programming controller). Use the worksheet in paragraph 4.3 to log
programmed VectorScans.
Press the
OPT
key.
Press
4
(PROG).
Press
2
(VectorScan
†
).
Enter the
VectorScan # (1-3)
Press
Enter
.
Enter the 1
st
PreShot # (1-64)
.
Press
Enter
.
Enter a
dwell time (0-30 seconds)
.
Press
Enter
.
Enter the
next PreShot # (1-64)
.
Press
Enter
Enter a
dwell time (0-30 seconds)
.
†
Tour (Selection 1) on the JPD Series Controller is not available for the KD6 Z-Series product.