UltraGlow G36D Скачать руководство пользователя страница 44

UltraGlow  G36D Zero Clearance Direct Vent Gas Fireplace

44

Installer: Please complete the following information

Dealer Name & Address: ______________________________________________
___________________________________________________________________
Installer: ___________________________________________________________
Phone #: ___________________________________________________________
Date Installed: ______________________________________________________
Serial No.: __________________________________________________________

Register your UltraGlow

®

Register your UltraGlow

Register your UltraGlow  online at

®

®

http://www.regency-fi re.com

© Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.

Содержание G36D

Страница 1: ...ly for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used FOR YOUR SAFETY What to do if you smell gas Do no...

Страница 2: ...AT HIGH ATLITUDES CAN CGA 2 17 M91 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety...

Страница 3: ...ments 6 Locating Your Gas Stove 6 Clearances 7 Mantel Leg Clearances 7 Framing And Finishing 7 Combustible Mantels 8 Unit Assembly Prior To Installation 9 Venting Introduction 9 Exterior Vent Terminat...

Страница 4: ...Btu h 3 96 kW 0 4500 ft pi 0 1372 m 26 000 B 7 91 tu h kW APPAREIL FONCTIONNANT AU NATURAL GAZ CONCU POUR ETRE POELE Pression d allimentation minimum Pression la tubulure d chappement lev e Pression l...

Страница 5: ...rvent to another room or inside a building Make sure that the vent is tted as per Venting instructions 5 Inspect the venting system annually for blockage and any signs of deterioration 6 Venting termi...

Страница 6: ...other than wood ooring the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 4 The G36D Direct Vent Gas Fireplace can be installedinarecessedpos...

Страница 7: ...Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Alcove Clearances Max Depth 36 914mm Min Width 48 1219mm Min Height 72 1829mm see mantl...

Страница 8: ...learances from top of unit are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Th...

Страница 9: ...side nailing strip using 3 screws VENTING INTRODUCTION The G36D uses the balanced ue technology Co Axial system The inner liner vents products of combustion to the outside while the outer liner draws...

Страница 10: ...r with AstroCap Termination Cap min 6 15cm with Dura Vent Termination Cap 12 30cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator...

Страница 11: ...cations section UltraGlow UltraGlow UltraGlow Direct Vent Flex Termination Kit Part 946 515 includes all the parts Direct Vent Flex Termination Kit Part 946 515 includes all the parts needed to instal...

Страница 12: ...45O Elbow Galvinized 945 4DT EL45 4D45L 45O Elbow Black 945B 4DT EL45B 4D45LB 45O Elbow Swivel Galvinized 945G N A N A 45O Elbow Swivel Black 945BG N A N A 90O Elbow Galvinized 990 4DT EL90S 4D90LS 9...

Страница 13: ...nation Caps When using Rigid Vent piping other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCapTM and FPI Riser Vent terminal are certi ed for installation...

Страница 14: ...gid vent systems All Rigid Pipe Systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter UltraGlow UltraGlow UltraGlow UltraGlow Flex Vent Flex Vent 4 inner diameter 6 7 8 inner diameter M...

Страница 15: ...orizontal termination arrangements by using chart in the Rigid Pepi Venting Arrangements Vertical Termination section and deducting 3 ft 0 9m from the maximum horizontal distance for the second 90o el...

Страница 16: ...aight vertical including a maximum 20 0 5m horizontal offset using two 90o elbow two 45o elbows equal one 90o elbow with Rigid Pipe vent systems for Propane and Natural Gas as per diagram 2 Vent must...

Страница 17: ...The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for Propane and Natural Gas Maximum two 45o elb...

Страница 18: ...DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor...

Страница 19: ...nt Gas Fireplace 19 INSTALLATION VENTING ARRANGEMENTS VERTICAL TERMINATIONS with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams s...

Страница 20: ...esigned to slide straight onto the male ends of adjacent pipes and ttings by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends Diagram1 Pushthepi...

