1
KD6 Z-SERIES DOME
OPERATION AND PROGRAMMING
1.0
DESCRIPTION
A KD6 Z-Series Dome consists of:
-
A pan and tilt assembly, often referred to as a "scan".
-
A color camera (NTSC or PAL) with an auto-focus and auto-iris lens.
-
Top
Dome
-
Bottom
Dome
The KD6 Z-Series Dome can be mounted in a dropped ceiling, hard ceiling, indoor pendant
dome, or outdoor weather dome. The bottom domes are designed to blend with building
aesthetics and are available in smoked or clear.
1.1
FEATURES
The scan provides continuous 360
°
pan rotation at rate-proportional controlled speeds. The KD6
Z-Series Dome features manual pan speeds of 1
°
to 180
°
/second and manual tilt speeds of 2
°
to 90
°
/second.
Using a Diamond JPD Series controller, an operator can control the pan and tilt functions and the
lens zoom, focus, and iris functions of the camera lens. The camera lens has auto iris and auto
focus features. The camera lens is a 4m-64mm (16x) zoom lens with a 2X digital magnifier.
The receiver board on the KD6 Z-Series Dome can be programmed to store 64 PreShots and 3
VectorScans. All programming is backed up using a serial EEPROM. This back up prevents
programming from being lost if power is removed from the scan assembly for any reason.
2.0
ADDRESSING
Each KD6 Z-Series Dome must be given a unique system address. This address is the camera
number an operator uses to call-up and control the dome.
A JPD Series Controller (JPD-101, JPD-100, JPD-200P, JPD-100P) is used to set the address of
a KD6 Z-Series Dome. You must know the 8-digit serial number of the unit
. The serial number
is located on the side of the mounting bracket of the pan and tilt assembly.
Press
OPT
on the JPD controller to view the LCD menu options
OPT
Press
1
(MISC)
1
Press
2
(SET ADD) to set the address
2
Enter the
Serial Number
(8 digits) of the KD6 Z-Series Dome (SN-)
SN#
Enter the leading character A of the serial number as a 0
*
.
Press
Enter
.
Enter
Enter the desired
system address
(camera number) of the dome (
1-250
)
###
Press
Enter.
Enter
The LCD on the controller displays the message, “Updating Address”.
*
Input Serial Number (S/N:) A1012585 as 01012585.