Страница 21: ...at ceiling or wall cut a 10inchsquarehole Frametheholeasshown in Diagram 3 and install the restop 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow connections are in t...

Страница 22: ...or UltraGlow Direct Vent Direct Vent System Flex 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the...

Страница 23: ...ng around the thermopile 1 around the thermocouple and 1 owing across the burner it does not have to be touching the burner Note Ifyouhaveanincorrect amepattern contact your Regency dealer for further...

Страница 24: ...ntil it is free and extract it 13 Check that the screw is clean and if necessary remove dirt 14 Flip the screw Fig 3 Fig 1 Fig 2 Fig 3 8 Remove burner ori ce with a 1 2 wrench and discard Use another...

Страница 25: ...rted to LPG near or on top of the serial decal Installation of the DC Sparker 15 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 4 Fig 4 21 Locate...

Страница 26: ...re into place with the velcro which is provided in the kit Heat Shield 29 Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield 34 Tie up the loose w...

Страница 27: ...force into position 3 Place Log 02 75 on the rear log support pins with the at side to the back The 02 refer numbers i e 02 75 are molded into the rear of each log 02 52 02 54 Notch a 02 75 Rear Log b...

Страница 28: ...utouts 8 PlaceLog02 52betweenLogs02 51and02 75andontheindentation on Log 02 54 The bottom right end sits behind the rear grate tab Front Brackets Notch 9 Sit Log 02 50 on the front left side of the bu...

Страница 29: ...make sure ame ows smoothly from one end of burner to the other If there is any ame hesitation check that area for any blockage of the burner ports 12 Install ush glass as per instructions in manual Do...

Страница 30: ...to side 2 The bottom louver has a hinge that is attached 2 screws per hinge to the lip on bottom of the unit 3 Open the bottom louver Pull the Burner ON OFF control box from inside the bottom of the r...

Страница 31: ...nient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the replace to that location Use the Thermostat Wire Table 2 Con...

Страница 32: ...e of a power failure the burner switch and the optional remote control thermostat will continue to operate Do not cut the ground terminal off under any circumstances Caution Ensure that the wires do n...

Страница 33: ...ire extra space to slide the fan to the back the left spring can be unhooked from the bracket Note A 120 Volt AC power cord can be installed at rough in stage so that the power is available A three wi...

Страница 34: ...curing process To ensure that the paint is properly cured it is recommended that you burn your replace for at least four 4 hours the rst time before you use it with the fan on When rst operated the u...

Страница 35: ...explosion D Do not use this appliance if any part has been under water Immediately call a quali ed service technician to inspect the appliance and to replace any part of the control system and any gas...

Страница 36: ...nish and void the warranty Clean any ngerprints off before turning the unit on If the top louvers start to discolour check the door gasket seal and replace if necessary LOG REPLACEMENT The unit shoul...

Страница 37: ...embly Note Failure to install a new gasket may severely affect the appliance performance 9 Reinstall the 12 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the va...

Страница 38: ...04 687 Clamp Connector 20 510 033 Top Nailing Strip 21 510 064 Side Nailing Strip 23 780 011 Standoff Top 24 780 013 Standoff Side Back Part Description 27 Outer Flue Collar 28 Inner Flue Collar Assy...

Страница 39: ...S I T Natural Gas 910 380 Valve S I T Propane 58 Valve Bracket 65 Pilot Bracket 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Ga...

Страница 40: ...lush Glass Trim Set Brass 510 947 Flush Glass Trim Set Steel 510 932 Flush Glass Trim Set Gold 132 904 196 Magnet 1 Round 133 780 069 Flush Louver Top Black 134 786 520 Assembly Bottom Black 135 940 3...

Страница 41: ...____________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______________...

Страница 42: ...___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________________________...

Страница 43: ...s At all times FPI reserves the right to inspect product in the eld which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitte...

Страница 44: ...__________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No ___...

Отзывы: